Abstract: In this work, the laser ultrasound technique has been used for analyzing and imaging the inner defects in metal blocks. To detect the defects in blocks, traditionally the researchers used piezoelectric transducers for the generation and reception of ultrasonic signals. These transducers can be configured into the sparse and phased array. But these two configurations have their drawbacks including the requirement of many transducers, time-consuming calculations, limited bandwidth, and provide confined image resolution. Here, we focus on the non-contact method for generating and receiving the ultrasound to examine the inner defects in aluminum blocks. A Q-switched pulsed laser has been used for the generation and the reception is done by using Laser Doppler Vibrometer (LDV). Based on the Doppler effect, LDV provides a rapid and high spatial resolution way for sensing ultrasonic waves. From the LDV, a series of scanning points are selected which serves as the phased array elements. The side-drilled hole of 10 mm diameter with a depth of 25 mm has been introduced and the defect is interrogated by the linear array of scanning points obtained from the LDV. With the aid of the Synthetic Aperture Focusing Technique (SAFT) algorithm, based on the time-shifting principle the inspected images are generated from the A-scan data acquired from the 1-D linear phased array elements. Thus the defect can be precisely detected with good resolution.
Abstract: The paper presents the study of synthetic transmit
aperture method applying the Golay coded transmission for medical
ultrasound imaging. Longer coded excitation allows to increase the
total energy of the transmitted signal without increasing the peak
pressure. Signal-to-noise ratio and penetration depth are improved
maintaining high ultrasound image resolution.
In the work the 128-element linear transducer array with 0.3 mm
inter-element spacing excited by one cycle and the 8 and 16-bit
Golay coded sequences at nominal frequencies 4 MHz was used.
Single element transmission aperture was used to generate a spherical
wave covering the full image region and all the elements received the
echo signals. The comparison of 2D ultrasound images of the wire
phantom as well as of the tissue mimicking phantom is presented to
demonstrate the benefits of the coded transmission. The results were
obtained using the synthetic aperture algorithm with transmit and
receive signals correction based on a single element directivity
function.
Abstract: Synthetic Aperture Radar (SAR) is an imaging radar form by taking full advantage of the relative movement of the antenna with respect to the target. Through the simultaneous processing of the radar reflections over the movement of the antenna via the Range Doppler Algorithm (RDA), the superior resolution of a theoretical wider antenna, termed synthetic aperture, is obtained. Therefore, SAR can achieve high resolution two dimensional imagery of the ground surface. In addition, two filtering steps in range and azimuth direction provide accurate enough result. This paper develops a simulation in which realistic SAR images can be generated. Also, the effect of velocity errors in the resulting image has also been investigated. Taking some velocity errors into account, the simulation results on the image resolution would be presented. Most of the times, algorithms need to be adjusted for particular datasets, or particular applications.