Abstract: Non-linear dynamic time history analysis is
considered as the most advanced and comprehensive analytical
method for evaluating the seismic response and performance of
multi-degree-of-freedom building structures under the influence of
earthquake ground motions. However, effective and accurate
application of the method requires the implementation of advanced
hysteretic constitutive models of the various structural components
including masonry infill panels. Sophisticated computational research
tools that incorporate realistic hysteresis models for non-linear
dynamic time-history analysis are not popular among the professional
engineers as they are not only difficult to access but also complex and
time-consuming to use. In addition, commercial computer programs
for structural analysis and design that are acceptable to practicing
engineers do not generally integrate advanced hysteretic models
which can accurately simulate the hysteresis behavior of structural
elements with a realistic representation of strength degradation,
stiffness deterioration, energy dissipation and ‘pinching’ under cyclic
load reversals in the inelastic range of behavior. In this scenario,
push-over or non-linear static analysis methods have gained
significant popularity, as they can be employed to assess the seismic
performance of building structures while avoiding the complexities
and difficulties associated with non-linear dynamic time-history
analysis. “Push-over” or non-linear static analysis offers a practical
and efficient alternative to non-linear dynamic time-history analysis
for rationally evaluating the seismic demands. The present paper is
based on the analytical investigation of the effect of distribution of
masonry infill panels over the elevation of planar masonry infilled
reinforced concrete [R/C] frames on the seismic demands using the
capacity spectrum procedures implementing nonlinear static analysis
[pushover analysis] in conjunction with the response spectrum
concept. An important objective of the present study is to numerically
evaluate the adequacy of the capacity spectrum method using
pushover analysis for performance based design of masonry infilled
R/C frames for near-field earthquake ground motions.
Abstract: The paper aims at investigating the effect of number
of story on different structural components of reinforced concrete
building due to gravity and lateral loading. For the study, three
building models having same building plan of three, six and nine
stories are analyzed and designed using software package. All the
buildings are residential and are located in Dhaka city of Bangladesh.
Lateral load including wind and earthquake loading are applied to the
building along both longitudinal and transverse direction as per
Bangladesh National Building Code (BNBC, 2006). Equivalent static
force method is followed for the applied seismic loading. The present
study investigates as well as compares mainly total steel requirement
in different structural components for those buildings. It has been
found that total longitudinal steel requirement for beams at each floor
is 48.57% for three storied building, 61.36% for six storied building
when the total percentage is taken as 100% in case of nine storied
building. For an exterior column, the steel ratio is 2.1%, 3.06%,
4.55% for three, six and nine storied building respectively for the first
three floors. In addition, it has been noted that total weight of
longitudinal reinforcement of an interior column is 14.02 % for threestoried
building and 43.12% for six storied building when the total
reinforcement is considered 100% for nine storied building for the
first three floors.
Abstract: Environmental and functional conditions, sometimes,
necessitate the architectural plan of the building to be asymmetric,
and this result in an asymmetric structure. In such cases finding an
optimal pattern for locating the components of lateral load bearing
system, including shear walls, in the building’s plan is desired. In
case of shear wall in addition to the location the shape of the wall
cross-section is also an effective factor. Various types of shear walls
and their proper layout might come effective in better stiffness
distribution and more appropriate seismic response of the building.
Several studies have been conducted in the context of analysis and
design of shear walls; however, few studies have been performed on
making decisions for the location and form of shear walls in multistory
buildings, especially those with irregular plan. In this study, an
attempt has been made to obtain the most reliable seismic behavior of
multi-story reinforced concrete vertically chamfered buildings by
using more appropriate shear walls form and arrangement in 7-, 10-,
12-, and 15-stoy buildings. The considered forms and arrangements
include common rectangular walls and L-, T-, U- and Z-shaped plan,
located as the core or in the outer frames of the building structure.
Comparison of seismic behaviors of the buildings, including
maximum roof displacement and particularly formation of plastic
hinges and their distribution in the buildings’ structures, have been
done based on the results of a series of nonlinear time history
analyses, by using a set of selected earthquake records. Results show
that shear walls with U-shaped cross-section, placed as the building
central core, and also walls with Z-shaped cross-section, placed at the
corners give the building more reliable seismic behavior.
Abstract: Analyzing the relation networks between the hospital
buildings which have complex structure and distinctive spatial
relationships is quite difficult. The hospital buildings which require
specialty in spatial relationship solutions during design and selfinnovation
through the developing technology should survive and
keep giving service even after the disasters such as earthquakes. In
this study, a hospital building where the load-bearing system was
strengthened because of the insufficient earthquake performance and
the construction of an additional building was required to meet the
increasing need for space was discussed and a comparative spatial
evaluation of the hospital building was made with regard to its status
before the change and after the change. For this reason, spatial
organizations of the building before change and after the change were
analyzed by means of Space Syntax method and the effects of the
change on space organization parameters were searched by applying
an analytical procedure. Using Depthmap UCL software,
Connectivity, Visual Mean Depth, Beta and Visual Integration
analyses were conducted. Based on the data obtained after the
analyses, it was seen that the relationships between spaces of the
building increased after the change and the building has become more
explicit and understandable for the occupants. Furthermore, it was
determined according to findings of the analysis that the increase in
depth causes difficulty in perceiving the spaces and the changes
considering this problem generally ease spatial use.
Abstract: The seriously damaged structures during earthquakes
show the need and importance of design of reinforced concrete
structures with high ductility. Reinforced concrete beam-column
joints have an important function in all structures. Under seismic
excitation, the beam column joint region is subjected to horizontal
and vertical shear forces whose magnitude is many times higher than
the adjacent beam and column. Strength and ductility of structures
depends mainly on proper detailing of the reinforcement in beamcolumn
joints and the old structures were found ductility deficient.
DSP materials are obtained by using high quantities of super
plasticizers and high volumes of micro silica. In the case of High
Performance Densified Small Particle Concrete (HPDSPC), since
concrete is dense even at the micro-structure level, tensile strain
would be much higher than that of the conventional SFRC, SIFCON
& SIMCON. This in turn will improve cracking behaviour, ductility
and energy absorption capacity of composites in addition to
durability. The fine fibers used in our mix are 0.3mm diameter and 10
mm which can be easily placed with high percentage. These fibers
easily transfer stresses and act as a composite concrete unit to take up
extremely high loads with high compressive strength. HPDSPC
placed in the beam column joints helps in safety of human life due to
prolonged failure.
Abstract: Nowadays, energy dissipation devices are commonly
used in structures. High rate of energy absorption during earthquakes
is the benefit of using such devices, which results in damage
reduction of structural elements, specifically columns. The hysteretic
damping capacity of energy dissipation devices is the key point that it
may adversely make analysis and design process complicated. This
effect may be generally represented by Equivalent Viscous Damping
(EVD). The equivalent viscous damping might be obtained from the
expected hysteretic behavior regarding to the design or maximum
considered displacement of a structure. In this paper, the hysteretic
damping coefficient of a steel Moment Resisting Frame (MRF),
which its performance is enhanced by a Buckling Restrained Brace
(BRB) system has been evaluated. Having foresight of damping
fraction between BRB and MRF is inevitable for seismic design
procedures like Direct Displacement-Based Design (DDBD) method.
This paper presents an approach to calculate the damping fraction for
such systems by carrying out the dynamic nonlinear time history
analysis (NTHA) under harmonic loading, which is tuned to the
natural system frequency. Two MRF structures, one equipped with
BRB and the other without BRB are simultaneously studied.
Extensive analysis shows that proportion of each system damping
fraction may be calculated by its shear story portion. In this way,
contribution of each BRB in the floors and their general contribution
in the structural performance may be clearly recognized, in advance.
Abstract: In this study, an Artificial Neural Network (ANN)
analytical method has been developed for analyzing earthquake
performances of the Reinforced Concrete (RC) buildings. 66 RC
buildings with four to ten storeys were subjected to performance
analysis according to the parameters which are the existing material,
loading and geometrical characteristics of the buildings. The selected
parameters have been thought to be effective on the performance of
RC buildings. In the performance analyses stage of the study, level of
performance possible to be shown by these buildings in case of an
earthquake was determined on the basis of the 4-grade performance
levels specified in Turkish Earthquake Code-2007 (TEC-2007). After
obtaining the 4-grade performance level, selected 23 parameters of
each building have been matched with the performance level. In this
stage, ANN-based fast evaluation algorithm mentioned above made
an economic and rapid evaluation of four to ten storey RC buildings.
According to the study, the prediction accuracy of ANN has been
found about 74%.
Abstract: Passive control methods can be utilized to build
earthquake resistant structures, and also to strengthen the vulnerable
ones. In this paper, we studied the effect of this system in increasing
the ductility and energy dissipation and also modeled the behavior of
this type of eccentric bracing, and compared the hysteresis diagram
of the modeled samples with the laboratory samples. We studied
several samples of frames with vertical shear-links in order to assess
the behavior of this type of eccentric bracing. Each of these samples
was modeled in finite element software ANSYS 9.0, and was
analyzed under the static cyclic loading. It was found that vertical
shear-links have a more stable hysteresis loops. Another analysis
showed that using honeycomb beams as the horizontal beam along
with steel reinforcement has no negative effect on the hysteresis
behavior of the sample.
Abstract: Based on the hypothesis that disaster risk is
constructed socially and historically, this article shows the
importance of keeping alive the historical memory of disaster by
means of architectural and urban heritage conservation. This is
illustrated with three examples of Latin American World Heritage
cities, where disasters like floods and earthquakes have shaped urban
form. Therefore, the study of urban form or "Urban Morphology" is
proposed as a tool to understand and analyze urban transformations
with the documentation of the occurrence of disasters. Lessons
learned from such cities may be useful to reduce disasters risk in
contemporary built environments.
Abstract: The Composite Shear Walls (CSW) with steel encased
profiles can be used as lateral-load resisting systems for buildings
that require considerable large lateral-load capacity. The aim of this
work is to propose the experimental work conducted on CSW having
L section folded plate (L shape steel made-up sections) as
longitudinal reinforcement in boundary regions. The study in this
paper present the experimental test conducted on CSW having L
section folded plate as longitudinal reinforcement in boundary
regions. The tested 1/3 geometric scaled CSW has aspect ratio of 3.2.
L-shape structural steel materials with 2L-19x57x7mm dimensions
were placed in shear wall boundary zones. The seismic behavior of
CSW test specimen was investigated by evaluating and interpreting
the hysteresis curves, envelope curves, rigidity and consumed energy
graphs of this tested element. In addition to this, the experimental
results, deformation and cracking patterns were evaluated, interpreted
and suggestions of the design recommendations were proposed.
Abstract: The goal of the paper is to highlight the effect of the
building design and epicentral distance on the storey lateral
displacements, for several reinforced concrete buildings (6, 9 and 12
stories). These structures are subjected to seismic accelerations from
the Boumerdes earthquake (Algeria, May 21st, Mw = 6.8). Using the
response spectrum method (modal spectral approach), the analysis is
performed in both longitudinal and transverse directions. The
building design is expressed through the fundamental period and
epicentral distance is used to represent the earthquake effect variation
on storey lateral displacements and interstory drift for the considered
buildings.
Abstract: This article aims to analyze the static stability and
pseudostatic slope by using different methods such as: Bishop
method, Junbu, Ordinary, Morgenstern-price and GLE. The two
dimensional modeling of slope stability under various loading as: the
earthquake effect, the water level and road mobile charges. The
results show that the slope is stable in the static case without water,
but in other cases, the slope lost its stability and give unstable. The
calculation of safety factor is to evaluate the stability of the slope
using the limit equilibrium method despite the difference between the
results obtained by these methods that do not rely on the same
assumptions. In the end, the results of this study illuminate well the
influence of the action of water, moving loads and the earthquake on
the stability of the slope.
Abstract: The degradation of concrete due to various hygrochemo-
mechanical actions is inevitable for the structures particularly
built to store water. Therefore, it is essential to determine the material
properties of dam-like structures due to ageing to predict the behavior
of such structures after a certain age. The degraded material
properties are calculated by introducing isotropic degradation index.
The predicted material properties are used to study the behavior of
aged dam at different ages. The dam is modeled by finite elements
and displacement and is considered as an unknown variable. The
parametric study reveals that the displacement is quite larger for
comparatively lower design life of the structure because the
degradation of elastic properties depends on the design life of the
dam. The stresses in dam cam be unexpectedly large at any age with
in the design life. The outcomes of the present study indicate the
importance of the consideration ageing effect of concrete exposed to
water for the safe design of dam throughout its life time.
Abstract: Masonry infill walls are inevitable in the selfsupporting
structures, but their contribution in the resistance to
earthquake loads is generally neglected in the structural analyses. The
principal aim of this work through a numerical study of masonry
infill walls behavior in structures subjected to horizontal load is to
propose by finite elements numerical modeling, a more reliable
approach, faster and close to reality. In this study, 3D Finite Element
Analysis was developed to study the behavior of masonry infill walls
in structures subjected to horizontal load; the finite element software
being used was ABAQUS, it is observed that more rigidity of the
masonry filling is significant, more the structure is rigid, we can so
conclude that the filling brings an additional rigidity to the structure
not to be neglected; it is also observed that when the framework is
subjected to horizontal loads, the framework separates from the
filling on the level of the tended diagonal.
Abstract: In this paper, a summary of analytical and
experimental studies into the behavior of a new hysteretic damper,
designed for seismic protection of structures is presented. The Multidirectional
Torsional Hysteretic Damper (MRSD) is a patented
invention in which a symmetrical arrangement of identical cylindrical
steel cores is so configured as to yield in torsion while the structure
experiences planar movements due to earthquake shakings. The new
device has certain desirable properties. Notably, it is characterized by
a variable and controllable-via-design post-elastic stiffness. The
mentioned property is a result of MRSD’s kinematic configuration
which produces this geometric hardening, rather than being a
secondary large-displacement effect. Additionally, the new system is
capable of reaching high force and displacement capacities, shows
high levels of damping, and very stable cyclic response. The device
has gone through many stages of design refinement, multiple
prototype verification tests and development of design guide-lines
and computer codes to facilitate its implementation in practice.
Practicality of the new device, as offspring of an academic sphere, is
assured through extensive collaboration with industry in its final
design stages, prototyping and verification test programs.
Abstract: Damage status of RC buildings is greatly influenced
by the characteristics of the imposed ground motion. Peak Ground
Acceleration and frequency contents are considered the main two
factors that affect ground motion characteristics; hence, affecting the
seismic response of RC structures and consequently their damage
state. A detailed investigation on the combined effects of these two
factors on damage assessment of RC buildings is carried out. Twenty
one earthquake records are analyzed and arranged into three groups,
according to their frequency contents. These records are used in an
investigation to define the expected damage state that would be
attained by RC buildings, if subjected to varying ground motion
characteristics. The damage assessment is conducted through
examining drift ratios and damage indices of the overall structure and
the significant structural components of RC building. Base and story
shear of RC building model, are also investigated, for cases when the
model is subjected to the chosen twenty one earthquake records.
Nonlinear dynamic analyses are performed on a 2-dimensional model
of a 12-story RC building.
Abstract: In this paper, we propose a system for preventing gas
risks through the use of wireless communication modules and
intelligent gas safety appliances. Our system configuration consists of
an automatic extinguishing system, detectors, a wall-pad, and a
microcomputer controlled micom gas meter to monitor gas flow and
pressure as well as the occurrence of earthquakes. The automatic fire
extinguishing system checks for both combustible gaseous leaks and
monitors the environmental temperature, while the detector array
measures smoke and CO gas concentrations. Depending on detected
conditions, the micom gas meter cuts off an inner valve and generates
a warning, the automatic fire-extinguishing system cuts off an external
valve and sprays extinguishing materials, or the sensors generate
signals and take further action when smoke or CO are detected.
Information on intelligent measures taken by the gas safety appliances
and sensors are transmitted to the wall-pad, which in turn relays this as
real time data to a server that can be monitored via an external network
(BcN) connection to a web or mobile application for the management
of gas safety. To validate this smart-home gas management system, we
field-tested its suitability for use in Korean apartments under several
scenarios.
Abstract: The seismic risk mitigation from the perspective of
the old buildings stock is truly essential in Algerian urban areas,
particularly those located in seismic prone regions, such as Annaba
city, and which the old buildings present high levels of degradation
associated with no seismic strengthening and/or rehabilitation
concerns. In this sense, the present paper approaches the issue of the
seismic vulnerability assessment of old masonry building stocks
through the adaptation of a simplified methodology developed for a
European context area similar to that of Annaba city, Algeria.
Therefore, this method is used for the first level of seismic
vulnerability assessment of the masonry buildings stock of the old
city center of Annaba. This methodology is based on a vulnerability
index that is suitable for the evaluation of damage and for the
creation of large-scale loss scenarios. Over 380 buildings were
evaluated in accordance with the referred methodology and the
results obtained were then integrated into a Geographical Information
System (GIS) tool. Such results can be used by the Annaba city
council for supporting management decisions, based on a global view
of the site under analysis, which led to more accurate and faster
decisions for the risk mitigation strategies and rehabilitation plans.
Abstract: This study presented to reduce earthquake damage and
emergency rehabilitation of critical structures such as schools, hightech
factories, and hospitals due to strong ground motions associated
with climate changes. Regarding recent trend, a strong earthquake
causes serious damage to critical structures and then the critical
structure might be influenced by sequence aftershocks (or tsunami)
due to fault plane adjustments. Therefore, in order to improve seismic
performance of critical structures, retrofitted or strengthening study
of the structures under aftershocks sequence after emergency
rehabilitation of the structures subjected to strong earthquakes is
widely carried out. Consequently, this study used composite material
for emergency rehabilitation of the structure rather than concrete and
steel materials because of high strength and stiffness, lightweight,
rapid manufacturing, and dynamic performance. Also, this study was
to develop or improve the seismic performance or seismic retrofit of
critical structures subjected to strong ground motions and earthquake
aftershocks, by utilizing GFRP-Corrugated Infill Panels (GCIP).
Abstract: The present research work investigates the seismic
response of reinforced concrete (RC) frame building considering the
effect of modeling masonry infill (MI) walls. The seismic behavior of
a residential 6-storey RC frame building, considering and ignoring
the effect of masonry, is numerically investigated using response
spectrum (RS) analysis. The considered herein building is designed
as a moment resisting frame (MRF) system following the Egyptian
code (EC) requirements. Two developed models in terms of bare
frame and infill walls frame are used in the study. Equivalent
diagonal strut methodology is used to represent the behavior of infill
walls, whilst the well-known software package ETABS is used for
implementing all frame models and performing the analysis. The
results of the numerical simulations such as base shear,
displacements, and internal forces for the bare frame as well as the
infill wall frame are presented in a comparative way. The results of
the study indicate that the interaction between infill walls and frames
significantly change the responses of buildings during earthquakes
compared to the results of bare frame building model. Specifically,
the seismic analysis of RC bare frame structure leads to
underestimation of base shear and consequently damage or even
collapse of buildings may occur under strong shakings. On the other
hand, considering infill walls significantly decrease the peak floor
displacements and drifts in both X and Y-directions.