Abstract: The present study is carried out to investigate the magneto-viscous effects on incompressible ferrofluid flow over a porous rotating disc with suction or injection on the surface of the disc subjected to a magnetic field. The flow under consideration is axi-symmetric steady ferrofluid flow of electrically non-conducting fluid. Karman’s transformation is used to convert the governing boundary layer equations involved in the problem to a system of non linear coupled differential equations. The solution of this system is obtained by using power series approximation. The flow characteristics i.e. radial, tangential, axial velocities and boundary layer displacement thickness are calculated for various values of MFD (magnetic field dependent) viscosity and for different values of suction injection parameter. Besides this, skin friction coefficients are also calculated on the surface of the disk. The results thus obtained are presented numerically and graphically in the paper.
Abstract: An attempt has been made to study the effect of rotation on incompressible, electrically non-conducting ferrofluid in porous medium on Axi-symmetric steady flow over a rotating disk excluding thermal effects. Here, we solved the boundary layer equations with boundary conditions using Neuringer-Rosensweig model considering the z-axis as the axis of rotation. The non linear boundary layer equations involved in the problem are transformed to the non linear coupled ordinary differential equations by Karman's transformation and solved by power series approximations. Besides numerically calculating the velocity components and pressure for different values of porosity parameter with the variation of Karman's parameter we have also calculated the displacement thickness of boundary layer, the total volume flowing outward the z-axis and angle between wall and ferrofluid. The results for all above variables are obtained numerically and discussed graphically.
Abstract: At present, the tendency to implement the conditionbased
maintenance (CBM), which allows the optimization of the
expenses for equipment monitoring, is more and more evident; also,
the transformer substations with remote monitoring are increasingly
used. This paper reviews all the advantages of the on-line monitoring
and presents an equipment for on-line monitoring of bushings, which
is the own contribution of specialists who are the authors of this
paper. The paper presents a study of the temperature field, using the
finite element method. For carrying out this study, the 3D modelling
of the above mentioned bushing was performed. The analysis study is
done taking into account the extreme thermal stresses, focusing at the
level of the first cooling wing section of the ceramic insulator. This
fact enables to justify the tanδ variation in time, depending on the
transformer loading and the environmental conditions. With a view
to reducing the variation of dielectric losses in bushing insulation, the
use of ferrofuids instead of mineral oils is proposed.
Abstract: A biocompatible ferrofluid have been prepared by coprecipitation
of FeCl2.4H2O and FeCl3.6H2O under ultrasonic
irradiation and with NaOH as alkaline agent. Cystein was also used
as capping agent in the solution. Magnetic properties of the produced
ferrofluid were then determined by VSM test and magnetite
nanoparticles were characterized by XRD and TEM techniques. The
effect of surfactant to Fe ion weight ratio was also studied during this
project by using two different amount of Dextran. Results showed the
presence of a biocompatible superparamagnetic ferrofluid including
magnetite nanoparticles with particle size ranging under 20 nm. The
increase in the surfactant content results in the narrowing of the size
distribution and reduction of the particle size and more solution
stability.