Abstract: Change in impedance of an encircling coil is obtained
in the present paper for the case where the electric conductivity and
magnetic permeability of a metal cylindrical tube depend on the
radial coordinate. The system of equations for the vector potential is
solved by means of the Fourier cosine transform. The solution is
expressed in terms of improper integral containing modified Bessel
functions of complex order.
Abstract: Large full frequency band gaps of surface and bulk
acoustic waves in two-dimensional phononic band structures with
hollow cylinders are addressed in this paper. It is well-known that
absolute frequency band gaps are difficultly obtained in a band
structure consisted of low-acoustic-impedance cylinders in
high-acoustic-impedance host materials such as PMMA/Ni band
structures. Phononic band structures with hollow cylinders are
analyzed and discussed to obtain large full frequency band gaps not
only for bulk modes but also for surface modes. The tendency of
absolute frequency band gaps of surface and bulk acoustic waves is
also addressed by changing the inner radius of hollow cylinders in this
paper. The technique and this kind of band structure are useful for
tuning the frequency band gaps and the design of acoustic waveguides.
Abstract: Powerline Communications –PLC– as an alternative
method for broadband networking, has the advantage of transmitting
over channels already used for electrical distribution or even
transmission. But these channels have been not designed with usual
wired channels requirements for broadband applications such as
stable impedance or known attenuation, and the network have to
reject noises caused by electrical appliances that share the same
channel. Noise control standards are difficult to complain or simply
do not exist on Latin-American environments. This paper analyzes
PLC throughput for home connectivity by probing noisy channel
scenarios in a PLC network and the statistical results are shown.
Abstract: The distance protection mainly the impedance relay which is considered as the main protection for transmission lines can be subjected to impedance measurement error which is, mainly, due to the fault resistance and to the power fluctuation. Thus, the impedance relay may not operate for a short circuit at the far end of the protected line (case of the under reach) or operates for a fault beyond its protected zone (case of overreach). In this paper, an approach to fault detection by a distance protection, which distinguishes between the faulty conditions and the effect of overload operation mode, has been developed. This approach is based on the symmetrical components; mainly the negative sequence, and it is taking into account both the effect of fault resistance and the overload situation which both have an effect upon the reliability of the protection in terms of dependability for the former and security for the latter.
Abstract: Regarding previous research studies it was concluded
that thin-walled fiber-cement composites are able to conduct electric
current under specific conditions. This property is ensured by using
of various kinds of carbon materials. Though carbon fibers are less
conductive than metal fibers, composites with carbon fibers were
evaluated as better current conductors than the composites with metal
fibers. The level of electric conductivity is monitored by the means of
impedance measurement of designed samples. These composites
could be used for a range of applications such as heating of
trafficable surfaces or shielding of electro-magnetic fields.
The aim of the present research was to design an element with the
ability to monitor internal processes in building structures and
prevent them from collapsing. As a typical element for laboratory
testing there was chosen a concrete column, which was repeatedly
subjected to load by simple pressure with continual monitoring of
changes in electrical properties.
Abstract: Lately, an interest has grown greatly in the usages of
RFID in an un-presidential applications. It is shown in the adaptation
of major software companies such as Microsoft, IBM, and Oracle
the RFID capabilities in their major software products. For example
Microsoft SharePoints 2010 workflow is now fully compatible with
RFID platform. In addition, Microsoft BizTalk server is also capable
of all RFID sensors data acquisition. This will lead to applications
that required high bit rate, long range and a multimedia content in
nature. Higher frequencies of operation have been designated for
RFID tags, among them are the 2.45 and 5.8 GHz. The higher the
frequency means higher range, and higher bit rate, but the drawback
is the greater cost. In this paper we present a single layer, low
profile patch antenna operates at 5.8 GHz with pure resistive input
impedance of 50 and close to directive radiation. Also, we propose
a modification to the design in order to improve the operation band
width from 8.7 to 13.8
Abstract: An array of piezoelectric micro actuators can be used
for radiation of an ultrasonic carrier signal modulated in amplitude
with an acoustic signal, which yields audio frequency applications as
the air acts as a self-demodulating medium. This application is
known as the parametric array. We propose a parametric array with
array elements based on existing piezoelectric micro ultrasonic
transducer (pMUT) design techniques. In order to reach enough
acoustic output power at a desired operating frequency, a proper ratio
between number of array elements and array size needs to be used,
with an array total area of the order of one cm square. The
transducers presented are characterized via impedance, admittance,
noise figure, transducer gain and frequency responses.
Abstract: To determine the presence and location of faults in a transmission by the adaptation of protective distance relay based on the measurement of fixed settings as line impedance is achieved by several different techniques. Moreover, a fast, accurate and robust technique for real-time purposes is required for the modern power systems. The appliance of radial basis function neural network in transmission line protection is demonstrated in this paper. The method applies the power system via voltage and current signals to learn the hidden relationship presented in the input patterns. It is experiential that the proposed technique is competent to identify the particular fault direction more speedily. System simulations studied show that the proposed approach is able to distinguish the direction of a fault on a transmission line swiftly and correctly, therefore suitable for the real-time purposes.
Abstract: We demonstrate a nonfaradaic electrochemical impedance spectroscopy measurement of biochemically modified gold plated electrodes using a two-electrode system. The absence of any redox indicator in the impedance measurements provide more precise and accurate characterization of the measured bioanalyte at molecular resolution. An equivalent electrical circuit of the electrodeelectrolyte interface was deduced from the observed impedance data of saline solution at low and high concentrations. The detection of biomolecular interactions was fundamentally correlated to electrical double-layer variation at modified interface. The investigations were done using 20mer deoxyribonucleic acid (DNA) strands without any label. Surface modification was performed by creating mixed monolayer of the thiol-modified single-stranded DNA and a spacer thiol (mercaptohexanol) by a two-step self-assembly method. The results clearly distinguish between the noncomplementary and complementary hybridization of DNA, at low frequency region below several hundreds Hertz.
Abstract: The two significant overvoltages in power system,
switching overvoltage and lightning overvoltage, are investigated in
this paper. Firstly, the effect of various power system parameters on
Line Energization overvoltages is evaluated by simulation in ATP.
The dominant parameters include line parameters; short-circuit
impedance and circuit breaker parameters. Solutions to reduce
switching overvoltages are reviewed and controlled closing using
switchsync controllers is proposed as proper method.
This paper also investigates lightning overvoltages in the
overhead-cable transition. Simulations are performed in
PSCAD/EMTDC. Surge arresters are applied in both ends of cable to
fulfill the insulation coordination. The maximum amplitude of
overvoltages inside the cable is surveyed which should be of great
concerns in insulation coordination studies.
Abstract: Present wireless communication demands compact and intelligent devices with multitasking capabilities at affordable cost. The focus in the presented paper is on a dual band antenna for wireless communication with the capability of operating at two frequency bands with same structure. Two resonance frequencies are observed with the second operation band at 4.2GHz approximately three times the first resonance frequency at 1.5GHz. Structure is simple loop of microstrip line with characteristic impedance 50 ohms. The proposed antenna is designed using defective ground structure (DGS) and shows the nearly one third reductions in size as compared to without DGS. This antenna was simulated on electromagnetic (EM) simulation software and fabricated using microwave integrated circuit technique on RT-Duroid dielectric substrate (εr= 2.22) of thickness (H=15 mils). The designed antenna was tested on automatic network analyzer and shows the good agreement with simulated results. The proposed structure is modeled into an equivalent electrical circuit and simulated on circuit simulator. Subsequently, theoretical analysis was carried out and simulated. The simulated, measured, equivalent circuit response, and theoretical results shows good resemblance. The bands of operation draw many potential applications in today’s wireless communication.
Abstract: Nuclear matrix protein 22 (NMP22) is a FDA approved
biomarker for bladder cancer. The objective of this study is to develop
a simple NMP22 immumosensor (NMP22-IMS) for accurate
measurement of NMP22. The NMP22-IMS was constructed with
NMP22 antibody immobilized on screen-printed carbon electrodes.
The construction procedures and antibody immobilization are simple.
Results showed that the NMP22-IMS has an excellent (r2³0.95)
response range (20 – 100 ng/mL). In conclusion, a simple and reliable
NMP22-IMS was developed, capable of precisely determining urine
NMP22 level.
Abstract: In this study, Li4SiO4 powder was successfully
synthesized via sol gel method followed by drying at 150oC. Lithium
oxide, Li2O and silicon oxide, SiO2 were used as the starting
materials with citric acid as the chelating agent. The obtained powder
was then sintered at various temperatures. Crystallographic phase
analysis, morphology and ionic conductivity were investigated
systematically employing X-ray diffraction, Fourier Transform
Infrared, Scanning Electron Microscopy and AC impedance
spectroscopy. XRD result showed the formation of pure monoclinic
Li4SiO4 crystal structure with lattice parameters a = 5.140 Å, b =
6.094 Å, c = 5.293 Å, β = 90o in the sample sintered at 750oC. This
observation was confirmed by FTIR analysis. The bulk conductivity
of this sample at room temperature was 3.35 × 10-6 S cm-1 and the
highest bulk conductivity of 1.16 × 10-4 S cm-1 was obtained at
100°C. The results indicated that, the Li4SiO4 compound has
potential to be used as host for LISICON structured solid electrolyte
for low temperature application.
Abstract: This paper will discuss about an active power generator scheduling method in order to increase the limit level of steady state systems. Some power generator optimization methods such as Langrange, PLN (Indonesian electricity company) Operation, and the proposed Z-Thevenin-based method will be studied and compared in respect of their steady state aspects. A method proposed in this paper is built upon the thevenin equivalent impedance values between each load respected to each generator. The steady state stability index obtained with the REI DIMO method. This research will review the 500kV-Jawa-Bali interconnection system. The simulation results show that the proposed method has the highest limit level of steady state stability compared to other optimization techniques such as Lagrange, and PLN operation. Thus, the proposed method can be used to create the steady state stability limit of the system especially in the peak load condition.
Abstract: As known, the guard wires of overhead high voltage
are usually grounded through the grounding systems of support and
of the terminal stations. They do affect the zero sequence impedance
value of the line, Z0, which is generally, calculated assuming that the
wires guard are at ground potential. In this way it is not considered
the effect of the resistances of earth of supports and stations. In this
work is formed a formula for the calculation of Z0 which takes
account of said resistances. Is also proposed a method of calculating
the impedance zero sequence overhead lines in which, in various
sections or spans, the guard wires are connected to the supports, or
isolated from them, or are absent. Parametric analysis is given for
lines 220 kV and 400 kV, which shows the extent of the errors made
with traditional methods of calculation.
Abstract: Arenga pinnata is an abundantly natural fiber that can be used for sound proof material. However, the scientific data of acoustics properties of Arenga pinnata was not available yet. In this study the sound absorption of pure arenga pinnata was measured. The thickness of Arenga pinnata was varied in 10 mm, 20 mm, 30mm, and 40mm. This work was carried out to investigate the potential of using Arenga pinnata fiber as raw material for sound absorbing material. Impedance Tube Method was used to measure sound absorption coefficient (α). The Measurements was done in accordance with ASTM E1050-98, that is the standard test method for impedance and absorption of acoustical materials using a tube, two microphones and a digital frequency analysis system . The results showed that sound absorption coefficients of Arenga pinnata were good from 2000 Hz to 5000 Hz within the range of 0.75 – 0.90. The optimum sound absorption coefficient was obtained from the thickness of 40 mm. These results indicated that Arenga pinnata fiber is promising to be used as raw material of sound absorbing material with low cost, light, and biodegradable.
Abstract: This paper proposes the method combining artificial
neural network (ANN) with particle swarm optimization (PSO) to
implement the maximum power point tracking (MPPT) by controlling
the rotor speed of the wind generator. First, the measurements of wind
speed, rotor speed of wind power generator and output power of wind
power generator are applied to train artificial neural network and to
estimate the wind speed. Second, the method mentioned above is
applied to estimate and control the optimal rotor speed of the wind
turbine so as to output the maximum power. Finally, the result reveals
that the control system discussed in this paper extracts the maximum
output power of wind generator within the short duration even in the
conditions of wind speed and load impedance variation.
Abstract: A new current-mode multifunction filter using minimum number of passive elements is proposed. The proposed filter has single-input and four high-impedance outputs. It uses four passive elements (two capacitors and two resistors) and four dual output second generation current conveyors. Each output provides a different filter response, namely, low-pass, high-pass, band-pass and band-reject. The sensitivity analysis is also carried out on both ideal and non-ideal filter configurations. The validity of the proposed filter is verified through PSPICE simulations.
Abstract: The intent of this essay is to evaluate the effectiveness
of surge suppressor aimed at power supply used for automation
devices in power distribution system which is consist of MOV and
T type low-pass filter. Books, journal articles and e-sources related
to surge protection of power supply used for automation devices in
power distribution system were consulted, and the useful information
was organized, analyzed and developed into five parts: characteristics
of surge wave, protection against surge wave, impedance characteristics
of target, using Matlab to simulate circuit response after
5kV,1.2/50s surge wave and suggestions for surge protection. The
results indicate that various types of load situation have great impact
on the effectiveness of surge protective device. Therefore, type and
parameters of surge protective device need to be carefully selected,
and load matching is also vital to be concerned.
Abstract: The biomarker for colorectal cancer (CRC) is CEACAM-6 antigen (C6AG). Therefore, this study aims to develop a novel, simple and low-cost CEACAM-6 antigen immumosensor (C6AG-IMS), based on electrical impedance measurement, for precise determination of C6AG. A low-cost screen-printed graphite electrode was constructed and used as the sensor, with CEACAM-6 antibody (C6AB) immobilized on it. The procedures of sensor fabrication and antibody immobilization are simple and low-cost. Measurement of the electrical impedance at a definite frequency ranges (0.43 – 1.26 MHz) showed that the C6AG-IMS has an excellent linear (r2>0.9) response range (8.125 – 65 pg/mL), covering the normal physiological and pathological ranges of blood C6AG levels. Also, the C6AG-IMS has excellent reliability and validity, with the intraclass correlation coefficient being 0.97. In conclusion, a novel, simple, low-cost and reliable C6AG-IMS was designed and developed, being able to accurately determine blood C6AG levels in the range of pathological and normal physiological regions. The C6AG-IMS can provide a point-of-care and immediate screening results to the user at home.