Abstract: This paper shows an experimental testing of a small
unit for combustion of solid fuels, such as charcoal and wood logs,
that can provide electricity. One of the concepts is that the unit does
not require qualified personnel for its operation. The unit itself is
composed of two main parts. The design requires a heat producing
stove and electricity producing thermoelectric generator. After the
construction the unit was tested and the results show that the
emission release is within the legislative requirements for emission
production and environmental protection. That qualifies such unit for
indoor application.
Abstract: The detection of moving objects from a video image
sequences is very important for object tracking, activity recognition,
and behavior understanding in video surveillance.
The most used approach for moving objects detection / tracking is
background subtraction algorithms. Many approaches have been
suggested for background subtraction. But, these are illumination
change sensitive and the solutions proposed to bypass this problem
are time consuming.
In this paper, we propose a robust yet computationally efficient
background subtraction approach and, mainly, focus on the ability to
detect moving objects on dynamic scenes, for possible applications in
complex and restricted access areas monitoring, where moving and
motionless persons must be reliably detected. It consists of three
main phases, establishing illumination changes invariance,
background/foreground modeling and morphological analysis for
noise removing.
We handle illumination changes using Contrast Limited Histogram
Equalization (CLAHE), which limits the intensity of each pixel to
user determined maximum. Thus, it mitigates the degradation due to
scene illumination changes and improves the visibility of the video
signal. Initially, the background and foreground images are extracted
from the video sequence. Then, the background and foreground
images are separately enhanced by applying CLAHE.
In order to form multi-modal backgrounds we model each channel
of a pixel as a mixture of K Gaussians (K=5) using Gaussian Mixture
Model (GMM). Finally, we post process the resulting binary
foreground mask using morphological erosion and dilation
transformations to remove possible noise.
For experimental test, we used a standard dataset to challenge the
efficiency and accuracy of the proposed method on a diverse set of
dynamic scenes.
Abstract: Poly vinyl acetate (PVA)-based titania (TiO2)–carbon
nanotube composite nanofibers (PVA-TCCNs) with various
PVA-to-solvent ratios and PVA-based TiO2 composite nanofibers
(PVA-TN) were synthesized using an electrospinning process,
followed by thermal treatment. The photocatalytic activities of these
nanofibers in the degradation of airborne monocyclic aromatics under
visible-light irradiation were examined. This study focuses on the
application of these photocatalysts to the degradation of the target
compounds at sub-part-per-million indoor air concentrations. The
characteristics of the photocatalysts were examined using scanning
electron microscopy, X-ray diffraction, ultraviolet-visible
spectroscopy, and Fourier-transform infrared spectroscopy. For all the
target compounds, the PVA-TCCNs showed photocatalytic
degradation efficiencies superior to those of the reference PVA-TN.
Specifically, the average photocatalytic degradation efficiencies for
benzene, toluene, ethyl benzene, and o-xylene (BTEX) obtained using
the PVA-TCCNs with a PVA-to-solvent ratio of 0.3 (PVA-TCCN-0.3)
were 11%, 59%, 89%, and 92%, respectively, whereas those observed
using PVA-TNs were 5%, 9%, 28%, and 32%, respectively.
PVA-TCCN-0.3 displayed the highest photocatalytic degradation
efficiency for BTEX, suggesting the presence of an optimal
PVA-to-solvent ratio for the synthesis of PVA-TCCNs. The average
photocatalytic efficiencies for BTEX decreased from 11% to 4%, 59%
to 18%, 89% to 37%, and 92% to 53%, respectively, when the flow
rate was increased from 1.0 to 4.0 L min1. In addition, the average
photocatalytic efficiencies for BTEX increased 11% to ~0%, 59% to
3%, 89% to 7%, and 92% to 13%, respectively, when the input
concentration increased from 0.1 to 1.0 ppm. The prepared
PVA-TCCNs were effective for the purification of airborne aromatics
at indoor concentration levels, particularly when the operating
conditions were optimized.
Abstract: This paper presents an adaptive thermal comfort
model study in the tropical country of Malaysia. A number of
researchers have been interested in applying the adaptive thermal
comfort model to different climates throughout the world, but so far
no study has been performed in Malaysia. For the use as a thermal
comfort model, which better applies to hot and humid climates, the
adaptive thermal comfort model was developed as part of this
research by using the collected results from a large field study in six
lecture halls with 178 students. The relationship between the
operative temperature and behavioral adaptations was determined. In
the developed adaptive model, the acceptable indoor neutral
temperatures lay within the range of 23.9-26.0C, with outdoor
temperatures ranging between 27.0-34.6C. The most comfortable
temperature for students in lecture hall was 25.7C.
Abstract: Auckland has a temperate climate with comfortable warm, dry summers and mild, wet winters. An Auckland school normally does not need air conditioning for cooling during the summer and only needs heating during the winter. The Auckland school building thermal design should more focus on winter thermal performance and indoor thermal comfort for energy efficiency. This field study of testing indoor and outdoor air temperatures, relative humidity and indoor surface temperatures of three classrooms with different envelopes were carried out in the Avondale College during the winter months in 2013. According to the field study data, this study is to compare and evaluate winter thermal performance and indoor thermal conditions of school buildings with different envelopes.
Abstract: The inspection of underneath vehicle system has been
given significant attention by governments after the threat of
terrorism become more prevalent. New technologies such as mobile
robots and computer vision are led to have more secure environment.
This paper proposed that a mobile robot like Aria robot can be used
to search and inspect the bombs under parking a lot vehicle. This
robot is using fuzzy logic and subsumption algorithms to control the
robot that movies underneath the vehicle. An OpenCV library and
laser Hokuyo are added to Aria robot to complete the experiment for
under vehicle inspection. This experiment was conducted at the
indoor environment to demonstrate the efficiency of our methods to
search objects and control the robot movements under vehicle. We
got excellent results not only by controlling the robot movement but
also inspecting object by the robot camera at same time. This success
allowed us to know the requirement to construct a new cost effective
robot with more functionality.
Abstract: Energy consumption and users’ satisfaction were
compared in three LEED certified office buildings in turkey and an
office building in Egypt. The field studies were conducted in summer
2012. The measured environmental parameters in the four buildings
were indoor air temperature, relative humidity, CO2 percentage and
light intensity. The traditional building is located in Smart Village in
Abu Rawash, Cairo, Egypt. The building was studied for 7 days
resulting in 84 responds. The three rated buildings are in Istanbul;
Turkey. A Platinum LEED certified office building is owned by
BASF and gained a platinum certificate for new construction and
major renovation. The building was studied for 3 days resulting in 13
responds. A Gold LEED certified office building is owned by BASF
and gained a gold certificate for new construction and major
renovation. The building was studied for 2 days resulting in 10
responds. A silver LEED certified office building is owned by
Unilever and gained a silver certificate for commercial interiors. The
building was studied for 7 days resulting in 84 responds.
The results showed that all buildings had no significant difference
regarding occupants’ satisfaction with the amount of lighting, noise
level, odor and access to the outdoor view. There was significant
difference between occupants’ satisfaction in LEED certified
buildings and the traditional building regarding the thermal
environment and the perception of the general environment (colors,
carpet and decoration. The findings suggest that careful design could
lead to a certified building that enhances the thermal environment and
the perception of the indoor environment leading to energy
consumption without scarifying occupants’ satisfaction.
Abstract: Supermarkets are the most electricity-intensive type of
commercial buildings. The unsuitable indoor environment of a
supermarket provided by abnormal HVAC operations incurs waste
energy consumption in refrigeration systems. This current study
briefly describes significantly solid backgrounds and proposes easyto-
use analysis terminology for investigating the impact of HVAC
operations on refrigeration power consumption using the field-test
data obtained from building automation system (BAS). With solid
backgrounds and prior knowledge, expected energy interactions
between HVAC and refrigeration systems are proposed through
Pearson’s correlation analysis (R value) by considering correlations
between equipment power consumption and dominantly independent
variables (driving force conditions).The R value can be conveniently
utilized to evaluate how strong relations between equipment
operations and driving force parameters are. The calculated R values
obtained from field data are compared to expected ranges of R values
computed by energy interaction methodology. The comparisons can
separate the operational conditions of equipment into faulty and
normal conditions. This analysis can simply investigate the condition
of equipment operations or building sensors because equipment could
be abnormal conditions due to routine operations or faulty
commissioning processes in field tests. With systematically solid and
easy-to-use backgrounds of interactions provided in the present
article, the procedures can be utilized as a tool to evaluate the proper
commissioning and routine operations of HVAC and refrigeration
systems to detect simple faults (e.g. sensors and driving force
environment of refrigeration systems and equipment set-point) and
optimize power consumption in supermarket buildings. Moreover,
the analysis will be used to further study the FDD research for
supermarkets in future.
Abstract: Heating, cooling and lighting appliances in buildings
account for more than one third of the world’s primary energy
demand. Therefore, main components of the building heating systems
play an essential role in terms of energy consumption. In this context,
efficient energy and exergy utilization in HVAC-R systems has been
very essential, especially in developing energy policies towards
increasing efficiencies. The main objective of the present study is to
assess the performance of a family house with a volume of 326.7 m3
and a net floor area of 121 m2, located in the city of Izmir, Turkey in
terms of energetic, exergetic and sustainability aspects. The indoor
and exterior air temperatures are taken as 20°C and 1°C, respectively.
In the analysis and assessment, various metrics (indices or indicators)
such as exergetic efficiency, exergy flexibility ratio and sustainability
index are utilized. Two heating options (Case 1: condensing boiler
and Case 2: air heat pump) are considered for comparison purposes.
The total heat loss rate of the family house is determined to be
3770.72 W. The overall energy efficiencies of the studied cases are
calculated to be 49.4% for Case 1 and 54.7% for Case 2. The overall
exergy efficiencies, the flexibility factor and the sustainability index
of Cases 1 and 2 are computed to be around 3.3%, 0.17 and 1.034,
respectively.
Abstract: Sustainable tall buildings that provide comfortable,
healthy and efficient indoor environments are clearly desirable as the
densification of living and working space for the world’s increasing
population proceeds. For environmental concerns, these buildings
must also be energy efficient. One component of these tasks is the
provision of indoor air quality and thermal comfort, which can be
enhanced with natural ventilation by the supply of fresh air. Working
spaces can only be naturally ventilated with connections to the
outdoors utilizing operable windows, double facades, ventilation
stacks, balconies, patios, terraces and skygardens. Large amounts of
fresh air can be provided to the indoor spaces without mechanical
air-conditioning systems, which are widely employed in
contemporary tall buildings.
This paper tends to present the concept of natural ventilation for
sustainable tall office buildings in order to achieve healthy and
comfortable working spaces, as well as energy efficient
environments. Initially the historical evolution of ventilation
strategies for tall buildings is presented, beginning with natural
ventilation and continuing with the introduction of mechanical airconditioning
systems. Then the emergence of natural ventilation due
to the health and environmental concerns in tall buildings is handled,
and the strategies for implementing this strategy are revealed. In the
next section, a number of case studies that utilize this strategy are
investigated. Finally, how tall office buildings can benefit from this
strategy is discussed.
Abstract: Lately, with the increasing number of location-based applications, demand for highly accurate and reliable indoor localization became urgent. This is a challenging problem, due to the measurement variance which is the consequence of various factors like obstacles, equipment properties and environmental changes in complex nature of indoor environments. In this paper we propose low-cost custom-setup infrastructure solution and localization algorithm based on the Weighted Centroid Localization (WCL) method. Localization accuracy is increased by several enhancements: calibration of RSSI values gained from wireless nodes, repetitive measurements of RSSI to exclude deviating values from the position estimation, and by considering orientation of the device according to the wireless nodes. We conducted several experiments to evaluate the proposed algorithm. High accuracy of ~1m was achieved.
Abstract: In this paper, we propose an optimization technique
that can be used to optimize the placements of reference nodes and
improve the location determination performance for the multi-floor
building. The proposed technique is based on Simulated Annealing
algorithm (SA) and is called MSMR-M. The performance study in
this work is based on simulation. We compare other node-placement
techniques found in the literature with the optimal node-placement
solutions obtained from our optimization. The results show that using
the optimal node-placement obtained by our proposed technique can
improve the positioning error distances up to 20% better than those of
the other techniques. The proposed technique can provide an average
error distance within 1.42 meters.
Abstract: Indoor wireless localization systems have played an
important role to enhance context-aware services. Determining the
position of mobile objects in complex indoor environments, such as
those in multi-floor buildings, is very challenging problems. This
paper presents an effective floor estimation algorithm, which can
accurately determine the floor where mobile objects located. The
proposed algorithm is based on the confidence interval of the
summation of online Received Signal Strength (RSS) obtained from
the IEEE 802.15.4 Wireless Sensor Networks (WSN).We compare
the performance of the proposed algorithm with those of other floor
estimation algorithms in literature by conducting a real
implementation of WSN in our facility. The experimental results and
analysis showed that the proposed floor estimation algorithm
outperformed the other algorithms and provided highest percentage
of floor accuracy up to 100% with 95-percent confidence interval.
Abstract: The paper presents actual benefits and drawbacks of a multidirectional autonomous hovercraft conceived with limited resources and designed for indoor exploration. Recent developments in the field have led to the apparition of very powerful automotive systems capable of very high calculation and exploration in complex unknown environments. They usually propose very complex algorithms, high precision/cost sensors and sometimes have heavy calculation consumption with complex data fusion. These systems are usually powerful but have a certain price, and the benefits may not be worth the cost, especially considering their hardware limitations and their power consumption. The present approach is to build a compromise between cost, power consumption and results preciseness.
Abstract: The objectives of the present study were to estimate the microbial-N flow to the small intestine and to predict the digestible organic matter intake (DOMI) in grazing Karayaka sheep based on urinary excretion of purine derivatives (xanthine, hypoxanthine, uric acid, and allantoin) by the use of spot urine sampling under field conditions. In the trial, 10 Karayaka sheep from 2 to 3 years of age were used. The animals were grazed in a pasture for ten months and fed with concentrate and vetch plus oat hay for the other two months (January and February) indoors. Highly significant linear and cubic relationships (P
Abstract: A one-dimensional mathematical model was developed in order to analyze and optimize the latent heat storage wall. The governing equations for energy transport were developed by using the enthalpy method and discretized with volume control scheme. The resulting algebraic equations were next solved iteratively by using TDMA algorithm. A series of numerical investigations were conducted in order to examine the effects of the thickness of the PCM layer on the thermal behavior of the proposed heating system. Results are obtained for thermal gain and temperature fluctuation. The charging discharging process was also presented and analyzed.
Abstract: The paper represents the dependence of ammonia concentration on microclimate parameters and photocopying shop circulation. The concentration of ammonia was determined during 8-hours working time over five days including three sampling points of a photocopying shop in Novi Sad, Serbia. The obtained results pointed out that the room temperature possesses the highest impact on ammonia release. The obtained ammonia concentration was in the range of 1.53 to 0.42ppm and decreased with the temperature decreasing from 24.6 to 20.7oC. As the detected concentrations were within the permissible levels of The Occupational Safety and Health Administration, The National Institute for Occupational Safety and The Health and Official Gazette of Republic of Serbia, in the range of 35 to 200ppm, there was no danger to the employee’s health in the photocopying shop.
Abstract: Climate considerations are essential dimensions in the assessment of thermal comfort and indoor environments inside Egyptian housing. The primary aim of this paper is to analyze the indoor environment of new housing in the new city of Assiut in the Southern Upper Egypt zone, in order to evaluate its thermal environment and determine the acceptable indoor operative temperatures. The psychrometric charts for ASHRAE Standard 55 and ACS used in this study would facilitate an overall representation of the climate in one of the hottest months in the summer season. This study helps to understand and deal with this problem and work on a passive cooling ventilation strategy in these contexts in future studies. The results that demonstrated the indoor temperature is too high, ranges between 31°C to 40°C in different natural ventilation strategies. This causes the indoor environment to be far from the optimum comfort operative temperature of ACS except when using air conditioners. Finally, this study is considered a base for developing a new system using natural ventilation with passive cooling strategies.
Abstract: In this paper, we present the simulation of the propagation characteristics of the picocellular propagation channel environment. The first aim has been to find a correct description of the environment for received wave.
The result of the first investigations is that the environment of the indoor wave significantly changes as we change the electric parameters of material constructions. A modified 3D ray tracing image method tool has been utilized for the coverage prediction. A detailed analysis of the dependence of the indoor wave on the wideband characteristics of the channel: root mean square (RMS) delay spread characteristics and Mean excess delay, is also investigated.
Abstract: This paper studied the CSS-based indoor localization system which is easy to implement, inexpensive to compose the systems, additionally CSS-based indoor localization system covers larger area than other system. However, this system has problem which is affected by reflected distance data. This problem in localization is caused by the multi-path effect. Error caused by multi-path is difficult to be corrected because the indoor environment cannot be described. In this paper, in order to solve the problem by multi-path, we have supplemented the localization system by using pattern matching method based on extended database. Thereby, this method improves precision of estimated. Also this method is verified by experiments in gymnasium. Database was constructed by 1m intervals, and 16 sample data were collected from random position inside the region of DB points. As a result, this paper shows higher accuracy than existing method through graph and table.