Abstract: The increasing penetration of Distributed Generation and storage connected to the distribution network via PWM converters increases the possibility of a DC-component (offset) in voltage or current flowing into the grid. This occurs when even harmonics are present in the network voltage. DC-components can affect the operation and safety of several grid components. Therefore, an investigation of the way they are produced is important in order to take appropriate measures for their elimination. Further research on DC-components that appear on output voltage of converters is performed for different parameters of PWM technique and characteristics of even harmonics.
Abstract: Multilevel inverters such as flying capacitor, diodeclamped,
and cascaded H-bridge inverters are very popular
particularly in medium and high power applications. This paper
focuses on a cascaded H-bridge module using a single direct current
(DC) source in order to generate an 11-level output voltage. The
noble approach reduces the number of switches and gate drivers, in
comparison with a conventional method. The anticipated topology
produces more accurate result with an isolation transformer at high
switching frequency. Different modulation techniques can be used for
the multilevel inverter, but this work features modulation techniques
known as selective harmonic elimination (SHE).This modulation
approach reduces the number of carriers with reduction in Switching
Losses, Total Harmonic Distortion (THD), and thereby increasing
Power Quality (PQ). Based on the simulation result obtained, it
appears SHE has the ability to eliminate selected harmonics by
chopping off the fundamental output component. The performance
evaluation of the proposed cascaded multilevel inverter is performed
using PSIM simulation package and THD of 0.94% is obtained.
Abstract: Multilevel inverter is a promising inverter topology for high voltage and high power applications. This inverter synthesizes several different levels of DC voltages to produce a stepped AC output that approaches the pure sine waveform. The three different topologies, diode-clamped inverter, capacitor-clamped inverter and cascaded h-bridge multilevel inverter are widely used in these multilevel inverters. Among the three topologies, cascaded h-bridge multilevel inverter is more suitable for photovoltaic applications since each PV array can act as a separate dc source for each h-bridge module. This research especially focus on photovoltaic power source as input to the system and shows the potential of a Single Phase Cascaded H-bridge Eleven level inverter governed by the fuzzy logic controller to improve the power quality by reducing the total harmonic distortion at the output voltage. Hence the efficiency of the system will be improved. Simulation using MATLAB/SIMULINK has been done to verify the performance of cascaded h-bridge eleven level inverter using sinusoidal pulse width modulation technique. The simulated output shows very favorable result.
Abstract: This paper presents advances in pulse width modulation techniques which refers to a method of carrying information on train of pulses and the information be encoded in the width of pulses. Pulse Width Modulation is used to control the inverter output voltage. This is done by exercising the control within the inverter itself by adjusting the ON and OFF periods of inverter. By fixing the DC input voltage we get AC output voltage. In variable speed AC motors the AC output voltage from a constant DC voltage is obtained by using inverter. Recent developments in power electronics and semiconductor technology have lead improvements in power electronic systems. Hence, different circuit configurations namely multilevel inverters have became popular and considerable interest by researcher are given on them. A fast space-vector pulse width modulation (SVPWM) method for five-level inverter is also discussed. In this method, the space vector diagram of the five-level inverter is decomposed into six space vector diagrams of three-level inverters. In turn, each of these six space vector diagrams of three-level inverter is decomposed into six space vector diagrams of two-level inverters. After decomposition, all the remaining necessary procedures for the three-level SVPWM are done like conventional two-level inverter. The proposed method reduces the algorithm complexity and the execution time. It can be applied to the multilevel inverters above the five-level also. The experimental setup for three-level diode-clamped inverter is developed using TMS320LF2407 DSP controller and the experimental results are analyzed.
Abstract: This paper presents a comparison between Proportional Integral (PI) and Proportional Resonant (PR) current controllers used in Grid Connected Photovoltaic (PV) Inverters. Both simulation and experimental results will be presented. A 3kW Grid-Connected PV Inverter was designed and constructed for this research.
Abstract: Renewable Energy based microgrids are being considered to provide electricity for the expanding energy demand in the grid distribution network and grid isolated areas. The technical challenges associated with the operation and controls are immense. Electricity generation by Renewable Energy Sources is of stochastic nature such that there is a demand for regulation of voltage output in order to satisfy the standard loads’ requirements. In a renewable energy based microgrid, the energy sources give stochastically variable magnitude AC or DC voltages. AC voltage regulation of micro and mini sources pose practical challenges as well as unbearable costs. It is therefore practically and economically viable to convert the voltage outputs from stochastic AC and DC voltage sources to constant DC voltage to satisfy various DC loads including inverters which ultimately feed AC loads. This paper presents results obtained from SEPIC converter based DC bus voltage regulator as a case study for renewable energy microgrid application. Real-Time Simulation results show that upon appropriate choice of controller parameters for control of the SEPIC converter, the output DC bus voltage can be kept constant regardless of wide range of voltage variations of the source. This feature is particularly important in the situation that multiple renewable sources are to be integrated to supply a microgrid under main grid integration or isolated modes of operation.
Abstract: The development of the power electronics has allowed
increasing the precision and reliability of the electrical trainings,
thanks to the adjustable inverters, as the Pulse Wide Modulation
(PWM) five level inverters, which is the object of study in this
article.The authors treat the relation between the law order adopted for
a given system and the oscillations of the electrical and mechanical
parameters of which the tolerance depends on the process with which
they are integrated (paper factory, lifting of the heavy loads,
etc.).Thus the best choice of the regulation indexes allows us to
achieve stability and safety training without investment (management
of existing equipment).
Abstract: Back-to-back static synchronous compensator (BtBSTATCOM) consists of two back-to-back voltage-source converters (VSC) with a common DC link in a substation. This configuration extends the capabilities of conventional STATCOM that bidirectional active power transfer from one bus to another is possible. In this paper, VSCs are designed in quasi multi-pulse form in which GTOs are triggered only once per cycle in PSCAD/EMTDC. The design details of VSCs as well as gate switching circuits and controllers are fully represented. Regulation modes of BtBSTATCOM are verified and tested on a multi-machine power system through different simulation cases. The results presented in the form of typical time responses show that practical PI controllers are almost robust and stable in case of start-up, set-point change, and line faults.
Abstract: A new topology of unified power quality conditioner
(UPQC) is proposed for different power quality (PQ) improvement in
a three-phase four-wire (3P-4W) distribution system. For neutral
current mitigation, a star-hexagon transformer is connected in shunt
near the load along with three-leg voltage source inverters (VSIs)
based UPQC. For the mitigation of source neutral current, the uses of
passive elements are advantageous over the active compensation due
to ruggedness and less complexity of control. In addition to this, by
connecting a star-hexagon transformer for neutral current mitigation
the over all rating of the UPQC is reduced. The performance of the
proposed topology of 3P-4W UPQC is evaluated for power-factor
correction, load balancing, neutral current mitigation and mitigation
of voltage and currents harmonics. A simple control algorithm based
on Unit Vector Template (UVT) technique is used as a control
strategy of UPQC for mitigation of different PQ problems. In this
control scheme, the current/voltage control is applied over the
fundamental supply currents/voltages instead of fast changing APFs
currents/voltages, thereby reducing the computational delay.
Moreover, no extra control is required for neutral source current
compensation; hence the numbers of current sensors are reduced. The
performance of the proposed topology of UPQC is analyzed through
simulations results using MATLAB software with its Simulink and
Power System Block set toolboxes.
Abstract: This paper presents two different sequential switching hybrid-modulation strategies and implemented for cascaded multilevel inverters. Hybrid modulation strategies represent the combinations of Fundamental-frequency pulse width modulation (FFPWM) and Multilevel sinusoidal-modulation (MSPWM) strategies, and are designed for performance of the well-known Alternative Phase opposition disposition (APOD), Phase shifted carrier (PSC). The main characteristics of these modulations are the reduction of switching losses with good harmonic performance, balanced power loss dissipation among the devices with in a cell, and among the series-connected cells. The feasibility of these modulations is verified through spectral analysis, power loss analysis and simulation.
Abstract: Three-phase induction machines are today a standard
for industrial electrical drives. Cost, reliability, robustness and maintenance free operation are among the reasons these machines are
replacing dc drive systems. The development of power electronics
and signal processing systems has eliminated one of the greatest
disadvantages of such ac systems, which is the issue of control. With
modern techniques of field oriented vector control, the task of
variable speed control of induction machines is no longer a
disadvantage. The need to increase system performance, particularly
when facing limits on the power ratings of power supplies and
semiconductors, motivates the use of phase number other than three,
In this paper a novel scheme of connecting two, three phase
induction motors in parallel fed by two inverters; viz. VSI and CSI
and their vector control is presented.
Abstract: With the rapid advanced of technology, the industrial processes become increasingly demanding, from the point of view, power quality and controllability. The advent of multi levels inverters responds partially to these requirements. But actually, the new generation of multi-cells inverters permits to reach more performances, since, it offers more voltage levels. The disadvantage in the increase of voltage levels by the number of cells in cascades is on account of series igbts synchronisation loss, from where, a limitation of cells in cascade to 4. Regarding to these constraints, a new topology is proposed in this paper, which increases the voltage levels of the three-cell inverter from 4 to 8; with the same number of igbts, and using less stored energy in the flaying capacitors. The details of operation and modelling of this new inverter structure are also presented, then tested thanks to a three phase induction motor. KeywordsFlaying capacitors, Multi-cells inverter, pwm, switchers, modelling.
Abstract: The development of the power electronics has allowed
increasing the precision and reliability of the electrical devices, thanks
to the adjustable inverters, as the Pulse Wide Modulation (PWM)
applied to the three level inverters, which is the object of this study.
The authors treat the relation between the law order adopted for a
given system and the oscillations of the electrical and mechanical
parameters of which the tolerance depends on the process with which
they are integrated (paper factory, lifting of the heavy loads,
etc.).Thus, the best choice of the regulation indexes allows us to
achieve stability and safety training without investment (management
of existing equipment). The optimal behavior of any electric device
can be achieved by the minimization of the stored electrical and
mechanical energy.
Abstract: This paper present the harmonic elimination of hybrid
multilevel inverters (HMI) which could be increase the number of
output voltage level. Total Harmonic Distortion (THD) is one of the
most important requirements concerning performance indices.
Because of many numbers output levels of HMI, it had numerous
unknown variables of eliminate undesired individual harmonic and
THD nonlinear equations set. Optimized harmonic stepped waveform
(OHSW) is solving switching angles conventional method, but most
complicated for solving as added level. The artificial intelligent
techniques are deliberation to solve this problem. This paper presents
the Particle Swarm Optimization (PSO) technique for solving
switching angles to get minimum THD and eliminate undesired
individual harmonics of 15-levels hybrid multilevel inverters.
Consequently it had many variables and could eliminate numerous
harmonics. Both advantages including high level of inverter and
Particle Swarm Optimization (PSO) are used as powerful tools for
harmonics elimination.
Abstract: Multi-level voltage source inverters offer several
advantages such as; derivation of a refined output voltage with
reduced total harmonic distortion (THD), reduction of voltage ratings
of the power semiconductor switching devices and also the reduced
electro-magnetic-interference problems etc. In this paper, new
carrier-overlapped phase-disposition or sub-harmonic sinusoidal
pulse width modulation (CO-PD-SPWM) and also the carrieroverlapped
phase-disposition space vector modulation (CO-PDSVPWM)
schemes for a six-level diode-clamped inverter topology
are proposed. The principle of the proposed PWM schemes is similar
to the conventional PD-PWM with a little deviation from it in the
sense that the triangular carriers are all overlapped. The overlapping
of the triangular carriers on one hand results in an increased number
of switchings, on the other hand this facilitates an improved spectral
performance of the output voltage. It is demonstrated through
simulation studies that the six-level diode-clamped inverter with the
use of CO-PD-SPWM and CO-PD-SVPWM proposed in this paper is
capable of generating multiple levels in its output voltage. The
advantages of the proposed PWM schemes can be derived to benefit,
especially at lower modulation indices of the inverter and hence this
aspect of the proposed PWM schemes can be well exploited in high
power applications requiring low speeds of operation of the drive.
Abstract: This paper presents the design and analysis of a parallel
connected inverter configuration of. The configuration consists of
parallel connected three-phase dc/ac inverter. Series resistors added
to the inverter output to maintain same current in each inverter of the
two parallel inverters, and to reduce the circulating current in the
parallel inverters to the minimum. High frequency third harmonic
injection PWM (THIPWM) employed to reduce the total harmonic
distortion and to make maximum use of the voltage source. DSP was
used to generate the THIPWM and the control algorithm for the
converter. Selected experimental results have been shown to validate
the proposed system.
Abstract: In this paper, an ultra low power and low jitter 12bit
CMOS digitally controlled oscillator (DCO) design is presented.
Based on a ring oscillator implemented with low power Schmitt
trigger based inverters. Simulation of the proposed DCO using 32nm
CMOS Predictive Transistor Model (PTM) achieves controllable
frequency range of 550MHz~830MHz with a wide linearity and high
resolution. Monte Carlo simulation demonstrates that the time-period
jitter due to random power supply fluctuation is under 31ps and the
power consumption is 0.5677mW at 750MHz with 1.2V power
supply and 0.53-ps resolution. The proposed DCO has a good
robustness to voltage and temperature variations and better linearity
comparing to the conventional design.
Abstract: Rapid progress in process automation and tightening
quality standards result in a growing demand being placed on fault
detection and diagnostics methods to provide both speed and
reliability of motor quality testing. Doubly fed induction generators
are used mainly for wind energy conversion in MW power plants.
This paper presents a detection of an inter turn stator and an open
phase faults, in a doubly fed induction machine whose stator and
rotor are supplied by two pulse width modulation (PWM) inverters.
The method used in this article to detect these faults, is based on
Park-s Vector Approach, using a neural network.
Abstract: Nowadays Multilevel inverters are widely using in various applications. Modulation strategy at fundamental switching frequency like, SHEPWM is prominent technique to eliminate lower order of harmonics with less switching losses and better harmonic profile. The equations which are formed by SHE are highly nonlinear transcendental in nature, there may exist single, multiple or even no solutions for a particular MI. However, some loads such as electrical drives, it is required to operate in whole range of MI. In order to solve SHE equations for whole range of MI, intelligent techniques are well suited to solve equations so as to produce lest %THDV. Hence, this paper uses Continuous genetic algorithm for minimising harmonics. This paper also presents wavelet based analysis of harmonics. The developed algorithm is simulated and %THD from FFT analysis and Wavelet analysis are compared. MATLAB programming environment and SIMULINK models are used whenever necessary.
Abstract: Multilevel inverters supplied from equal and constant
dc sources almost don-t exist in practical applications. The variation
of the dc sources affects the values of the switching angles required
for each specific harmonic profile, as well as increases the difficulty
of the harmonic elimination-s equations. This paper presents an
extremely fast optimal solution of harmonic elimination of multilevel
inverters with non-equal dc sources using Tanaka's fuzzy linear
regression formulation. A set of mathematical equations describing
the general output waveform of the multilevel inverter with nonequal
dc sources is formulated. Fuzzy linear regression is then
employed to compute the optimal solution set of switching angles.