Abstract: Diabetic Retinopathy (DR) is a severe retinal disease which is caused by diabetes mellitus. It leads to blindness when it progress to proliferative level. Early indications of DR are the appearance of microaneurysms, hemorrhages and hard exudates. In this paper, an automatic algorithm for detection of DR has been proposed. The algorithm is based on combination of several image processing techniques including Circular Hough Transform (CHT), Contrast Limited Adaptive Histogram Equalization (CLAHE), Gabor filter and thresholding. Also, Support Vector Machine (SVM) Classifier is used to classify retinal images to normal or abnormal cases including non-proliferative or proliferative DR. The proposed method has been tested on images selected from Structured Analysis of the Retinal (STARE) database using MATLAB code. The method is perfectly able to detect DR. The sensitivity specificity and accuracy of this approach are 90%, 87.5%, and 91.4% respectively.
Abstract: Aerobatic and military pilots are subjected to high gravitational forces that could cause blackout, physical injuries or death. A CFD simulation using fluid-solid interactions scheme has been conducted to investigate the gravitational effects and hazards inside cerebral aneurysms. Medical data have been used to derive the size and geometry of a simple aneurysm on a T-shaped bifurcation. The results show that gravitational force has no effect on maximum Wall Shear Stress (WSS); hence, it will not cause aneurysm initiation/formation. However, gravitational force cause causes hypertension which could contribute to aneurysm rupture.
Abstract: Diabetic retinopathy is characterized by the development of retinal microaneurysms. The damage can be prevented if disease is treated in its early stages. In this paper, we are comparing Support Vector Machine (SVM) and Naïve Bayes (NB) classifiers for automatic microaneurysm detection in images acquired through non-dilated pupils. The Nearest Neighbor classifier is used as a baseline for comparison. Detected microaneurysms are validated with expert ophthalmologists’ hand-drawn ground-truths. The sensitivity, specificity, precision and accuracy of each method are also compared.
Abstract: This paper presents a customized deformable model
for the segmentation of abdominal and thoracic aortic aneurysms in
CTA datasets. An important challenge in reliably detecting aortic
aneurysm is the need to overcome problems associated with intensity
inhomogeneities and image noise. Level sets are part of an important
class of methods that utilize partial differential equations (PDEs) and
have been extensively applied in image segmentation. A Gaussian
kernel function in the level set formulation, which extracts the local
intensity information, aids the suppression of noise in the extracted
regions of interest and then guides the motion of the evolving contour
for the detection of weak boundaries. The speed of curve evolution
has been significantly improved with a resulting decrease in
segmentation time compared with previous implementations of level
sets. The results indicate the method is more effective than other
approaches in coping with intensity inhomogeneities.
Abstract: Microaneurysm is a key indicator of diabetic retinopathy that can potentially cause damage to retina. Early detection and automatic quantification are the keys to prevent further damage. In this paper, which focuses on automatic microaneurysm detection in images acquired through non-dilated pupils, we present a series of experiments on feature selection and automatic microaneurysm pixel classification. We found that the best feature set is a combination of 10 features: the pixel-s intensity of shade corrected image, the pixel hue, the standard deviation of shade corrected image, DoG4, the area of the candidate MA, the perimeter of the candidate MA, the eccentricity of the candidate MA, the circularity of the candidate MA, the mean intensity of the candidate MA on shade corrected image and the ratio of the major axis length and minor length of the candidate MA. The overall sensitivity, specificity, precision, and accuracy are 84.82%, 99.99%, 89.01%, and 99.99%, respectively.
Abstract: This paper presents a technique for diagnosis of the abdominal aorta aneurysm in magnetic resonance imaging (MRI) images. First, our technique is designed to segment the aorta image in MRI images. This is a required step to determine the volume of aorta image which is the important step for diagnosis of the abdominal aorta aneurysm. Our proposed technique can detect the volume of aorta in MRI images using a new external energy for snakes model. The new external energy for snakes model is calculated from Law-s texture. The new external energy can increase the capture range of snakes model efficiently more than the old external energy of snakes models. Second, our technique is designed to diagnose the abdominal aorta aneurysm by Bayesian classifier which is classification models based on statistical theory. The feature for data classification of abdominal aorta aneurysm was derived from the contour of aorta images which was a result from segmenting of our snakes model, i.e., area, perimeter and compactness. We also compare the proposed technique with the traditional snakes model. In our experiment results, 30 images are trained, 20 images are tested and compared with expert opinion. The experimental results show that our technique is able to provide more accurate results than 95%.
Abstract: Abdominal aortic aneurysms rupture (AAAs) is one of the main causes of death in the world. This is a very complex phenomenon that usually occurs “without previous warning". Currently, criteria to assess the aneurysm rupture risk (peak diameter and growth rate) can not be considered as reliable indicators. In a first approach, the main geometric parameters of aneurysms have been linked into five biomechanical factors. These are combined to obtain a dimensionless rupture risk index, RI(t), which has been validated preliminarily with a clinical case and others from literature. This quantitative indicator is easy to understand, it allows estimating the aneurysms rupture risks and it is expected to be able to identify the one in aneurysm whose peak diameter is less than the threshold value. Based on initial results, a broader study has begun with twelve patients from the Clinic Hospital of Valladolid-Spain, which are submitted to periodic follow-up examinations.
Abstract: Endovascular aneurysm repair is a new and minimally invasive repair for patients with abdominal aortic aneurysm (AAA). This method has potential advantages that are incomparable with other repair methods. However, the enlargement of aneurysm in the absence of endoleak, which is known as endotension, may occur as one of post-operative compliances of this method. Typically, endotension is mainly as a result of pressure transmitted to aneurysm sac by endovascular installed graft. After installation of graft the aneurysm sac reduces significantly but remains non-zero. There are some factors which affect this pressure transmitted. In this study, the geometry features of installed vascular graft have been considered. It is inferred that graft neck angle and iliac bifurcation angle are two factors which can affect the drag force on graft and consequently the pressure transmitted to aneurysm.
Abstract: The recent advances in computational fluid dynamics
(CFD) can be useful in observing the detailed hemodynamics in
cerebral aneurysms for understanding not only their formation and
rupture but also for clinical evaluation and treatment. However,
important hemodynamic quantities are difficult to measure in vivo. In
the present study, an approximate model of normal middle cerebral
artery (MCA) along with two cases consisting broad and narrow
saccular aneurysms are analyzed. The models are generated in
ANSYS WORKBENCH and transient analysis is performed in
ANSYS-CFX. The results obtained are compared for three cases and
agree well with the available literature.
Abstract: This paper presents an application of level sets for the segmentation of abdominal and thoracic aortic aneurysms in CTA
datasets. An important challenge in reliably detecting aortic is the
need to overcome problems associated with intensity
inhomogeneities. Level sets are part of an important class of methods
that utilize partial differential equations (PDEs) and have been extensively applied in image segmentation. A kernel function in the
level set formulation aids the suppression of noise in the extracted
regions of interest and then guides the motion of the evolving contour
for the detection of weak boundaries. The speed of curve evolution
has been significantly improved with a resulting decrease in segmentation time compared with previous implementations of level
sets, and are shown to be more effective than other approaches in
coping with intensity inhomogeneities. We have applied the Courant
Friedrichs Levy (CFL) condition as stability criterion for our algorithm.
Abstract: Recurrence of aneurysm rupture can be attributed to
coil migration and compaction. In order to verify the effects of
hemodynamics on coil compaction and migration, we analyze the
forces and displacements on the coil bundle using a computational
method. Lateral aneurysms partially filled coils are modeled, and
blood flow fields and coil deformations are simulated considering
fluid and solid interaction. Effects of aneurysm neck size and parent
vessel geometry are also investigated. The results showed that coil
deformation was larger in the aneurysms with a wider neck. Parent
vessel geometry and aneurysm neck size also affected mean pressure
force profiles on the coil surface. Pressure forces were higher in wide
neck models with curved parent vessel geometry. Simulation results
showed that coils in the wide neck aneurysm with a curved parent
vessel may be displaced and compacted more easily.
Abstract: In this study, a new and fast algorithm for Ascending
Aorta (AscA) and Descending Aorta (DesA) segmentation is
presented using Computed Tomography Angiography images. This
process is quite important especially at the detection of aortic
plaques, aneurysms, calcification or stenosis. The applied method has
been carried out at four steps. At first step, lung segmentation is
achieved. At the second one, Mediastinum Region (MR) is detected
to use in the segmentation. At the third one, images have been
applied optimal threshold and components which are outside of the
MR were removed. Lastly, identifying and segmentation of AscA and
DesA have been carried out. The performance of the applied method
is found quite well for radiologists and it gives enough results to the
surgeries medically.