Abstract: Measuring the Electrocardiogram (ECG) signal is an
essential process for the diagnosis of the heart diseases. The ECG
signal has the information of the degree of how much the heart
performs its functions. In medical diagnosis and treatment systems,
Decision Support Systems processing the ECG signal are being
developed for the use of clinicians while medical examination. In this
study, a modular wireless ECG (WECG) measuring and recording
system using a single board computer and e-Health sensor platform
is developed. In this designed modular system, after the ECG signal
is taken from the body surface by the electrodes first, it is filtered and
converted to digital form. Then, it is recorded to the health database
using Wi-Fi communication technology. The real time access of the
ECG data is provided through the internet utilizing the developed
web interface.
Abstract: To evaluate the factors which predetermine the
coronary artery disease in patients having positive Exercise Tolerance
Test (ETT) that is treadmill results and coronary artery findings. This
descriptive study was conducted at Department of Cardiology,
Ibrahim Cardiac Hospital & Research Institute, Dhaka, Bangladesh
from 1st January, 2014 to 31st August, 2014. All patients who had
done ETT (treadmill) for chest pain diagnosis were studied. One
hundred and four patients underwent coronary angiogram after
positive treadmill result. Patients were divided into two groups
depending upon the angiographic findings, i.e. true positive and false
positive. Positive treadmill test patients who have coronary artery
involvement these are called true positive and who have no
involvement they are called false positive group. Both groups were
compared with each other. Out of 104 patients, 81 (77.9%) patients
had true positive ETT and 23 (22.1%) patients had false positive
ETT. The mean age of patients in positive ETT was 53.46± 8.06
years and male mean age was 53.63±8.36 years and female was
52.87±7.0 years. Sixty nine (85.19%) male patients and twelve
(14.81%) female patients had true positive ETT, whereas 15
(65.21%) males and 8 (34.79%) females had false positive ETT, this
was statistically significant (p
Abstract: In this study, it was tried to identify some heart rhythm disorders by electrocardiography (ECG) data that is taken from MIT-BIH arrhythmia database by subtracting the required features, presenting to artificial neural networks (ANN), artificial immune systems (AIS), artificial neural network based on artificial immune system (AIS-ANN) and particle swarm optimization based artificial neural network (PSO-NN) classifier systems. The main purpose of this study is to evaluate the performance of hybrid AIS-ANN and PSO-ANN classifiers with regard to the ANN and AIS. For this purpose, the normal sinus rhythm (NSR), atrial premature contraction (APC), sinus arrhythmia (SA), ventricular trigeminy (VTI), ventricular tachycardia (VTK) and atrial fibrillation (AF) data for each of the RR intervals were found. Then these data in the form of pairs (NSR-APC, NSR-SA, NSR-VTI, NSR-VTK and NSR-AF) is created by combining discrete wavelet transform which is applied to each of these two groups of data and two different data sets with 9 and 27 features were obtained from each of them after data reduction. Afterwards, the data randomly was firstly mixed within themselves, and then 4-fold cross validation method was applied to create the training and testing data. The training and testing accuracy rates and training time are compared with each other.
As a result, performances of the hybrid classification systems, AIS-ANN and PSO-ANN were seen to be close to the performance of the ANN system. Also, the results of the hybrid systems were much better than AIS, too. However, ANN had much shorter period of training time than other systems. In terms of training times, ANN was followed by PSO-ANN, AIS-ANN and AIS systems respectively. Also, the features that extracted from the data affected the classification results significantly.
Abstract: The proposed method is to study and analyze Electrocardiograph (ECG) waveform to detect abnormalities present with reference to P, Q, R and S peaks. The first phase includes the acquisition of real time ECG data. In the next phase, generation of signals followed by pre-processing. Thirdly, the procured ECG signal is subjected to feature extraction. The extracted features detect abnormal peaks present in the waveform Thus the normal and abnormal ECG signal could be differentiated based on the features extracted. The work is implemented in the most familiar multipurpose tool, MATLAB. This software efficiently uses algorithms and techniques for detection of any abnormalities present in the ECG signal. Proper utilization of MATLAB functions (both built-in and user defined) can lead us to work with ECG signals for processing and analysis in real time applications. The simulation would help in improving the accuracy and the hardware could be built conveniently.
Abstract: Noise removal techniques play a vital role in the performance of electrocardiographic (ECG) signal processing systems. ECG signals can be corrupted by various kinds of noise such as baseline wander noise, electromyographic interference, and powerline interference. One of the significant challenges in ECG signal processing is the degradation caused by additive 50 or 60 Hz powerline interference. This work investigates the removal of power line interference and suppression of transient response for filtering noise corrupted ECG signals. We demonstrate the effectiveness of infinite impulse response (IIR) notch filter with time varying pole radius for improving the transient behavior. The temporary change in the pole radius of the filter diminishes the transient behavior. Simulation results show that the proposed IIR filter with time varying pole radius outperforms traditional IIR notch filters in terms of mean square error and transient suppression.
Abstract: Nonstationary and nonlinear signals generated by living complex systems defy traditional mechanistic approaches, which are based on homeostasis. Previous our studies have shown that the evaluation of the interactions of physiological signals by using special analysis methods is suitable for observation of physiological processes. It is demonstrated the possibility of using deep physiological model, based on the interpretation of the changes of the human body’s functional states combined with an application of the analytical method based on matrix theory for the physiological signals analysis, which was applied on high risk cardiac patients. It is shown that evaluation of cardiac signals interactions show peculiar for each individual functional changes at the onset of hemodynamic restoration procedure. Therefore, we suggest that the alterations of functional state of the body, after patients overcome surgery can be complemented by the data received from the suggested approach of the evaluation of functional variables’ interactions.
Abstract: Discrete wavelet transform (DWT) has been widely adopted in biomedical signal processing for denoising, compression
and so on. Choosing a suitable decomposition level (DL) in DWT is of paramount importance to its performance. In this paper, we propose to exploit sparseness of the transformed signals to determine the appropriate DL. Simulation results have shown that the sparseness of transformed signals after DWT increases with the increasing DLs. Additional Monte-Carlo simulation results have verified the effectiveness of sparseness measure in determining the DL.
Abstract: In this paper we introduce an effective ECG compression algorithm based on two dimensional multiwavelet transform. Multiwavelets offer simultaneous orthogonality, symmetry and short support, which is not possible with scalar two-channel wavelet systems. These features are known to be important in signal processing. Thus multiwavelet offers the possibility of superior performance for image processing applications. The SPIHT algorithm has achieved notable success in still image coding. We suggested applying SPIHT algorithm to 2-D multiwavelet transform of2-D arranged ECG signals. Experiments on selected records of ECG from MIT-BIH arrhythmia database revealed that the proposed algorithm is significantly more efficient in comparison with previously proposed ECG compression schemes.
Abstract: This paper presents a new Quality-Controlled, wavelet based, compression method for electrocardiogram (ECG) signals. Initially, an ECG signal is decomposed using the wavelet transform. Then, the resulting coefficients are iteratively thresholded to guarantee that a predefined goal percent root mean square difference (GPRD) is matched within tolerable boundaries. The quantization strategy of extracted non-zero wavelet coefficients (NZWC), according to the combination of RLE, HUFFMAN and arithmetic encoding of the NZWC and a resulting look up table, allow the accomplishment of high compression ratios with good quality reconstructed signals.
Abstract: This paper presents an algorithm based on the
wavelet decomposition, for feature extraction from the ECG signal
and recognition of three types of Ventricular Arrhythmias using
neural networks. A set of Discrete Wavelet Transform (DWT)
coefficients, which contain the maximum information about the
arrhythmias, is selected from the wavelet decomposition. After that a
novel clustering algorithm based on nature inspired algorithm (Ant
Colony Optimization) is developed for classifying arrhythmia types.
The algorithm is applied on the ECG registrations from the MIT-BIH
arrhythmia and malignant ventricular arrhythmia databases. We
applied Daubechies 4 wavelet in our algorithm. The wavelet
decomposition enabled us to perform the task efficiently and
produced reliable results.
Abstract: In this paper, an automatic detecting algorithm for
QRS complex detecting was applied for analyzing ECG recordings
and five criteria for dangerous arrhythmia diagnosing are applied for a
protocol type of automatic arrhythmia diagnosing system. The
automatic detecting algorithm applied in this paper detected the
distribution of QRS complexes in ECG recordings and related
information, such as heart rate and RR interval. In this investigation,
twenty sampled ECG recordings of patients with different pathologic
conditions were collected for off-line analysis. A combinative
application of four digital filters for bettering ECG signals and
promoting detecting rate for QRS complex was proposed as
pre-processing. Both of hardware filters and digital filters were
applied to eliminate different types of noises mixed with ECG
recordings. Then, an automatic detecting algorithm of QRS complex
was applied for verifying the distribution of QRS complex. Finally,
the quantitative clinic criteria for diagnosing arrhythmia were
programmed in a practical application for automatic arrhythmia
diagnosing as a post-processor. The results of diagnoses by automatic
dangerous arrhythmia diagnosing were compared with the results of
off-line diagnoses by experienced clinic physicians. The results of
comparison showed the application of automatic dangerous
arrhythmia diagnosis performed a matching rate of 95% compared
with an experienced physician-s diagnoses.
Abstract: In this paper we are to find the optimum multiwavelet for compression of electrocardiogram (ECG) signals and then, selecting it for using with SPIHT codec. At present, it is not well known which multiwavelet is the best choice for optimum compression of ECG. In this work, we examine different multiwavelets on 24 sets of ECG data with entirely different characteristics, selected from MIT-BIH database. For assessing the functionality of the different multiwavelets in compressing ECG signals, in addition to known factors such as Compression Ratio (CR), Percent Root Difference (PRD), Distortion (D), Root Mean Square Error (RMSE) in compression literature, we also employed the Cross Correlation (CC) criterion for studying the morphological relations between the reconstructed and the original ECG signal and Signal to reconstruction Noise Ratio (SNR). The simulation results show that the Cardinal Balanced Multiwavelet (cardbal2) by the means of identity (Id) prefiltering method to be the best effective transformation. After finding the most efficient multiwavelet, we apply SPIHT coding algorithm on the transformed signal by this multiwavelet.
Abstract: ECG contains very important clinical information about the cardiac activities of the heart. Often the ECG signal needs to be captured for a long period of time in order to identify abnormalities in certain situations. Such signal apart of a large volume often is characterised by low quality due to the noise and other influences. In order to extract features in the ECG signal with time-varying characteristics at first need to be preprocessed with the best parameters. Also, it is useful to identify specific parts of the long lasting signal which have certain abnormalities and to direct the practitioner to those parts of the signal. In this work we present a method based on wavelet transform, standard deviation and variable threshold which achieves 100% accuracy in identifying the ECG signal peaks and heartbeat as well as identifying the standard deviation, providing a quick reference to abnormalities.
Abstract: This paper describes a new method for extracting the fetal heart rate (fHR) and the fetal heart rate variability (fHRV) signal non-invasively using abdominal maternal electrocardiogram (mECG) recordings. The extraction is based on the fundamental frequency (Fourier-s) theorem. The fundamental frequency of the mother-s electrocardiogram signal (fo-m) is calculated directly from the abdominal signal. The heart rate of the fetus is usually higher than that of the mother; as a result, the fundamental frequency of the fetal-s electrocardiogram signal (fo-f) is higher than that of the mother-s (fo-f > fo-m). Notch filters to suppress mother-s higher harmonics were designed; then a bandpass filter to target fo-f and reject fo-m is implemented. Although the bandpass filter will pass some other frequencies (harmonics), we have shown in this study that those harmonics are actually carried on fo-f, and thus have no impact on the evaluation of the beat-to-beat changes (RR intervals). The oscillations of the time-domain extracted signal represent the RR intervals. We have also shown in this study that zero-to-zero evaluation of the periods is more accurate than the peak-to-peak evaluation. This method is evaluated both on simulated signals and on different abdominal recordings obtained at different gestational ages.
Abstract: The method described in this paper deals with the problems of T-wave detection in an ECG. Determining the position of a T-wave is complicated due to the low amplitude, the ambiguous and changing form of the complex. A wavelet transform approach handles these complications therefore a method based on this concept was developed. In this way we developed a detection method that is able to detect T-waves with a sensitivity of 93% and a correct-detection ratio of 93% even with a serious amount of baseline drift and noise.
Abstract: We suggest a novel method to incorporate longterm
redundancy (LTR) in signal time domain compression
methods. The proposition is based on block-sorting and curve
simplification. The proposition is illustrated on the ECG
signal as a post-processor for the FAN method. Test
applications on the new so-obtained FAN+ method using the
MIT-BIH database show substantial improvement of the
compression ratio-distortion behavior for a higher quality
reconstructed signal.
Abstract: In this paper we are to find the optimum
multiwavelet for compression of electrocardiogram (ECG)
signals. At present, it is not well known which multiwavelet is
the best choice for optimum compression of ECG. In this
work, we examine different multiwavelets on 24 sets of ECG
data with entirely different characteristics, selected from MITBIH
database. For assessing the functionality of the different
multiwavelets in compressing ECG signals, in addition to
known factors such as Compression Ratio (CR), Percent Root
Difference (PRD), Distortion (D), Root Mean Square Error
(RMSE) in compression literature, we also employed the
Cross Correlation (CC) criterion for studying the
morphological relations between the reconstructed and the
original ECG signal and Signal to reconstruction Noise Ratio
(SNR). The simulation results show that the cardbal2 by the
means of identity (Id) prefiltering method to be the best
effective transformation.
Abstract: In this paper, we study the application of Extreme
Learning Machine (ELM) algorithm for single layered feedforward
neural networks to non-linear chaotic time series problems. In this
algorithm the input weights and the hidden layer bias are randomly
chosen. The ELM formulation leads to solving a system of linear
equations in terms of the unknown weights connecting the hidden
layer to the output layer. The solution of this general system of
linear equations will be obtained using Moore-Penrose generalized
pseudo inverse. For the study of the application of the method we
consider the time series generated by the Mackey Glass delay
differential equation with different time delays, Santa Fe A and
UCR heart beat rate ECG time series. For the choice of sigmoid,
sin and hardlim activation functions the optimal values for the
memory order and the number of hidden neurons which give the
best prediction performance in terms of root mean square error are
determined. It is observed that the results obtained are in close
agreement with the exact solution of the problems considered
which clearly shows that ELM is a very promising alternative
method for time series prediction.
Abstract: This paper presents the work of signal discrimination
specifically for Electrocardiogram (ECG) waveform. ECG signal is
comprised of P, QRS, and T waves in each normal heart beat to
describe the pattern of heart rhythms corresponds to a specific
individual. Further medical diagnosis could be done to determine any
heart related disease using ECG information. The emphasis on QRS
Complex classification is further discussed to illustrate the
importance of it. Pan-Tompkins Algorithm, a widely known
technique has been adapted to realize the QRS Complex
classification process. There are eight steps involved namely
sampling, normalization, low pass filter, high pass filter (build a band
pass filter), derivation, squaring, averaging and lastly is the QRS
detection. The simulation results obtained is represented in a
Graphical User Interface (GUI) developed using MATLAB.
Abstract: A new, combinatorial model for analyzing and inter-
preting an electrocardiogram (ECG) is presented. An application of
the model is QRS peak detection. This is demonstrated with an
online algorithm, which is shown to be space as well as time efficient.
Experimental results on the MIT-BIH Arrhythmia database show that
this novel approach is promising. Further uses for this approach are
discussed, such as taking advantage of its small memory requirements
and interpreting large amounts of pre-recorded ECG data.