Abstract: In the present study, Convective heat transfer
coefficient and pressure drop of Al2O3/water nanofluid in laminar
flow regime under constant heat flux conditions inside a circular tube
were experimentally investigated. Al2O3/water nanofluid with 0.5%
and 1% volume concentrations with 15 nm diameter nanoparticles
were used as working fluid. The effect of different volume
concentrations on convective heat transfer coefficient and friction
factor was studied. The results emphasize that increasing of particle
volume concentration leads to enhance convective heat transfer
coefficient. Measurements show the average heat transfer coefficient
enhanced about 11-20% with 0.5% volume concentration and
increased about 16-27% with 1% volume concentration compared to
distilled water. In addition, the convective heat transfer coefficient of
nanofluid enhances with increase in heat flux. From the results, the
average ratio of (fnf/fbf) was about 1.10 for 0.5% volume
concentration. Therefore, there is no significant increase in friction
factor for nanofluids.
Abstract: Air emissions from waste treatment plants often
consist of a combination of Volatile Organic Compounds (VOCs)
and odors. Hydrogen sulfide is one of the major odorous gases
present in the waste emissions coming from municipal wastewater
treatment facilities. Hydrogen sulfide (H2S) is odorous, highly toxic
and flammable. Exposure to lower concentrations can result in eye
irritation, a sore throat and cough, shortness of breath, and fluid in
the lungs. Biofiltration has become a widely accepted technology for
treating air streams containing H2S. When compared with other nonbiological
technologies, biofilter is more cost-effective for treating large
volumes of air containing low concentrations of biodegradable compounds.
Optimization of biofilter media is essential for many reasons such as:
providing a higher surface area for biofilm growth, low pressure drop,
physical stability, and good moisture retention. In this work, a novel
biofilter media is developed and tested at a pumping station of a
municipality located in the United Arab Emirates (UAE). The
media is found to be very effective (>99%) in removing H2S
concentrations that are expected in pumping stations under steady
state and shock loading conditions.
Abstract: Modeling of a heterogeneous industrial fixed bed
reactor for selective dehydrogenation of heavy paraffin with Pt-Sn-
Al2O3 catalyst has been the subject of current study. By applying
mass balance, momentum balance for appropriate element of reactor
and using pressure drop, rate and deactivation equations, a detailed
model of the reactor has been obtained. Mass balance equations have
been written for five different components. In order to estimate
reactor production by the passage of time, the reactor model which is
a set of partial differential equations, ordinary differential equations
and algebraic equations has been solved numerically.
Paraffins, olefins, dienes, aromatics and hydrogen mole percent as
a function of time and reactor radius have been found by numerical
solution of the model. Results of model have been compared with
industrial reactor data at different operation times. The comparison
successfully confirms validity of proposed model.
Abstract: This study deals with Computational Fluid Dynamics
(CFD) studies of the interactions between the air flow and louvered
fins which equipped the automotive heat exchangers. 3D numerical
simulation results are obtained by using the ANSYS Fluent 13.0 code
and compared to experimental data. The paper studies the effect of
louver angle and louver pitch geometrical parameters, on overall
thermal hydraulic performances of louvered fins.
The comparison between CFD simulations and experimental data
show that established 3-D CFD model gives a good agreement. The
validation agrees, with about 7% of deviation respectively of friction
and Colburn factors to experimental results. As first, it is found that
the louver angle has a strong influence on the heat transfer rate. Then,
louver angle and louver pitch variation of the louvers and their effects
on thermal hydraulic performances are studied. In addition to this
study, it is shown that the second half of the fin takes has a
significant contribution on pressure drop increase without any
increase in heat transfer.
Abstract: In the present study, the pressure drop and laminar convection heat transfer characteristics of nanofluids in microchannel heat sink with square duct are numerically investigated. The water based nanofluids created with Al2O3 and CuO particles in four different volume fractions of 0%, 0.5%, 1%, 1.5% and 2% are used to analyze their effects on heat transfer and the pressure drop. Under the laminar, steady-state flow conditions, the finite volume method is used to solve the governing equations of heat transfer. Mixture Model is considered to simulate the nanofluid flow. For verification of used numerical method, the results obtained from numerical calculations were compared with the results in literature for both pure water and the nanofluids in different volume fractions. The distributions of the particles in base fluid are assumed to be uniform. The results are evaluated in terms of Nusselt number, the pressure drop and heat transfer enhancement. Analysis shows that the nanofluids enhance heat transfer while the Reynolds number and the volume fractions are increasing. The best overall enhancement was obtained at φ=%2 and Re=100 for CuO-water nanofluid.
Abstract: CFD simulations are carried out in arterial stenoses
with 48 % areal occlusion. Non-newtonian fluid model is selected for
the blood flow as the same problem has been solved before with
Newtonian fluid model. Studies on flow resistance with the presence
of surface irregularities are carried out. Investigations are also
performed on the pressure drop at various Reynolds numbers. The
present study revealed that the pressure drop across a stenosed artery
is practically unaffected by surface irregularities at low Reynolds
numbers, while flow features are observed and discussed at higher
Reynolds numbers.
Abstract: Water recycling represents an important challenge for many countries, in particular in countries where this natural resource is rare. On the other hand, in many operations, water is used as a cooling medium, as a high proportion of water consumed in industry is used for cooling purposes. Generally this water is rejected directly to the nature. This reject will cause serious environment damages as well as an important waste of this precious element.. On way to solve these problems is to reuse and recycle this warm water, through the use of natural cooling medium, such as air in a heat exchanger unit, known as a cooling tower. A poor performance, design or reliability of cooling towers will result in lower flow rate of cooling water an increase in the evaporation of water, an hence losses of water and energy. This paper which presents an experimental investigate of thermal and hydraulic performances of a mechanical cooling tower, enables to show that the water evaporation rate, Mev, increases with an increase in the air and water flow rates, as well as inlet water temperature and for fixed air flow rates, the pressure drop (ΔPw/Z) increases with increasing , L, due to the hydrodynamic behavior of the air/water flow.
Abstract: In the present study, a steady-state simulation model
has been developed to evaluate the system performance of a
transcritical carbon dioxide heat pump system for simultaneous water
cooling and heating. Both the evaporator (including both two-phase
and superheated zone) and gas cooler models consider the highly
variable heat transfer characteristics of CO2 and pressure drop. The
numerical simulation model of transcritical CO2 heat pump has been
validated by test data obtained from experiments on the heat pump
prototype. Comparison between the test results and the model
prediction for system COP variation with compressor discharge
pressure shows a modest agreement with a maximum deviation of
15% and the trends are fairly similar. Comparison for other operating
parameters also shows fairly similar deviation between the test
results and the model prediction. Finally, the simulation results are
presented to study the effects of operating parameters such as,
temperature of heat exchanger fluid at the inlet, discharge pressure,
compressor speed on system performance of CO2 heat pump, suitable
in a dairy plant where simultaneous cooling at 4oC and heating at
73oC are required. Results show that good heat transfer properties of
CO2 for both two-phase and supercritical region and efficient
compression process contribute a lot for high system COPs.
Abstract: The Non-Rotating Adjustable Stabilizer / Directional
Solution (NAS/DS) is the imitation of a mechanical process or an
object by a directional drilling operation that causes a respond
mathematically and graphically to data and decision to choose the
best conditions compared to the previous mode.
The NAS/DS Auto Guide rotary steerable tool is undergoing final
field trials. The point-the-bit tool can use any bit, work at any
rotating speed, work with any MWD/LWD system, and there is no
pressure drop through the tool. It is a fully closed-loop system that
automatically maintains a specified curvature rate.
The Non–Rotating Adjustable stabilizer (NAS) can be controls
curvature rate by exactly positioning and run with the optimum bit,
use the most effective weight (WOB) and rotary speed (RPM) and
apply all of the available hydraulic energy to the bit. The directional
simulator allowed to specify the size of the curvature rate
performance errors of the NAS tool and the magnitude of the random
errors in the survey measurements called the Directional Solution
(DS).
The combination of these technologies (NAS/DS) will provide
smoother bore holes, reduced drilling time, reduced drilling cost and
incredible targeting precision. This simulator controls curvature rate
by precisely adjusting the radial extension of stabilizer blades on a
near bit Non-Rotating Stabilizer and control process corrects for the
secondary effects caused by formation characteristics, bit and tool
wear, and manufacturing tolerances.
Abstract: Gas hydrates can agglomerate and block multiphase oil and gas pipelines when water is present at hydrate forming conditions. Using "Cold Flow Technology", the aim is to condition gas hydrates so that they can be transported as a slurry mixture without a risk of agglomeration. During the pipeline shut down however, hydrate particles may settle in bends and build hydrate plugs. An experimental setup has been designed and constructed to study the flow of such plugs at start up operations. Experiments have been performed using model fluid and model hydrate particles. The propagations of initial plugs in a bend were recorded with impedance probes along the pipe. The experimental results show a dispersion of the plug front. A peak in pressure drop was also recorded when the plugs were passing the bend. The evolutions of the plugs have been simulated by numerical integration of the incompressible mass balance equations, with an imposed mixture velocity. The slip between particles and carrier fluid has been calculated using a drag relation together with a particle-fluid force balance.
Abstract: With the growth of electricity generation from gas
energy gas pipeline reliability can substantially impact the electric
generation. A physical disruption to pipeline or to a compressor
station can interrupt the flow of gas or reduce the pressure and lead
to loss of multiple gas-fired electric generators, which could
dramatically reduce the supplied power and threaten the power
system security. Gas pressure drops during peak loading time on
pipeline system, is a common problem in network with no enough
transportation capacity which limits gas transportation and causes
many problem for thermal domain power systems in supplying their
demand. For a feasible generation scheduling planning in networks
with no sufficient gas transportation capacity, it is required to
consider gas pipeline constraints in solving the optimization problem
and evaluate the impacts of gas consumption in power plants on gas
pipelines operating condition. This paper studies about operating of
gas fired power plants in critical conditions when the demand of gas
and electricity peak together. An integrated model of gas and electric
model is used to consider the gas pipeline constraints in the economic
dispatch problem of gas-fueled thermal generator units.
Abstract: Circle grid space filling plate is a flow conditioner with a fractal pattern and used to eliminate turbulence originating from pipe fittings in experimental fluid flow applications. In this paper, steady state, incompressible, swirling turbulent flow through circle grid space filling plate has been studied. The solution and the analysis were carried out using finite volume CFD solver FLUENT 6.2. Three turbulence models were used in the numerical investigation and their results were compared with the pressure drop correlation of BS EN ISO 5167-2:2003. The turbulence models investigated here are the standard k-ε, realizable k-ε, and the Reynolds Stress Model (RSM). The results showed that the RSM model gave the best agreement with the ISO pressure drop correlation. The effects of circle grids space filling plate thickness and Reynolds number on the flow characteristics have been investigated as well.
Abstract: The research focuses on the effects of polyphenols
extracted from Sambucus nigra fruit, using an experimental arterial
hypertension pattern, as well as their influence on the oxidative
stress. The results reveal the normalization of the reduced glutathion
concentration, as well as a considerable reduction in the
malondialdehide serum concentration by the polyphenolic protection.
The rat blood pressure values were recorded using a CODATM
system, which uses a non-invasive blood pressure measuring method.
All the measured blood pressure components revealed a biostatistically
significant (p
Abstract: Gas condensate Reservoirs show complicated thermodynamic behavior when their pressure reduces to under dew point pressure. Condensate blockage around the producing well cause significant reduction of production rate as well bottom-hole pressure drops below saturation pressure. The main objective of this work was to examine the well test analysis of naturally fractured lean gas condensate reservoir and investigate the effect of condensate formed around the well-bore on behavior of single phase pseudo pressure and its derivative curves. In this work a naturally fractured lean gas condensate reservoir is simulated with compositional simulator. Different sensitivity analysis done on Corry parameters and result of simulator is feed to analytical well testing software. For consideration of these phenomena eighteen compositional models with Capillary number effect are constructed. Matrix relative permeability obeys Corry relative permeability and relative permeability in fracture is linear. Well testing behavior of these models are studied and interpreted. Results show different sensitivity analysis on relative permeability of matrix does not have strong effect on well testing behavior even most part of the matrix around the well is occupied with condensate.
Abstract: Tread design has evolved over the years to achieve the common tread pattern used in current vehicles. However, to meet safety and comfort requirements, tread design considers more than one design factor. Tread design must consider the grip and drainage, and the manner in which to reduce rolling noise, which is one of the main factors considered by manufacturers. The main objective of this study was the application the computational fluid dynamics (CFD) technique to simulate the contact surface of the tire and ground. The results demonstrated an air-Pumping and large pressure drop effect in the process of contact surface. The results also revealed that the pressure can be used to analyze sound pressure level (SPL).
Abstract: Reciprocating compressors are flexible to handle wide capacity and condition swings, offer a very efficient method of compressing almost any gas mixture in wide range of pressure, can generate high head independent of density, and have numerous applications and wide power ratings. These make them vital component in various units of industrial plants. In this paper optimum reciprocating compressor configuration regarding interstage pressures, low suction pressure, non-lubricated cylinder, speed of machine, capacity control system, compressor valve, lubrication system, piston rod coating, cylinder liner material, barring device, pressure drops, rod load, pin reversal, discharge temperature, cylinder coolant system, performance, flow, coupling, special tools, condition monitoring (including vibration, thermal and rod drop monitoring), commercial points, delivery and acoustic conditions are presented.
Abstract: This paper presents a unified approach based graph
theory and system theory postulates for the modeling and analysis
of Simple open cycle Gas turbine system. In the present paper, the
simple open cycle gas turbine system has been modeled up to its subsystem
level and system variables have been identified to develop the
process subgraphs. The theorems and algorithms of the graph theory
have been used to represent behavioural properties of the system like
rate of heat and work transfers rates, pressure drops and temperature
drops in the involved processes of the system. The processes have
been represented as edges of the process subgraphs and their limits
as the vertices of the process subgraphs. The system across variables
and through variables has been used to develop terminal equations of
the process subgraphs of the system. The set of equations developed
for vertices and edges of network graph are used to solve the system
for its process variables.