Abstract: This article discusses the possibility of using dilatometer tests (DMT) together with in situ seismic tests (MASW) in order to get the shape of G-g degradation curve in cohesive soils (clay, silty clay, silt, clayey silt and sandy silt). MASW test provides the small soil stiffness (Go from vs) at very small strains and DMT provides the stiffness of the soil at ‘work strains’ (MDMT). At different test locations, dilatometer shear stiffness of the soil has been determined by the theory of elasticity. Dilatometer shear stiffness has been compared with the theoretical G-g degradation curve in order to determine the typical range of shear deformation for different types of cohesive soil. The analysis also includes factors that influence the shape of the degradation curve (G-g) and dilatometer modulus (MDMT), such as the overconsolidation ratio (OCR), plasticity index (IP) and the vertical effective stress in the soil (svo'). Parametric study in this article defines the range of shear strain gDMT and GDMT/Go relation depending on the classification of a cohesive soil (clay, silty clay, clayey silt, silt and sandy silt), function of density (loose, medium dense and dense) and the stiffness of the soil (soft, medium hard and hard). The article illustrates the potential of using MASW and DMT to obtain G-g degradation curve in cohesive soils.
Abstract: Near-surface loose sediments and local ground conditions in general have a major influence on seismic response of structures. It is a difficult task to model ground behavior in seismic soil-structure-foundation interaction problems, fully account for them in seismic design of structures, or even properly consider them in seismic hazard assessment. In this study, we focused on applying seismic soil investigation methods, used for determining soil stiffness and damping properties, to response analysis used in seismic design. A site in Budapest, Hungary was investigated using Multichannel Analysis of Surface Waves, Seismic Cone Penetration Tests, Bender Elements, Resonant Column and Torsional Shear tests. Our aim was to compare the results of the different test methods and use the resulting soil properties for 1D ground response analysis. Often in practice, there are little-to no data available on dynamic soil properties and estimated parameters are used for design. Therefore, a comparison is made between results based on estimated parameters and those based on detailed investigations. Ground response results are also compared to Eurocode 8 design spectra.
Abstract: The understanding of geotechnical characteristics of
near-surface material and the effects of the groundwater is very
important problem in such as site studies. For showing the relations
between seismic data and groundwater, we selected about 25 km2 as
the study area. It has been presented which is a detailed work of
seismic data and groundwater depths of Gokpinar Damp area.
Seismic waves velocity (Vp and Vs) are very important parameters
showing the soil properties. The seismic records were used the
method of the multichannel analysis of surface waves near area of
Gokpinar Damp area. Sixty sites in this area have been investigated
with survey lines about 60 m in length. MASW (Multichannel
analysis of surface wave) method has been used to generate onedimensional
shear wave velocity profile at locations. These shear
wave velocities are used to estimate equivalent shear wave velocity in
the study area at every 2 and 5 m intervals up to a depth of 45 m.
Levels of equivalent shear wave velocity of soil are used the
classified of the study area. After the results of the study, it must be
considered as components of urban planning and building design of
Gokpinar Damp area, Denizli and the application and use of these
results should be required and enforced by municipal authorities.
Abstract: This study has been presented which is a detailed
work of seismic microzonation of the city center. For seismic
microzonation area of 225 km2 has been selected as the study area.
MASW (Multichannel analysis of surface wave) and seismic
refraction methods have been used to generate one-dimensional shear
wave velocity profile at 250 locations and two-dimensional profile at
60 locations. These shear wave velocities are used to estimate
equivalent shear wave velocity in the study area at every 2 and 5 m
intervals up to a depth of 60 m. Levels of equivalent shear wave
velocity of soil are used the classified of the study area. After the
results of the study, it must be considered as components of urban
planning and building design of Denizli and the application and use
of these results should be required and enforced by municipal
authorities.
Abstract: Multichannel Analysis of Surface Wave (MASW) seismic method is widely used in geotechnical engineering for the measurement of shear wave velocity and evaluation of material property. This method was recently conducted at a Dam site located in Zaria, within the basement complex of northern Nigeria. The aim of this experiment was to make use of the MASW method in evaluating the strength of material properties of a section of the Dam embankment, which is vital to ascertain the safety of the Dam. The result revealed that, the material embankment showed general increase of shear wave velocity with depth. The range of shear wave velocities and the determined Poisson’s ratio falls within the normal range of consolidated rock material, indicating the Dam embankment is still consolidated. The range of shear modulus determined, also shows that the Dam embankment is rigid enough to withstand the shear stress imposed by the impounded water.
Abstract: In this paper, several improvements are proposed to
previous work of automated classification of alcoholics and nonalcoholics.
In the previous paper, multiplayer-perceptron neural
network classifying energy of gamma band Visual Evoked Potential
(VEP) signals gave the best classification performance using 800
VEP signals from 10 alcoholics and 10 non-alcoholics. Here, the
dataset is extended to include 3560 VEP signals from 102 subjects:
62 alcoholics and 40 non-alcoholics. Three modifications are
introduced to improve the classification performance: i) increasing
the gamma band spectral range by increasing the pass-band width of
the used filter ii) the use of Multiple Signal Classification algorithm
to obtain the power of the dominant frequency in gamma band VEP
signals as features and iii) the use of the simple but effective knearest
neighbour classifier. To validate that these two modifications
do give improved performance, a 10-fold cross validation
classification (CVC) scheme is used. Repeat experiments of the
previously used methodology for the extended dataset are performed
here and improvement from 94.49% to 98.71% in maximum
averaged CVC accuracy is obtained using the modifications. This
latest results show that VEP based classification of alcoholics is
worth exploring further for system development.
Abstract: In this paper, a second order autoregressive (AR)
model is proposed to discriminate alcoholics using single trial
gamma band Visual Evoked Potential (VEP) signals using 3 different
classifiers: Simplified Fuzzy ARTMAP (SFA) neural network (NN),
Multilayer-perceptron-backpropagation (MLP-BP) NN and Linear
Discriminant (LD). Electroencephalogram (EEG) signals were
recorded from alcoholic and control subjects during the presentation
of visuals from Snodgrass and Vanderwart picture set. Single trial
VEP signals were extracted from EEG signals using Elliptic filtering
in the gamma band spectral range. A second order AR model was
used as gamma band VEP exhibits pseudo-periodic behaviour and
second order AR is optimal to represent this behaviour. This
circumvents the requirement of having to use some criteria to choose
the correct order. The averaged discrimination errors of 2.6%, 2.8%
and 11.9% were given by LD, MLP-BP and SFA classifiers. The
high LD discrimination results show the validity of the proposed
method to discriminate between alcoholic subjects.
Abstract: Classification of electroencephalogram (EEG) signals
extracted during mental tasks is a technique that is actively pursued
for Brain Computer Interfaces (BCI) designs. In this paper, we
compared the classification performances of univariateautoregressive
(AR) and multivariate autoregressive (MAR) models
for representing EEG signals that were extracted during different
mental tasks. Multilayer Perceptron (MLP) neural network (NN)
trained by the backpropagation (BP) algorithm was used to classify
these features into the different categories representing the mental
tasks. Classification performances were also compared across
different mental task combinations and 2 sets of hidden units (HU): 2
to 10 HU in steps of 2 and 20 to 100 HU in steps of 20. Five different
mental tasks from 4 subjects were used in the experimental study and
combinations of 2 different mental tasks were studied for each
subject. Three different feature extraction methods with 6th order
were used to extract features from these EEG signals: AR
coefficients computed with Burg-s algorithm (ARBG), AR
coefficients computed with stepwise least square algorithm (ARLS)
and MAR coefficients computed with stepwise least square
algorithm. The best results were obtained with 20 to 100 HU using
ARBG. It is concluded that i) it is important to choose the suitable
mental tasks for different individuals for a successful BCI design, ii)
higher HU are more suitable and iii) ARBG is the most suitable
feature extraction method.
Abstract: This paper reports a new approach on identifying the
individuality of persons by using parametric classification of multiple
mental thoughts. In the approach, electroencephalogram (EEG)
signals were recorded when the subjects were thinking of one or
more (up to five) mental thoughts. Autoregressive features were
computed from these EEG signals and classified by Linear
Discriminant classifier. The results here indicate that near perfect
identification of 400 test EEG patterns from four subjects was
possible, thereby opening up a new avenue in biometrics.
Abstract: In this present work, the development of an avionics
system for flight data collection of a Raptor 30 V2 is carried out. For the data acquisition both onground and onboard avionics systems are developed for testing of a small-scale Unmanned Aerial Vehicle
(UAV) helicopter. The onboard avionics record the helicopter state
outputs namely accelerations, angular rates and Euler angles, in real time, and the on ground avionics system record the inputs given to
the radio controlled helicopter through a transmitter, in real time. The avionic systems are designed and developed taking into consideration
low weight, small size, anti-vibration, low power consumption, and easy interfacing. To mitigate the medium frequency vibrations
embedded on the UAV helicopter during flight, a damper is designed
and its performance is evaluated. A number of flight tests are carried
out and the data obtained is then analyzed for accuracy and repeatability and conclusions are inferred.
Abstract: This paper demonstrates the results when either
Shiftrows stage or Mixcolumns stage and when both the stages are
omitted in the well known block cipher Advanced Encryption
Standard(AES) and its modified version AES with Key Dependent
S-box(AES-KDS), using avalanche criterion and other tests namely
encryption quality, correlation coefficient, histogram analysis and
key sensitivity tests.
Abstract: In single trial analysis, when using Principal
Component Analysis (PCA) to extract Visual Evoked Potential
(VEP) signals, the selection of principal components (PCs) is an
important issue. We propose a new method here that selects only
the appropriate PCs. We denote the method as selective eigen-rate
(SER). In the method, the VEP is reconstructed based on the rate
of the eigen-values of the PCs. When this technique is applied on
emulated VEP signals added with background
electroencephalogram (EEG), with a focus on extracting the
evoked P3 parameter, it is found to be feasible. The improvement
in signal to noise ratio (SNR) is superior to two other existing
methods of PC selection: Kaiser (KSR) and Residual Power (RP).
Though another PC selection method, Spectral Power Ratio (SPR)
gives a comparable SNR with high noise factors (i.e. EEGs), SER
give more impressive results in such cases. Next, we applied SER
method to real VEP signals to analyse the P3 responses for
matched and non-matched stimuli. The P3 parameters extracted
through our proposed SER method showed higher P3 response for
matched stimulus, which confirms to the existing neuroscience
knowledge. Single trial PCA using KSR and RP methods failed to
indicate any difference for the stimuli.