Abstract: Zymomonas mobilis is known as an example of the
uncoupled growth phenomenon. This microorganism also has a
unique metabolism that degrades glucose by the Entner–Doudoroff
(ED) pathway. In this paper, a genome-scale metabolic model
including 434 genes, 757 reactions and 691 metabolites was
reconstructed to simulate uncoupled growth and study its effect on
flux distribution in the central metabolism. The model properly
predicted that ATPase was activated in experimental growth yields of
Z. mobilis. Flux distribution obtained from model indicates that the
major carbon flux passed through ED pathway that resulted in the
production of ethanol. Small amounts of carbon source were entered
into pentose phosphate pathway and TCA cycle to produce biomass
precursors. Predicted flux distribution was in good agreement with
experimental data. The model results also indicated that Z. mobilis
metabolism is able to produce biomass with maximum growth yield
of 123.7 g (mol glucose)-1 if ATP synthase is coupled with growth
and produces 82 mmol ATP gDCW-1h-1. Coupling the growth and
energy reduced ethanol secretion and changed the flux distribution to
produce biomass precursors.
Abstract: A recently developed one-equation turbulence model
has been successfully applied to simulate turbulent flows with
various complexities. The model, which is based on the
transformation of the k-ε closure, is wall-distance free and equipped
with lagging destruction/dissipation terms. Test cases included shockboundary-
layer interaction flows over the NACA 0012 airfoil, an
axisymmetric bump, and the ONERA M6 wing. The capability of the
model to operate in a Scale Resolved Simulation (SRS) mode is
demonstrated through the simulation of a massive flow separation
over a circular cylinder at Re= 1.2 x106. An assessment of the results
against available experiments Menter (k-ε)1Eq and the Spalart-
Allmaras model that belongs to the single equation closure family is
made.
Abstract: Glass Fiber Reinforced Polymer (GFRP) is a major evolution for energy dissipation when used as infill material for seismic retrofitting of steel frame, a basic PMC infill wall system consists of two GFRP laminates surrounding an infill of foam core. This paper presents numerical analysis in terms of buckling resistance of GFRP sandwich infill panels system under the influence of environment temperature and stacking sequence of laminate skin. Mode of failure under in-plane compression is studied by means of numerical analysis with ABAQUS platform. Parameters considered in this study are contact length between infill and frame, laminate stacking sequence of GFRP skin and variation of mechanical properties due to increment of temperature. The analysis is done with four cases of simple stacking sequence over a range of temperature. The result showed that both the effect of temperature and stacking sequence alter the performance of entire panel system. The rises of temperature resulted in the decrements of the panel’s strength. This is due to the polymeric nature of this material. Additionally, the contact length also displays the effect on the performance of infill panel. Furthermore, the laminate stiffness can be modified by orientation of laminate, which can increase the infill panel strength. Hence, optimal performance of the entire panel system can be obtained by comparing different cases of stacking sequence.
Abstract: According to current seismic codes the structures are calculated using the capacity design procedure based on the concept of shear at the base depending on several parameters including behavior factor which is considered to be the most important parameter. The behavior factor allows designing the structure when it is at its ultimate limit state taking into account its energy dissipation through its plastic deformation. The aim of the present study is to assess the basic parameters on which is composed the behavior factor among them the reduction factor due to ductility, and those due to redundancy and the overstrength for steel moment-resisting frames of different heights and regular configuration. Analyses are conducted on these frames using the nonlinear static method where the effect of some parameters on the behavior factor, such as the number of stories and the number of spans, are taken into account. The results show that the behavior factor is rather sensitive to the variation of the number of stories and bays.
Abstract: Data driven dynamic logic is the high speed dynamic circuit with low area. The clock of the dynamic circuit is removed and data drives the circuit instead of clock for precharging purpose. This data driven dynamic nand gate is given static forward substrate biasing of Vsupply/2 as well as the substrate bias is connected to the input data, resulting in dynamic substrate bias. The dynamic substrate bias gives the shortest propagation delay with a penalty on the power dissipation. Propagation delay is reduced by 77.8% compared to the normal reverse substrate bias Data driven dynamic nand. Also dynamic substrate biased D3nand’s propagation delay is reduced by 31.26% compared to data driven dynamic nand gate with static forward substrate biasing of Vdd/2. This data driven dynamic nand gate with dynamic body biasing gives us the highest speed with no area penalty and finds its applications where power penalty is acceptable. Also combination of Dynamic and static Forward body bias can be used with reduced propagation delay compared to static forward biased circuit and with comparable increase in an average power. The simulations were done on hspice simulator with 22nm High-k metal gate strained Si technology HP models of Arizona State University, USA.
Abstract: Quad Flat No-Lead (QFN) packages have become very popular for turners, converters and audio amplifiers, among others applications, needing efficient power dissipation in small footprints. Since semiconductor junction temperature (TJ) is a critical parameter in the product quality. And to ensure that die temperature does not exceed the maximum allowable TJ, a thermal analysis conducted in an earlier development phase is essential to avoid repeated re-designs process with huge losses in cost and time. A simulation tool capable to estimate die temperature of components with QFN package was developed. Allow establish a non-empirical way to define an acceptance criterion for amount of voids in solder interface between its exposed pad and Printed Circuit Board (PCB) to be applied during industrialization process, and evaluate the impact of PCB designs parameters. Targeting PCB layout designer as an end user for the application, a user-friendly interface (GUI) was implemented allowing user to introduce design parameters in a convenient and secure way and hiding all the complexity of finite element simulation process. This cost effective tool turns transparent a simulating process and provides useful outputs after acceptable time, which can be adopted by PCB designers, preventing potential risks during the design stage and make product economically efficient by not oversizing it. This article gathers relevant information related to the design and implementation of the developed tool, presenting a parametric study conducted with it. The simulation tool was experimentally validated using a Thermal-Test-Chip (TTC) in a QFN open-cavity, in order to measure junction temperature (TJ) directly on the die under controlled and knowing conditions. Providing a short overview about standard thermal solutions and impacts in exposed pad packages (i.e. QFN), accurately describe the methods and techniques that the system designer should use to achieve optimum thermal performance, and demonstrate the effect of system-level constraints on the thermal performance of the design.
Abstract: In this paper, shear behavior of reconstituted clay reinforced with varying diameter of sand compaction piles with area replacement-ratio (as) of 6.25, 10.24, 16, 20.25 and 64% in 100mm diameter and 200mm long clay specimens is modeled using consolidated drained and undrained triaxial tests under different confining pressures ranging from 50kPa to 575kPa. The test results show that the stress-strain behavior of the clay was highly influenced by the presence of SCP. The insertion of SCPs into soft clay has shown to have a positive effect on the load carrying capacity of the clay, resulting in a composite soil mass that has greater shear strength and improved stiffness compared to the unreinforced clay due to increased reinforcement area ratio. In addition, SCP also acts as vertical drain in the clay thus accelerating the dissipation of excess pore water pressures that are generated during loading by shortening the drainage path and activating radial drainage, thereby reducing post-construction settlement. Thus, sand compaction piles currently stand as one of the most viable and practical techniques for improving the mechanical properties of soft clays.
Abstract: In this paper, a genetic-neural-network (GNN) based large-signal model for GaN HEMTs is presented along with its parameters extraction procedure. The model is easy to construct and implement in CAD software and requires only DC and S-parameter measurements. An improved decomposition technique is used to model self-heating effect. Two GNN models are constructed to simulate isothermal drain current and power dissipation, respectively. The two model are then composed to simulate the drain current. The modeling procedure was applied to a packaged GaN-on-Si HEMT and the developed model is validated by comparing its large-signal simulation with measured data. A very good agreement between the simulation and measurement is obtained.
Abstract: In many practical situations, bubbles are dispersed in a
liquid phase. Understanding these complex bubbly flows is therefore
a key issue for applications such as shell and tube heat exchangers,
mineral flotation and oxidation in water treatment. Although a large
body of work exists for bubbles rising in an unbounded medium,
that of bubbles rising in constricted geometries has received less
attention. The particular case of a bubble sliding underneath an
inclined surface is common to two-phase flow systems. The current
study intends to expand this knowledge by performing experiments
to quantify the streamwise flow structures associated with a single
sliding air bubble under an inclined surface in quiescent water. This
is achieved by means of two-dimensional, two-component particle
image velocimetry (PIV), performed with a continuous wave laser
and high-speed camera. PIV vorticity fields obtained in a plane
perpendicular to the sliding surface show that there is significant bulk
fluid motion away from the surface. The associated momentum of the
bubble means that this wake motion persists for a significant time
before viscous dissipation. The magnitude and direction of the flow
structures in the streamwise measurement plane are found to depend
on the point on its path through which the bubble enters the plane.
This entry point, represented by a phase angle, affects the nature and
strength of the vortical structures. This study reconstructs the vorticity
field in the wake of the bubble, converting the field at different
instances in time to slices of a large-scale wake structure. This is, in
essence, Taylor’s ”frozen turbulence” hypothesis. Applying this to the
vorticity fields provides a pseudo three-dimensional representation
from 2-D data, allowing for a more intuitive understanding of the
bubble wake. This study provides insights into the complex dynamics
of a situation common to many engineering applications, particularly
shell and tube heat exchangers in the nucleate boiling regime.
Abstract: Non-linear dynamic time history analysis is
considered as the most advanced and comprehensive analytical
method for evaluating the seismic response and performance of
multi-degree-of-freedom building structures under the influence of
earthquake ground motions. However, effective and accurate
application of the method requires the implementation of advanced
hysteretic constitutive models of the various structural components
including masonry infill panels. Sophisticated computational research
tools that incorporate realistic hysteresis models for non-linear
dynamic time-history analysis are not popular among the professional
engineers as they are not only difficult to access but also complex and
time-consuming to use. In addition, commercial computer programs
for structural analysis and design that are acceptable to practicing
engineers do not generally integrate advanced hysteretic models
which can accurately simulate the hysteresis behavior of structural
elements with a realistic representation of strength degradation,
stiffness deterioration, energy dissipation and ‘pinching’ under cyclic
load reversals in the inelastic range of behavior. In this scenario,
push-over or non-linear static analysis methods have gained
significant popularity, as they can be employed to assess the seismic
performance of building structures while avoiding the complexities
and difficulties associated with non-linear dynamic time-history
analysis. “Push-over” or non-linear static analysis offers a practical
and efficient alternative to non-linear dynamic time-history analysis
for rationally evaluating the seismic demands. The present paper is
based on the analytical investigation of the effect of distribution of
masonry infill panels over the elevation of planar masonry infilled
reinforced concrete [R/C] frames on the seismic demands using the
capacity spectrum procedures implementing nonlinear static analysis
[pushover analysis] in conjunction with the response spectrum
concept. An important objective of the present study is to numerically
evaluate the adequacy of the capacity spectrum method using
pushover analysis for performance based design of masonry infilled
R/C frames for near-field earthquake ground motions.
Abstract: In the present study, analysis of heat transfer is carried
out in the slip flow region for the fluid flowing between two parallel
plates by employing the asymmetric heat fluxes at surface of the
plates. The flow is assumed to be hydrodynamically and thermally
fully developed for the analysis. The second order velocity slip and
viscous dissipation effects are considered for the analysis. Closed
form expressions are obtained for the Nusselt number as a function of
Knudsen number and modified Brinkman number. The limiting
condition of the present prediction for Kn = 0, Kn2 = 0, and Brq1 = 0
is considered and found to agree well with other analytical results.
Abstract: Nowadays, energy dissipation devices are commonly
used in structures. High rate of energy absorption during earthquakes
is the benefit of using such devices, which results in damage
reduction of structural elements, specifically columns. The hysteretic
damping capacity of energy dissipation devices is the key point that it
may adversely make analysis and design process complicated. This
effect may be generally represented by Equivalent Viscous Damping
(EVD). The equivalent viscous damping might be obtained from the
expected hysteretic behavior regarding to the design or maximum
considered displacement of a structure. In this paper, the hysteretic
damping coefficient of a steel Moment Resisting Frame (MRF),
which its performance is enhanced by a Buckling Restrained Brace
(BRB) system has been evaluated. Having foresight of damping
fraction between BRB and MRF is inevitable for seismic design
procedures like Direct Displacement-Based Design (DDBD) method.
This paper presents an approach to calculate the damping fraction for
such systems by carrying out the dynamic nonlinear time history
analysis (NTHA) under harmonic loading, which is tuned to the
natural system frequency. Two MRF structures, one equipped with
BRB and the other without BRB are simultaneously studied.
Extensive analysis shows that proportion of each system damping
fraction may be calculated by its shear story portion. In this way,
contribution of each BRB in the floors and their general contribution
in the structural performance may be clearly recognized, in advance.
Abstract: Linear stability analysis of double diffusive convection
in a horizontal porous layer saturated with fluid is examined by
considering the effects of viscous dissipation, concentration based
internal heat source and vertical throughflow. The basic steady
state solution for Governing equations is derived. Linear stability
analysis has been implemented numerically by using shooting
and Runge-kutta methods. Critical thermal Rayleigh number Rac
is obtained for various values of solutal Rayleigh number Sa,
vertical Peclet number Pe, Gebhart number Ge, Lewis number
Le and measure of concentration based internal heat source
γ. It is observed that Ge has destabilizing effect for upward
throughflow and stabilizing effect for downward throughflow. And
γ has considerable destabilizing effect for upward throughflow and
insignificant destabilizing effect for downward throughflow.
Abstract: Passive control methods can be utilized to build
earthquake resistant structures, and also to strengthen the vulnerable
ones. In this paper, we studied the effect of this system in increasing
the ductility and energy dissipation and also modeled the behavior of
this type of eccentric bracing, and compared the hysteresis diagram
of the modeled samples with the laboratory samples. We studied
several samples of frames with vertical shear-links in order to assess
the behavior of this type of eccentric bracing. Each of these samples
was modeled in finite element software ANSYS 9.0, and was
analyzed under the static cyclic loading. It was found that vertical
shear-links have a more stable hysteresis loops. Another analysis
showed that using honeycomb beams as the horizontal beam along
with steel reinforcement has no negative effect on the hysteresis
behavior of the sample.
Abstract: Concrete is strong in compression however weak in
tension. The tensile strength as well as ductile property of concrete
could be improved by addition of short dispersed fibers. Polyethylene
terephthalate (PET) fiber obtained from hand cutting or mechanical
slitting of plastic sheets generally used as discrete reinforcement in
substitution of steel fiber. PET fiber obtained from the former process
is in the form of straight slit sheet pattern that impart weaker
mechanical bonding behavior in the concrete matrix. To improve the
limitation of straight slit sheet fiber the present study considered two
additional geometry of fiber namely (a) flattened end slit sheet and
(b) deformed slit sheet. The mix for plain concrete was design for a
compressive strength of 25 MPa at 28 days curing time with a watercement
ratio of 0.5. Cylindrical and beam specimens with 0.5% fibers
volume fraction and without fibers were cast to investigate the
influence of geometry on the mechanical properties of concrete. The
performance parameters mainly studied include flexural strength,
splitting tensile strength, compressive strength and ultrasonic pulse
velocity (UPV). Test results show that geometry of fiber has a
marginal effect on the workability of concrete. However, it plays a
significant role in achieving a good compressive and tensile strength
of concrete. Further, significant improvement in term of flexural and
energy dissipation capacity were observed from other fibers as
compared to the straight slit sheet pattern. Also, the inclusion of PET
fiber improved the ability in absorbing energy in the post-cracking
state of the specimen as well as no significant porous structures.
Abstract: These days, the industrial trend is moving away from heavy and bulky passive components to power converter systems that use more and more semiconductor elements. Also, it is difficult to connect the traditional converters to the high and medium voltage. For these reasons, a new family of multilevel inverters has appeared as a solution for working with higher voltage levels. Different modulation topologies like Sinusoidal Pulse Width Modulation (SPWM), Selective Harmonic Elimination Pulse Width Modulation (SHE-PWM) are available for multilevel inverters. In this work, different hybrid modulation techniques which are combination of fundamental frequency modulation and multilevel sinusoidal-modulation are compared. The main characteristic of these modulations are reduction of switching losses with good harmonic performance and balanced power loss dissipation among the device. The proposed hybrid modulation schemes are developed and simulated in Matlab/Simulink for cascaded H-bridge inverter. The results validate the applicability of the proposed schemes for cascaded multilevel inverter.
Abstract: In insulation and cooling of power transformers
various liquids are used. Mineral oils have wide availability and low
cost. However, they have a poor biodegradability potential and lower
fire point in comparison with other insulating liquids. Use of a liquid
having high biodegradability is important due to environmental
consideration. This paper investigates edible corn oil as an alternative
to mineral oil. Various properties of mineral and corn oil like
breakdown voltage, dissipation factor, relative dielectric constant,
power loss and resistivity were measured according to different
standards.
Abstract: While choosing insulating oil, characteristic features
such as thermal cooling, endurance, efficiency and being
environment-friendly should be considered. Mineral oils are referred
as petroleum-based oil. In this study, vegetable oils investigated as an
alternative insulating liquid to mineral oil. Dissipation factor,
breakdown voltage, relative dielectric constant and resistivity
changes with the frequency and voltage of mineral, rapeseed and nut
oils were measured. Experimental studies were performed according
to ASTM D924 and IEC 60156 standards.
Abstract: This study aims to evaluate the effective size, section
and structural characteristics of circular hollow steel (CHS) damper.
CHS damper is among steel dampers which are used widely for
seismic energy dissipation because they are easy to install, maintain
and are inexpensive. CHS damper dissipates seismic energy through
metallic deformation due to the geometrical elasticity of circular shape
and fatigue resistance around connection part. After calculating the
effective size, which is found to be height to diameter ratio of √3,
nonlinear FE analyses were carried out to evaluate the structural
characteristics and effective section (diameter-to-ratio).
Abstract: To mitigate the urban heat island effect has become a
global issue when we are faced with the challenge of climate change.
Through literature review, plant photosynthesis can reduce the carbon
dioxide and mitigate the urban heat island effect to a degree. Because
there are not enough open space and parks, green roof has become an
important policy in Taiwan.
We selected elementary school buildings in northern New Taipei
City as research subjects since elementary schools are asked with
priority to build green roof and important educational place to promote
green roof concept. Testo175-H1 recording device was used to record
the temperature and humidity differences between roof surface and
interior space below roof with and without green roof in the long-term.
We also use questionnaires to investigate the awareness of comfort
level of green roof and sensation of teachers and students of the
elementary schools.
The results indicated that the temperature of roof without greening
was higher than that with greening by about 2°C. But sometimes
during noontime, the temperature of green roof was higher than that of
non-green roof probably because of the character of the accumulation
and dissipation of heat of greening. The temperature of the interior
space below green roof was normally lower than that without green
roof by about 1°C, showing that green roof could lower the
temperature. The humidity of the green roof was higher than the one
without greening also indicated that green roof retained water better.
Teachers liked to combine green roof concept in the curriculum,
and students wished all classes can take turns to maintain the green
roof. Teachers and students whose school had integrated green roof
concept in the curriculum were more willing to participate in the
maintenance work of green roof. Teachers and students who may have
access to and touch the green roof can be more aware of the green roof
benefit. We suggest architects to increase the accessibility and
visibility of green roof, such as use it as a part of the activity space.
This idea can be a reference to the green roof curriculum design.