Abstract: The LHP is a two-phase device with extremely high
effective thermal conductivity that utilizes the thermodynamic
pressure difference to circulate a cooling fluid. A thermodynamics
analytical model is developed to explore different parameters effects
on a Loop Heat Pipe (LHP).. The effects of pipe length, pipe
diameter, condenser temperature, and heat load are reported. As pipe
length increases and/or pipe diameter decreases, a higher temperature