Abstract: Water hammer is a hydraulic transient problem which is commonly encountered in the penstocks of hydropower plants. The numerical model was developed to estimate the transient behavior of pressure waves in pipe systems. The computational algorithm was proposed to model the water hammer phenomenon in a pipe system with pump shutdown at midstream and sudden valve closure at downstream. To predict the pressure head and flow velocity as a function of time as a result of rapidly closing a valve and pump shutdown, two boundary conditions at the ends considering pump operation and valve control can be implemented as specified equations of the pressure head and flow velocity based on the characteristics method. It was shown that the effects of transient flow make it determine the needs for protection devices, such as surge tanks, surge relief valves, or air valves, at various points in the system against overpressure and low pressure. It produced reasonably good performance with the results of the proposed transient model for pipeline systems. The proposed numerical model can be used as an efficient tool for the safety assessment of hydropower plants due to water hammer.
Abstract: This paper presents the problem of modeling and simulating of transient phenomena in conveying pipeline systems based on the rigid column and full elastic methods. Transient analysis is important and one of the more challenging and complicated flow problem in the design and the operation of water pipeline systems. Transient can produce large pressure forces and rapid fluid acceleration into a water pipeline system, these disturbances may result in device failures, system fatigue or pipe ruptures, and even the dirty water intrusion. Several methods have been introduced and used to analyze transient flow, an accurate analysis and suitable protection devices should be used to protect water pipeline systems. The fourth-order Runge-Kutta method has been used to solve the dynamic and continuity equations in the rigid column method, while the characteristics method used to solve these equations in the full elastic method. The results obtained provide that the model is an efficient tool for flow transient analysis and provide approximately identical results by using these two methods. Moreover; using the simple surge tank ”open surge tank” reduces the unfavorable effects of transients.
Abstract: Genetic Algorithm (GA) is a powerful technique for solving optimization problems. It follows the idea of survival of the fittest - Better and better solutions evolve from previous generations until a near optimal solution is obtained. GA uses the main three operations, the selection, crossover and mutation to produce new generations from the old ones. GA has been widely used to solve optimization problems in many applications such as traveling salesman problem, airport traffic control, information retrieval (IR), reactive power optimization, job shop scheduling, and hydraulics systems such as water pipeline systems. In water pipeline systems we need to achieve some goals optimally such as minimum cost of construction, minimum length of pipes and diameters, and the place of protection devices. GA shows high performance over the other optimization techniques, moreover, it is easy to implement and use. Also, it searches a limited number of solutions.
Abstract: Desurging tank with automatic air control “DTAAC” is a water hammer protection device, operates either an open or closed surge tank according to the water level inside the surge tank, with the volume of air trapped in the filling phase, this protection device has the advantages of its easy maintenance, and does not need to run any external energy source (air compressor). A computer program has been developed based on the characteristic method to simulate flow transient phenomena in pressurized water pipeline systems, it provides the influence of using the protection devices to control the adverse effects due to excessive and low pressure occurring in this phenomena. The developed model applied to a simple main water pipeline system: pump combined with DTAAC connected to a reservoir. The results obtained provide that the model is an efficient tool for water hammer analysis. Moreover; using the DTAAC reduces the unfavorable effects of the transients.
Abstract: The primary objectives of transient analysis are to determine the values of transient pressures that can result from flow control operations and to establish the design criteria for system equipment and devices (such as control devices and pipe wall thickness) so as to provide an acceptable level of protection against system failure due to pipe collapse or bursting. Because of the complexity of the equations needed to describe transients, numerical computer models are used to analyze transient flow hydraulics. An effective numerical model allows the hydraulic engineer to analyze potential transient events and to identify and evaluate alternative solutions for controlling hydraulic transients, thereby protecting the integrity of the hydraulic system. This paper presents the influence of using the protection devices to control the adverse effects due to excessive and low pressure occurs in the transient.
Abstract: Fluid transient analysis is one of the more challenging and complicated flow problems in the design and the operation of water pipeline systems (wps). When transient conditions "water hammer" exists, the life expectancy of the wps can be adversely impacted, resulting in pump and valve failures and catastrophic pipe ruptures. Transient control has become an essential requirement for ensuring safe operation of wps. An accurate analysis and suitable protection devices should be used to protect wps. This paper presents the problem of modeling and simulation of transient phenomena in wps based on the characteristics method. Also, it provides the influence of using the protection devices to control the adverse effects due to excessive and low pressure occur in the transient. The developed model applied for main wps: pump combined with closed surge tank connected to a reservoir. The results obtained provide that the model is an efficient tool for water hammer analysis. Moreover; using the closed surge tank reduces the unfavorable effects of transients.
Abstract: In water pipeline systems, the flow control is an integrated part of the operation, for instance, opening and closing the valves, starting and stopping the pumps, when these operations very quickly performed, they shall cause the hydraulic transient phenomena, which may cause pump and, valve failures and catastrophic pipe ruptures. Fluid transient analysis is one of the more challenging and complicated flow problems in the design and the operation of water pipeline systems. Transient control has become an essential requirement for ensuring safe operation of water pipeline systems. An accurate analysis and suitable protection devices should be used to protect water pipeline systems. The fourth-order Runge-Kutta method has been used to solve the dynamic and continuity equations in the rigid column method, while the characteristics method used to solve these equations in the full elastic methods. This paper presents the problem of modeling and simulating of transient phenomena in conveying pipeline systems based on the rigid column and full elastic methods. Also, it provides the influence of using the protection devices to protect the pipeline systems from damaging due to the gain pressure which occur in the transient state. The results obtained provide that the model is an efficient tool for flow transient analysis and provide approximately identical results by using these two methods. Moreover; using the closed surge tank reduces the unfavorable effects of transients.
Abstract: This paper presents a novel three-phase utility
frequency to high frequency soft switching power conversion circuit
with dual mode pulse width modulation and pulse density modulation
for high power induction heating applications as melting of steel and
non ferrous metals, annealing of metals, surface hardening of steel
and cast iron work pieces and hot water producers, steamers and
super heated steamers. This high frequency power conversion circuit
can operate from three-phase systems to produce high current for
high power induction heating applications under the principles of
ZVS and it can regulate its ac output power from the rated value to a
low power level. A dual mode modulation control scheme based on
high frequency PWM in synchronization with the utility frequency
positive and negative half cycles for the proposed high frequency
conversion circuit and utility frequency pulse density modulation is
produced to extend its soft switching operating range for wide ac
output power regulation. A dual packs heat exchanger assembly is
designed to be used in consumer and industrial fluid pipeline systems
and it is proved to be suitable for the hot water, steam and super
heated steam producers. Experiment and simulation results are given
in this paper to verify the operation principles of the proposed ac
conversion circuit and to evaluate its power regulation and
conversion efficiency. Also, the paper presents a mutual coupling
model of the induction heating load instead of equivalent transformer
circuit model.
Abstract: If an unsteady heat transfer or heat impulse happens in
part of the cryogenic pipeline system of large space environment
simulation equipment while running in vacuum environment, it will
lead to abnormal flow of the cryogenic fluid in the pipeline. When the
situation gets worse, the cryogenic fluid in the pipeline will have phase
change and a gas block which results in the malfunction of the
cryogenic pipeline system. Referring to the structural parameter of a
typical cryogenic pipeline system and the basic equation, an analytical
model and a calculation model for cryogenic pipeline system can be
built. The various factors which influence the thermal resistance of a
cryogenic pipeline system can be analyzed and calculated by using the
qualitative analysis relation deduced for thermal resistance of pipeline.
The research conclusion could provide theoretical support for the
design and operation of a cryogenic pipeline system
Abstract: Tubular linear induction motor (TLIM) can be used as a capsule pump in a large pneumatic capsule pipeline (PCP) system. Parametric performance evaluation of the designed 1-meter diameter PCP-TLIM system yields encouraging results for practical implementation. The capsule thrust and speed inside the TLIM pump can be calculated from the combination of the PCP fluid mechanics and the TLIM equations. The TLIM equivalent circuits derived from those of the conventional three-phase induction motor are used as a model to predict the static test results of a small-scale PCP-TLIM system. In this paper, additional dynamic tests are performed on the same small-scale PCP-TLIM system with two capsules of different diameters. The behaviors of the capsule inside the pump are observed and analyzed. The dynamic performances from the dynamic tests are compared with the theoretical predictions based on the TLIM equivalent circuit model.
Abstract: To explore pipelines is one of various bio-mimetic
robot applications. The robot may work in common buildings such as
between ceilings and ducts, in addition to complicated and massive
pipeline systems of large industrial plants. The bio-mimetic robot finds
any troubled area or malfunction and then reports its data. Importantly,
it can not only prepare for but also react to any abnormal routes in the
pipeline. The pipeline monitoring tasks require special types of mobile
robots. For an effective movement along a pipeline, the movement of
the robot will be similar to that of insects or crawling animals. During
its movement along the pipelines, a pipeline monitoring robot has an
important task of finding the shapes of the approaching path on the
pipes. In this paper we propose an effective solution to the pipeline
pattern recognition, based on the fuzzy classification rules for the
measured IR distance data.
Abstract: With the growth of electricity generation from gas
energy gas pipeline reliability can substantially impact the electric
generation. A physical disruption to pipeline or to a compressor
station can interrupt the flow of gas or reduce the pressure and lead
to loss of multiple gas-fired electric generators, which could
dramatically reduce the supplied power and threaten the power
system security. Gas pressure drops during peak loading time on
pipeline system, is a common problem in network with no enough
transportation capacity which limits gas transportation and causes
many problem for thermal domain power systems in supplying their
demand. For a feasible generation scheduling planning in networks
with no sufficient gas transportation capacity, it is required to
consider gas pipeline constraints in solving the optimization problem
and evaluate the impacts of gas consumption in power plants on gas
pipelines operating condition. This paper studies about operating of
gas fired power plants in critical conditions when the demand of gas
and electricity peak together. An integrated model of gas and electric
model is used to consider the gas pipeline constraints in the economic
dispatch problem of gas-fueled thermal generator units.
Abstract: Environment-assisted cracking (EAC) is one of the most serious causes of structural failure over a broad range of industrial applications including offshore structures. In EAC condition there is not a definite relation such as Paris equation in Linear Elastic Fracture Mechanics (LEFM). According to studying and searching a lot what the researchers said either a material has contact with hydrogen or any other corrosive environment, phenomenon of electrical and chemical reactions of material with its environment will be happened. In the literature, there are many different works to consider fatigue crack growing and solve it but they are experimental works. Thus, in this paper, authors have an aim to evaluate mathematically the pervious works in LEFM. Obviously, if an environment is more sour and corrosive, the changes of stress intensity factor is more and the calculation of stress intensity factor is difficult. A mathematical relation to deal with the stress intensity factor during the diffusion of sour environment especially hydrogen in a marine pipeline is presented. By using this relation having and some experimental relation an analytical formulation will be presented which enables the fatigue crack growth and critical crack length under cyclic loading to be predicted. In addition, we can calculate KSCC and stress intensity factor in the pipeline caused by EAC.