Abstract: A new digital watermarking technique for images that
are sensitive to blocking artifacts is presented. Experimental results
show that the proposed MDCT based approach produces highly
imperceptible watermarked images and is robust to attacks such as
compression, noise, filtering and geometric transformations. The
proposed MDCT watermarking technique is applied to fingerprints
for ensuring security. The face image and demographic text data of
an individual are used as multiple watermarks. An AFIS system was
used to quantitatively evaluate the matching performance of the
MDCT-based watermarked fingerprint. The high fingerprint
matching scores show that the MDCT approach is resilient to
blocking artifacts. The quality of the extracted face and extracted text
images was computed using two human visual system metrics and
the results show that the image quality was high.
Abstract: Automatic tube current modulation (ATCM) systems are available for all CT manufacturers and are used for the majority of patients. Understanding how the systems work and their influence on patient dose and image quality is important for CT users, in order to gain the most effective use of the systems. In the present study, a new phantom was used for evaluating dose distribution and image quality under the ATCM operation for the Toshiba Aquilion 64 CT scanner using different ATCM options and a fixed mAs technique. A routine chest, abdomen and pelvis (CAP) protocol was selected for study and Gafchromic film was used to measure entrance surface dose (ESD), peripheral dose and central axis dose in the phantom. The results show the dose reductions achievable with various ATCM options, in relation with the target noise. The doses and image noise distribution were more uniform when the ATCM system was implemented compared with the fixed mAs technique. The lower limit set for the tube current will affect the modulations especially for the lower dose option. This limit prevented the tube current being reduced further and therefore the lower dose ATCM setting resembled a fixed mAs technique. Selection of a lower tube current limit is likely to reduce doses for smaller patients in scans of chest and neck regions.
Abstract: Psoriasis is a widespread skin disease affecting up to 2% population with plaque psoriasis accounting to about 80%. It can be identified as a red lesion and for the higher severity the lesion is usually covered with rough scale. Psoriasis Area Severity Index (PASI) scoring is the gold standard method for measuring psoriasis severity. Scaliness is one of PASI parameter that needs to be quantified in PASI scoring. Surface roughness of lesion can be used as a scaliness feature, since existing scale on lesion surface makes the lesion rougher. The dermatologist usually assesses the severity through their tactile sense, therefore direct contact between doctor and patient is required. The problem is the doctor may not assess the lesion objectively. In this paper, a digital image analysis technique is developed to objectively determine the scaliness of the psoriasis lesion and provide the PASI scaliness score. Psoriasis lesion is modelled by a rough surface. The rough surface is created by superimposing a smooth average (curve) surface with a triangular waveform. For roughness determination, a polynomial surface fitting is used to estimate average surface followed by a subtraction between rough and average surface to give elevation surface (surface deviations). Roughness index is calculated by using average roughness equation to the height map matrix. The roughness algorithm has been tested to 444 lesion models. From roughness validation result, only 6 models can not be accepted (percentage error is greater than 10%). These errors occur due the scanned image quality. Roughness algorithm is validated for roughness measurement on abrasive papers at flat surface. The Pearson-s correlation coefficient of grade value (G) of abrasive paper and Ra is -0.9488, its shows there is a strong relation between G and Ra. The algorithm needs to be improved by surface filtering, especially to overcome a problem with noisy data.
Abstract: The need of high frame-rate imaging has been triggered by the new applications of ultrasound imaging to transient elastography and real-time 3D ultrasound. Using plane wave excitation (PWE) is one of the methods to achieve very high frame-rate imaging since an image can be formed with a single insonification. However, due to the lack of transmit focusing, the image quality with PWE is lower compared with those using conventional focused transmission. To solve this problem, we propose a filter-retrieved transmit focusing (FRF) technique combined with cross-correlation weighting (FRF+CC weighting) for high frame-rate imaging with PWE. A restrospective focusing filter is designed to simultaneously minimize the predefined sidelobe energy associated with single PWE and the filter energy related to the signal-to-noise-ratio (SNR). This filter attempts to maintain the mainlobe signals and to reduce the sidelobe ones, which gives similar mainlobe signals and different sidelobes between the original PWE and the FRF baseband data. Normalized cross-correlation coefficient at zero lag is calculated to quantify the degree of similarity at each imaging point and used as a weighting matrix to the FRF baseband data to further suppress sidelobes, thus improving the filter-retrieved focusing quality.
Abstract: In this paper, we present a novel objective nonreference
performance assessment algorithm for image fusion. It takes
into account local measurements to estimate how well the important
information in the source images is represented by the fused image.
The metric is based on the Universal Image Quality Index and uses
the similarity between blocks of pixels in the input images and the
fused image as the weighting factors for the metrics. Experimental
results confirm that the values of the proposed metrics correlate well
with the subjective quality of the fused images, giving a significant
improvement over standard measures based on mean squared error
and mutual information.
Abstract: This frame work describes a computationally more
efficient and adaptive threshold estimation method for image
denoising in the wavelet domain based on Generalized Gaussian
Distribution (GGD) modeling of subband coefficients. In this
proposed method, the choice of the threshold estimation is carried out
by analysing the statistical parameters of the wavelet subband
coefficients like standard deviation, arithmetic mean and geometrical
mean. The noisy image is first decomposed into many levels to
obtain different frequency bands. Then soft thresholding method is
used to remove the noisy coefficients, by fixing the optimum
thresholding value by the proposed method. Experimental results on
several test images by using this method show that this method yields
significantly superior image quality and better Peak Signal to Noise
Ratio (PSNR). Here, to prove the efficiency of this method in image
denoising, we have compared this with various denoising methods
like wiener filter, Average filter, VisuShrink and BayesShrink.
Abstract: Glaucoma diagnosis involves extracting three features
of the fundus image; optic cup, optic disc and vernacular. Present
manual diagnosis is expensive, tedious and time consuming. A
number of researches have been conducted to automate this process.
However, the variability between the diagnostic capability of an
automated system and ophthalmologist has yet to be established. This
paper discusses the efficiency and variability between
ophthalmologist opinion and digital technique; threshold. The
efficiency and variability measures are based on image quality
grading; poor, satisfactory or good. The images are separated into
four channels; gray, red, green and blue. A scientific investigation
was conducted on three ophthalmologists who graded the images
based on the image quality. The images are threshold using multithresholding
and graded as done by the ophthalmologist. A
comparison of grade from the ophthalmologist and threshold is made.
The results show there is a small variability between result of
ophthalmologists and digital threshold.