Abstract: A 3C-2D PIV technique was applied to investigate the swirling flow generated by an axial plus tangential type swirl generator. This work is focused on the near-exit region of an isothermal swirling jet to characterize the effect of swirl on the flow field and to identify the large coherent structures both in unconfined and confined conditions for geometrical swirl number, Sg = 4.6. Effects of the Reynolds number on the flow structure were also studied. The experimental results show significant effects of the confinement on the mean velocity fields and its fluctuations. The size of the recirculation zone was significantly enlarged upon confinement compared to the free swirling jet. Increasing in the Reynolds number further enhanced the recirculation zone. The frequency characteristics have been measured with a capacitive microphone which indicates the presence of periodic oscillation related to the existence of precessing vortex core, PVC. Proper orthogonal decomposition of the jet velocity field was carried out, enabling the identification of coherent structures. The time coefficients of the first two most energetic POD modes were used to reconstruct the phase-averaged velocity field of the oscillatory motion in the swirling flow. The instantaneous minima of negative swirl strength values calculated from the instantaneous velocity field revealed the presence of two helical structures located in the inner and outer shear layers and this structure fade out at an axial location of approximately z/D = 1.5 for unconfined case and z/D = 1.2 for confined case. By phase averaging the instantaneous swirling strength maps, the 3D helical vortex structure was reconstructed.
Abstract: The characteristics of physiological blood flow in human carotid arterial bifurcation model have been numerically studied using a fully coupled fluid-structure interaction (FSI) analysis. This computational model with the fluid-structure interaction is constructed to investigate the flow characteristics and wall shear stress in the carotid artery. As the flow begins to decelerate after the peak flow, a large recirculation zone develops at the non-divider wall of both internal carotid artery (ICA) and external carotid artery (ECA) in FSI model due to the elastic energy stored in the expanding compliant wall. The calculated difference in wall shear stress (WSS) in both Non-FSI and FSI models is a range of between 5 and 11% at the mean WSS. The low WSS corresponds to regions of carotid artery that are more susceptible to atherosclerosis.
Abstract: The central recirculation zone (CRZ) in a swirl
stabilized gas turbine combustor has a dominant effect on the fuel air
mixing process and flame stability. Most of state of the art swirlers
share one disadvantage; the fixed swirl number for the same swirler
configuration. Thus, in a mathematical sense, Reynolds number
becomes the sole parameter for controlling the flow characteristics
inside the combustor. As a result, at low load operation, the
generated swirl is more likely to become feeble affecting the flame
stabilization and mixing process. This paper introduces a new swirler
concept which overcomes the mentioned weakness of the modern
configurations. The new swirler introduces air tangentially and
axially to the combustor through tangential vanes and an axial vanes
respectively. Therefore, it provides different swirl numbers for the
same configuration by regulating the ratio between the axial and
tangential flow momenta. The swirler aerodynamic performance was
investigated using four CFD simulations in order to demonstrate the
impact of tangential to axial flow rate ratio on the CRZ. It was found
that the length of the CRZ is directly proportional to the tangential to
axial air flow rate ratio.
Abstract: This paper presents a cold flow simulation study of a small gas turbine combustor performed using laboratory scale test rig. The main objective of this investigation is to obtain physical insight of the main vortex, responsible for the efficient mixing of fuel and air. Such models are necessary for predictions and optimization of real gas turbine combustors. Air swirler can control the combustor performance by assisting in the fuel-air mixing process and by producing recirculation region which can act as flame holders and influences residence time. Thus, proper selection of a swirler is needed to enhance combustor performance and to reduce NOx emissions. Three different axial air swirlers were used based on their vane angles i.e., 30°, 45°, and 60°. Three-dimensional, viscous, turbulent, isothermal flow characteristics of the combustor model operating at room temperature were simulated via Reynolds- Averaged Navier-Stokes (RANS) code. The model geometry has been created using solid model, and the meshing has been done using GAMBIT preprocessing package. Finally, the solution and analysis were carried out in a FLUENT solver. This serves to demonstrate the capability of the code for design and analysis of real combustor. The effects of swirlers and mass flow rate were examined. Details of the complex flow structure such as vortices and recirculation zones were obtained by the simulation model. The computational model predicts a major recirculation zone in the central region immediately downstream of the fuel nozzle and a second recirculation zone in the upstream corner of the combustion chamber. It is also shown that swirler angles changes have significant effects on the combustor flowfield as well as pressure losses.
Abstract: This paper presents the prediction of air flow,
humidity and temperature patterns in a co-current pilot plant spray
dryer fitted with a pressure nozzle using a three dimensional model.
The modelling was done with a Computational Fluid Dynamic
package (Fluent 6.3), in which the gas phase is modelled as
continuum using the Euler approach and the droplet/ particle phase is
modelled by the Discrete Phase model (Lagrange approach).Good
agreement was obtained with published experimental data where the
CFD simulation correctly predicts a fast downward central flowing
core and slow recirculation zones near the walls. In this work, the
effects of the air flow pattern on droplets trajectories, residence time
distribution of droplets and deposition of the droplets on the wall also
were investigated where atomizing of maltodextrin solution was
used.
Abstract: The flow field within the combustor of scramjet
engine is very complex and poses a considerable challenge in the
design and development of a supersonic combustor with an optimized
geometry. In this paper comprehensive numerical studies on flow
field characteristics of different cavity based scramjet combustors
with transverse injection of hydrogen have been carried out for both
non-reacting and reacting flows. The numerical studies have been
carried out using a validated 2D unsteady, density based 1st-order
implicit k-omega turbulence model with multi-component finite rate
reacting species. The results show a wide variety of flow features
resulting from the interactions between the injector flows, shock
waves, boundary layers, and cavity flows. We conjectured that an
optimized cavity is a good choice to stabilize the flame in the
hypersonic flow, and it generates a recirculation zone in the scramjet
combustor. We comprehended that the cavity based scramjet
combustors having a bearing on the source of disturbance for the
transverse jet oscillation, fuel/air mixing enhancement, and flameholding
improvement. We concluded that cavity shape with
backward facing step and 45o forward ramp is a good choice to get
higher temperatures at the exit compared to other four models of
scramjet combustors considered in this study.
Abstract: Threedimensional numerical simulations are conducted on a full scale CANDU Moderator and Transient variations of the temperature and velocity distributions inside the tank are determined. The results show that the flow and temperature distributions inside the moderator tank are three dimensional and no symmetry plane can be identified.Competition between the upward moving buoyancy driven flows and the downward moving momentum driven flows, results in the formation of circulation zones. The moderator tank operates in the buoyancy driven mode and any small disturbances in the flow or temperature makes the system unstable and asymmetric. Different types of temperature fluctuations are noted inside the tank: (i) large amplitude are at the boundaries between the hot and cold (ii) low amplitude are in the core of the tank (iii) high frequency fluctuations are in the regions with high velocities and (iv) low frequency fluctuations are in the regions with lower velocities.
Abstract: Generally flow behavior in centrifugal fan is observed
to be in a state of instability with flow separation zones on suction
surface as well as near the front shroud. Overall performance of the
diffusion process in a centrifugal fan could be enhanced by
judiciously introducing the boundary layer suction slots. With easy
accessibility of CFD as an analytical tool, an extensive numerical
whole field analysis of the effect of boundary layer suction slots in
discrete regions of suspected separation points is possible. This paper
attempts to explore the effect of boundary layer suction slots
corresponding to various geometrical locations on the impeller with
converging configurations for the slots. The analysis shows that the
converging suction slots located on the impeller blade about 25%
from the trailing edge, significantly improves the static pressure
recovery across the fan. Also it is found that Slots provided at a
radial distance of about 12% from the leading and trailing edges
marginally improve the static pressure recovery across the fan.
Abstract: It is essential to have a uniform and calm flow field
for a settling tank to have high performance. In general, the
recirculation zones always occurred in sedimentation tanks. The
presence of these regions may have different effects. The nonuniformity
of the velocity field, the short-circuiting at the surface and
the motion of the jet at the bed of the tank that occurs because of the
recirculation in the sedimentation layer, are affected by the geometry
of the tank. There are some ways to decrease the size of these dead
zones, which would increase the performance. One of the ways is to
use a suitable baffle configuration. In this study, the presence of
baffle with different position has been investigated by a finite volume
method, with VOF (Volume of Fluid) model. Besides, the k-ε
turbulence model is used in the numerical calculations. The results
indicate that the best position of the baffle is obtained when the
volume of the recirculation region is minimized or is divided to
smaller part and the flow field trend to be uniform in the settling
zone.
Abstract: Cardiovascular diseases, principally atherosclerosis, are responsible for 30% of world deaths. Atherosclerosis is due to the formation of plaque. The fatty plaque may be at risk of rupture, leading typically to stroke and heart attack. The plaque is usually associated with a high degree of lumen reduction, called a stenosis.It is increasingly recognized that the initiation and progression of disease and the occurrence of clinical events is a complex interplay between the local biomechanical environment and the local vascular biology. The aim of this study is to investigate the flow behavior through a stenosed artery. A physical experiment was performed using an artery model and blood analogue fluid. An axisymmetric model constructed consists of contraction and expansion region that follow a mathematical form of cosine function. A 30% diameter reduction was used in this study. The flow field was measured using particle image velocimetry (PIV). Spherical particles with 20μm diameter were seeded in a water-glycerol-NaCl mixture. Steady flow Reynolds numbers are 250. The area of interest is the region after the stenosis where the flow separation occurs. The velocity field was measured and the velocity gradient was investigated. There was high particle concentration in the recirculation zone. High velocity gradient formed immediately after the stenosis throat created a lift force that enhanced particle migration to the flow separation area.
Abstract: Experimental investigations were carried out in the
Manchester Tidal flow Facility (MTF) to study the flow patterns in
the region around and adjacent to a hypothetical headland in tidal
(oscillatory) ambient flow. The Planar laser-induced fluorescence
(PLIF) technique was used for visualization, with fluorescent dye
released at specific points around the headland perimeter and in its
adjacent recirculation zone. The flow patterns can be generalized into
the acceleration, stable flow and deceleration stages for each halfcycle,
with small variations according to location, which are more
distinct for low Keulegan-Carpenter number (KC) cases. Flow
patterns in the mixing region are unstable and complex, especially in
the recirculation zone. The flow patterns are in agreement with
previous visualizations, and support previous results in steady
ambient flow. It is suggested that the headland lee could be a viable
location for siting of pollutant outfalls.
Abstract: The flow field in a centrifugal fan is highly complex
with flow reversal taking place on the suction side of impeller and
diffuser vanes. Generally performance of the centrifugal fan could be
enhanced by judiciously introducing splitter vanes so as to improve
the diffusion process. An extensive numerical whole field analysis on
the effect of splitter vanes placed in discrete regions of suspected
separation points is possible using CFD. This paper examines the
effect of splitter vanes corresponding to various geometrical
locations on the impeller and diffuser. The analysis shows that the
splitter vanes located near the diffuser exit improves the static
pressure recovery across the diffusing domain to a larger extent. Also
it is found that splitter vanes located at the impeller trailing edge and
diffuser leading edge at the mid-span of the circumferential distance
between the blades show a marginal improvement in the static
pressure recovery across the fan. However, splitters provided near to
the suction side of the impeller trailing edge (25% of the
circumferential gap between the impeller blades towards the suction
side), adversely affect the static pressure recovery of the fan.