Abstract: Reinforced cement concrete is getting extensively used
for construction of different type of structures for the last one century.
During this period, we have constructed many structures like
buildings, bridges, industrial structures, pavement, water tanks etc.
using this construction material. These structures have been created
with huge investment of resources. It is essential to maintain those
structures in functional condition. Since deterioration in RCC
Structures is a common and natural phenomenon it is required to have
a detailed plan, methodology for structural repair and rehabilitation
shall be in place for dealing such issues. It is important to know exact
reason of distress, type of distress and correct method of repair
concrete structures. The different methods of repair are described in
paper according to distress category which can be refereed for repair.
Major finding of the study is that to protect our structure we need to
have maintenance frequency and correct material to be chosen for
repair. Also workmanship during repair needs to be taken utmost care
for quality repair.
Abstract: Lightweight and efficient structures have the aim to
enhance the efficiency of the components in various industries.
Toward this end, composites are one of the most widely used
materials because of durability, high strength and modulus, and low
weight. One type of the advanced composites is grid-stiffened
composite (GSC) structures, which have been extensively considered
in aerospace, automotive, and aircraft industries. They are one of the
top candidates for replacing some of the traditional components,
which are used here. Although there are a good number of published
surveys on the design aspects and fabrication of GSC structures, little
systematic work has been reported on their material modification to
improve their properties, to our knowledge. Matrix modification
using nanoparticles is an effective method to enhance the flexural
properties of the fibrous composites. In the present study, a silanecoupling
agent (3-glycidoxypropyltrimethoxysilane/3-GPTS) was
introduced onto the silica (SiO2) nanoparticle surface and its effects
on the three-point flexural response of isogrid E-glass/epoxy
composites were assessed. Based on the Fourier Transform Infrared
Spectrometer (FTIR) spectra, it was inferred that the 3-GPTS
coupling agent was successfully grafted onto the surface of SiO2
nanoparticles after modification. Flexural test revealed an
improvement of 16%, 14%, and 36% in stiffness, maximum load and
energy absorption of the isogrid specimen filled with 3 wt.% 3-
GPTS/SiO2 compared to the neat one. It would be worth mentioning
that in these structures, considerable energy absorption was observed
after the primary failure related to the load peak. In addition, 3-
GPTMS functionalization had a positive effect on the flexural
behavior of the multiscale isogrid composites. In conclusion, this
study suggests that the addition of modified silica nanoparticles is a
promising method to improve the flexural properties of the gridstiffened
fibrous composite structures.
Abstract: Steel extended end plate bolted connections are
recommended to be widely utilized in special moment-resisting frame
subjected to monotonic loading. Improper design of steel beam to
column connection can lead to the collapse and fatality of structures.
Therefore comprehensive research studies of beam to column
connection design should be carried out. Also the performance and
effect of corrugated on the strength of beam column end plate
connection up to failure under monotonic loading in horizontal
direction is presented in this paper. The non-linear elastic–plastic
behavior has been considered through a finite element analysis using
the multi-purpose software package LUSAS. The effect of vertically
and horizontally types of corrugated web was also investigated.
Abstract: Foundation differential settlement and supported
structure tilting are an occasionally occurred engineering problem.
This may be caused by overloading, changes in ground soil properties
or unsupported nearby excavations. Engineering thinking points
directly toward the logic solution for such problem by uplifting the
settled side. This can be achieved with deep foundation elements
such as micro-piles and macro-piles™, jacked piers, and helical piers,
jet grouted mortar columns, compaction grout columns, cement
grouting or with chemical grouting, or traditional pit underpinning
with concrete and mortar. Although, some of these techniques offer
economic, fast and low noise solutions, many of them are quite the
contrary. For tilted structures, with the limited inclination, it may be much
easier to cause a balancing settlement on the less-settlement side
which shall be done carefully in a proper rate. This principal has been
applied in Leaning Tower of Pisa stabilization with soil extraction
from the ground surface. In this research, the authors attempt to
introduce a new solution with a different point of view. So, the
micro-tunneling technique is presented in here as an intended ground
deformation cause. In general, micro-tunneling is expected to induce
limited ground deformations. Thus, the researchers propose to apply
the technique to form small size ground unsupported holes to produce
the target deformations. This shall be done in four phases: 1.
Application of one or more micro-tunnels, regarding the existing
differential settlement value, under the raised side of the tilted
structure. 2. For each individual tunnel, the lining shall be pulled out
from both sides (from jacking and receiving shafts) in the slow rate.
3. If required, according to calculations and site records, an additional
surface load can be applied on the raised foundation side. 4. Finally, a
strengthening soil grouting shall be applied for stabilization after
adjustment. A finite element based numerical model is presented to simulate
the proposed construction phases for different tunneling positions and
tunnels group. For each case, the surface settlements are calculated
and induced plasticity points are checked. These results show the
impact of the suggested procedure on the tilted structure and its
feasibility. Comparing results also show the importance of the
position selection and tunnels group gradual effect. Thus, a new
engineering solution is presented to one of the structural and
geotechnical engineering challenges.
Abstract: Radio Frequency Identification (RFID) has become a
key technology in the emerging concept of Internet of Things (IoT).
Naturally, business applications would require the deployment of
various RFID systems developed by different vendors that use
different data formats and structures. This heterogeneity poses a
challenge in developing real-life IoT systems with RFID, as
integration is becoming very complex and challenging. Semantic
integration is a key approach to deal with this challenge. To do so,
ontology for RFID systems need to be developed in order to
annotated semantically RFID systems, and hence, facilitate their
integration. Accordingly, in this paper, we propose ontology for
RFID systems. The proposed ontology can be used to semantically
enrich RFID systems, and hence, improve their usage and reasoning.
Abstract: A growing demand is felt today for realistic 3D
models enabling the cognition and popularization of historical-artistic
heritage. Evaluation and preservation of Cultural Heritage is
inextricably connected with the innovative processes of gaining,
managing, and using knowledge. The development and perfecting of
techniques for acquiring and elaborating photorealistic 3D models,
made them pivotal elements for popularizing information of objects
on the scale of architectonic structures.
Abstract: Graphene, a single-atom sheet, has been considered as
the most promising material for making future nanoelectromechanical
systems as well as purely electrical switching with graphene
transistors. Graphene-based devices have advantages in scaled-up
device fabrication due to the recent progress in large area graphene
growth and lithographic patterning of graphene nanostructures. Here
we investigated its mechanical responses of circular graphene
nanoflake under the nanoindentation using classical molecular
dynamics simulations. A correlation between the load and the
indentation depth was constructed. The nanoindented force in this
work was applied to the center point of the circular graphene nanoflake
and then, the resonance frequency could be tuned by a nanoindented
depth. We found the hardening or the softening of the graphene
nanoflake during its nanoindented-deflections, and such properties
were recognized by the shift of the resonance frequency. The
calculated mechanical parameters in the force-vs-deflection plot were
in good agreement with previous experimental and theoretical works.
This proposed schematics can detect the pressure via the deflection
change or/and the resonance frequency shift, and also have great
potential for versatile applications in nanoelectromechanical systems.
Abstract: In this paper, we present an application of Riemannian
geometry for processing non-Euclidean image data. We consider the
image as residing in a Riemannian manifold, for developing a new
method to brain edge detection and brain extraction. Automating this
process is a challenge due to the high diversity in appearance brain
tissue, among different patients and sequences. The main contribution, in this paper, is the use of an edge-based
anisotropic diffusion tensor for the segmentation task by integrating
both image edge geometry and Riemannian manifold (geodesic,
metric tensor) to regularize the convergence contour and extract
complex anatomical structures. We check the accuracy of the
segmentation results on simulated brain MRI scans of single
T1-weighted, T2-weighted and Proton Density sequences. We
validate our approach using two different databases: BrainWeb
database, and MRI Multiple sclerosis Database (MRI MS DB). We
have compared, qualitatively and quantitatively, our approach with
the well-known brain extraction algorithms. We show that using
a Riemannian manifolds to medical image analysis improves the
efficient results to brain extraction, in real time, outperforming the
results of the standard techniques.
Abstract: This article presents the main results of a numerical
investigation on the uncertainty of dynamic response of structures
with statistically correlated random damping Gamma distributed. A
computational method based on a Linear Statistical Model (LSM) is
implemented to predict second order statistics for the response of a
typical industrial building structure. The significance of random
damping with correlated parameters and its implications on the
sensitivity of structural peak response in the neighborhood of a
resonant frequency are discussed in light of considerable ranges of
damping uncertainties and correlation coefficients. The results are
compared to those generated using Monte Carlo simulation
techniques. The numerical results obtained show the importance of
damping uncertainty and statistical correlation of damping
coefficients when obtaining accurate probabilistic estimates of
dynamic response of structures. Furthermore, the effectiveness of the
LSM model to efficiently predict uncertainty propagation for
structural dynamic problems with correlated damping parameters is
demonstrated.
Abstract: The study conducted a simulation of the effect of sea
water to the bonding capacity of GFRP sheet on the concrete beams
using a simulation tank. Fiber reinforced polymer (FRP) has been
developed and applied in many fields civil engineering structures on
the new structures and also for strengthening of the deteriorated
structures. The FRP has advantages such as its corrosion resistance as
well as high tensile strength to weight ratio. Compared to the other
FRP materials, Glass composed FRP (GFRP) is relatively cheaper.
GFRP sheet is applied externally by bonding it on the concrete surface.
The studies regarding the application of GFRP sheet have been
conducted such as strengthening system, bonding behavior of GFRP
sheet including the application as reinforcement in new structures. For
application to the structures with direct contact to sea environment, a
study regarding the effect of sea water to the bonding capacity of
GFRP sheet is important to be clarified. To achieve the objective of the
study, a series of concrete beams strengthened with GFRP sheet on
extreme tension surface were prepared. The beams then were stored on
the sea water tank for six months. Results indicated the bonding
capacity decreased after six month exposed to the sea water.
Abstract: This paper presents the influence of the vertical
seismic component on the non-linear dynamics analysis of three
different structures. The subject structures were analyzed and
designed according to recent codes. This paper considers three types
of buildings: 5-, 10-, and 15-story buildings. The non-linear
dynamics analysis of the structures with assuming elastic-perfectlyplastic
behavior was performed using RAM PERFORM-3D software;
the horizontal component was taken into consideration with and
without the incorporation of the corresponding vertical component.
Dynamic responses obtained for the horizontal component acting
alone were compared with those obtained from the simultaneous
application of both seismic components. The results show that the
effect of the vertical component of ground motion may increase the
axial load significantly in the interior columns and, consequently, the
stories. The plastic mechanisms would be changed. The P-Delta
effect is expected to increase. The punching base plate shear of the
columns should be considered. Moreover, the vertical component
increases the input energy when the structures exhibit inelastic
behavior and are taller.
Abstract: This article presents an alternative collapse capacity
intensity measure in the three elements form which is influenced by
the spectral ordinates at periods longer than that of the first mode
period at near and far source sites. A parameter, denoted by β, is
defined by which the spectral ordinate effects, up to the effective
period (2T1), on the intensity measure are taken into account. The
methodology permits to meet the hazard-levelled target extreme
event in the probabilistic and deterministic forms. A MATLAB code
is developed involving OpenSees to calculate the collapse capacities
of the 8 archetype RC structures having 2 to 20 stories for regression
process. The incremental dynamic analysis (IDA) method is used to
calculate the structure’s collapse values accounting for the element
stiffness and strength deterioration. The general near field set
presented by FEMA is used in a series of performing nonlinear
analyses. 8 linear relationships are developed for the 8structutres
leading to the correlation coefficient up to 0.93. A collapse capacity
near field prediction equation is developed taking into account the
results of regression processes obtained from the 8 structures. The
proposed prediction equation is validated against a set of actual near
field records leading to a good agreement. Implementation of the
proposed equation to the four archetype RC structures demonstrated
different collapse capacities at near field site compared to those of
FEMA. The reasons of differences are believed to be due to
accounting for the spectral shape effects.
Abstract: Structural failure is caused mainly by damage that
often occurs on structures. Many researchers focus on to obtain very
efficient tools to detect the damage in structures in the early state. In
the past decades, a subject that has received considerable attention in
literature is the damage detection as determined by variations in the
dynamic characteristics or response of structures. The study presents
a new damage identification technique. The technique detects the
damage location for the incomplete structure system using output
data only. The method indicates the damage based on the free
vibration test data by using ‘Two Points Condensation (TPC)
technique’. This method creates a set of matrices by reducing the
structural system to two degrees of freedom systems. The current
stiffness matrices obtain from optimization the equation of motion
using the measured test data. The current stiffness matrices compare
with original (undamaged) stiffness matrices. The large percentage
changes in matrices’ coefficients lead to the location of the damage. TPC technique is applied to the experimental data of a simply
supported steel beam model structure after inducing thickness change
in one element, where two cases consider. The method detects the
damage and determines its location accurately in both cases. In
addition, the results illustrate these changes in stiffness matrix can be
a useful tool for continuous monitoring of structural safety using
ambient vibration data. Furthermore, its efficiency proves that this
technique can be used also for big structures.
Abstract: Plate is one of the popular structural elements used in a wide range of industries and structures. They may be subjected to blast loads during explosion events, missile attacks or aircraft attacks. This study is to investigate dynamic responses of the rectangular plate subjected to explosive loads. The effects of material properties and plate thickness on responses of the plate are to be investigated. The compressive pressure is applied to the surface of the plate. Different amounts of thickness in the range from 1mm to 30mm are considered for the plate to evaluate the changes in responses of the plate with respect to plate thickness. Two different properties are considered for the steel. First, the analysis is performed by considering only the elastic-plastic properties for the steel plate. Later on damping is considered to investigate its effects on the responses of the plate. To do analysis, numerical method using a finite element based package ABAQUS is applied. Finally, dynamic responses and graphs showing the relation between maximum displacement of the plate and aim parameters are provided.
Abstract: The seriously damaged structures during earthquakes
show the need and importance of design of reinforced concrete
structures with high ductility. Reinforced concrete beam-column
joints have an important function in all structures. Under seismic
excitation, the beam column joint region is subjected to horizontal
and vertical shear forces whose magnitude is many times higher than
the adjacent beam and column. Strength and ductility of structures
depends mainly on proper detailing of the reinforcement in beamcolumn
joints and the old structures were found ductility deficient.
DSP materials are obtained by using high quantities of super
plasticizers and high volumes of micro silica. In the case of High
Performance Densified Small Particle Concrete (HPDSPC), since
concrete is dense even at the micro-structure level, tensile strain
would be much higher than that of the conventional SFRC, SIFCON
& SIMCON. This in turn will improve cracking behaviour, ductility
and energy absorption capacity of composites in addition to
durability. The fine fibers used in our mix are 0.3mm diameter and 10
mm which can be easily placed with high percentage. These fibers
easily transfer stresses and act as a composite concrete unit to take up
extremely high loads with high compressive strength. HPDSPC
placed in the beam column joints helps in safety of human life due to
prolonged failure.
Abstract: When high strength reinforced concrete is exposed to
high temperature due to a fire, deteriorations occur such as loss in
strength and elastic modulus, cracking and spalling of the concrete.
Therefore, it is important to understand risk of structural safety in
building structures by studying structural behaviors and rehabilitation
of fire damaged high strength concrete structures. This paper aims at
investigating rehabilitation effect on fire damaged high strength
concrete beams using experimental and analytical methods. In the
experiments, flexural specimens with high strength concrete are
exposed to high temperatures according to ISO 834 standard time
temperature curve. From four-point loading test, results show that
maximum loads of the rehabilitated beams are similar to or higher than
those of the non-fire damaged RC beam. In addition, structural
analyses are performed using ABAQUS 6.10-3 with same conditions
as experiments to provide accurate predictions on structural and
mechanical behaviors of rehabilitated RC beams. The parameters are
the fire cover thickness and strengths of repairing mortar. Analytical
results show good rehabilitation effects, when the results predicted
from the rehabilitated models are compared to structural behaviors of
the non-damaged RC beams. In this study, fire damaged high strength concrete beams are
rehabilitated using polymeric cement mortar. The predictions from the
finite element (FE) models show good agreements with the
experimental results and the modeling approaches can be used to
investigate applicability of various rehabilitation methods for further
study.
Abstract: Nowadays, energy dissipation devices are commonly
used in structures. High rate of energy absorption during earthquakes
is the benefit of using such devices, which results in damage
reduction of structural elements, specifically columns. The hysteretic
damping capacity of energy dissipation devices is the key point that it
may adversely make analysis and design process complicated. This
effect may be generally represented by Equivalent Viscous Damping
(EVD). The equivalent viscous damping might be obtained from the
expected hysteretic behavior regarding to the design or maximum
considered displacement of a structure. In this paper, the hysteretic
damping coefficient of a steel Moment Resisting Frame (MRF),
which its performance is enhanced by a Buckling Restrained Brace
(BRB) system has been evaluated. Having foresight of damping
fraction between BRB and MRF is inevitable for seismic design
procedures like Direct Displacement-Based Design (DDBD) method.
This paper presents an approach to calculate the damping fraction for
such systems by carrying out the dynamic nonlinear time history
analysis (NTHA) under harmonic loading, which is tuned to the
natural system frequency. Two MRF structures, one equipped with
BRB and the other without BRB are simultaneously studied.
Extensive analysis shows that proportion of each system damping
fraction may be calculated by its shear story portion. In this way,
contribution of each BRB in the floors and their general contribution
in the structural performance may be clearly recognized, in advance.
Abstract: This paper presents the influence of the vertical
seismic component on the non-linear dynamics analysis of three
different structures. The subject structures were analyzed and
designed according to recent codes. This paper considers three types
of buildings: 5-, 10-, and 15-story buildings. The non-linear dynamics
analysis of the structures with assuming elastic-perfectly-plastic
behavior was performed using RAM PERFORM-3D software; the
horizontal component was taken into consideration with and without
the incorporation of the corresponding vertical component. Dynamic
responses obtained for the horizontal component acting alone were
compared with those obtained from the simultaneous application of
both seismic components. The results show that the effect of the
vertical component of ground motion may increase the axial load
significantly in the interior columns and, consequently, the stories.
The plastic mechanisms would be changed. The P-Delta effect is
expected to increase. The punching base plate shear of the columns
should be considered. Moreover, the vertical component increases the
input energy when the structures exhibit inelastic behavior and are
taller.
Abstract: Fiber Reinforced Polymer (FRP) is a composite material with exceptional properties that are capable to replace conventional steel reinforcement in reinforced and pre-stressed concrete structures. However, the main obstacle for their wide use in pre-stressed concrete application is the anchorage system. Due to the weakness of FRP in the transverse direction, the pre-stressing capacity of FRP bars are limited. This paper investigates the modification of the conventional wedge anchorage system to be used for stressing of FRP bars in pre-stressed applications. Epoxy adhesive material with glass FRP (GFRP) bars and conventional steel wedge were used in this paper. The GFRP bars are encased with epoxy at the anchor zone and the wedge system was used in pull-out test. The results showed a loading capacity of 47.6 kN which is 69% of the bar ultimate capacity. Additionally, nylon wedge was made with the same dimensions of the steel wedge and tested for GFRP bars without epoxy layer. The nylon wedge showed a loading capacity of 19.7 kN which is only 28.5% of the ultimate bar capacity.
Abstract: Investigating the dynamic responses of high rise
structures under the effect of siesmic ground motion is extremely
important for the proper analysis and design of multitoried structures.
Since the presence of infilled walls strongly influences the behaviour
of frame systems in multistoried buildings, there is an increased need
for developing guidelines for the analysis and design of infilled
frames under the effect of dynamic loads for safe and proper design
of buildings. In this manuscript, we evaluate the natural frequencies
and natural periods of single bay single storey frames considering the
effect of infill walls by using the Eigen value analysis and validating
with SAP 2000 (free vibration analysis). Various parameters obtained
from the diagonal strut model followed for the free vibration analysis
is then compared with the Finite Element model, where infill is
modeled as shell elements (four noded). We also evaluated the effect
of various parameters on the natural periods of vibration obtained by
free vibration analysis in SAP 2000 comparing them with those
obtained by the empirical expressions presented in I.S. 1893(Part I)-
2002.