Abstract: Since MEMS gyro sensors measure not angle of rotation but angular rate, an estimator is designed to estimate the angles in many applications. Gyro and accelerometer are used to improve estimating accuracy of the angle. This paper presents a method of finding filter coefficients of the well-known estimator which is to get rotation angles from gyro and accelerometer data. In order to verify the performance of our method, the estimated angle is compared with the encoder output in a rotary pendulum system.
Abstract: The aged are faced with increasing risk for falls. The
aged have the easily fragile bones than others. When falls have
occurred, it is important to detect this emergency state because such
events often lead to more serious illness or even death. A
implementation of PDA system, for detection of emergency situation,
was developed using 3-axis accelerometer in this paper as follows.
The signals were acquired from the 3-axis accelerometer, and then
transmitted to the PDA through Bluetooth module. This system can
classify the human activity, and also detect the emergency state like
falls. When the fall occurs, the system generates the alarm on the
PDA. If a subject does not respond to the alarm, the system determines
whether the current situation is an emergency state or not, and then
sends some information to the emergency center in the case of urgent
situation. Three different studies were conducted on 12 experimental
subjects, with results indicating a good accuracy. The first study was
performed to detect the posture change of human daily activity. The
second study was performed to detect the correct direction of fall. The
third study was conducted to check the classification of the daily
physical activity. Each test was lasted at least 1 min. in third study.
The output of acceleration signal was compared and evaluated by
changing a various posture after attaching a 3-axis accelerometer
module on the chest. The newly developed system has some important
features such as portability, convenience and low cost. One of the
main advantages of this system is that it is available at home
healthcare environment. Another important feature lies in low cost to
manufacture device. The implemented system can detect the fall
accurately, so will be widely used in emergency situation.
Abstract: Falls are the primary cause of accidents in people over
the age of 65, and frequently lead to serious injuries. Since the early
detection of falls is an important step to alert and protect the aging
population, a variety of research on detecting falls was carried out
including the use of accelerators, gyroscopes and tilt sensors. In
exiting studies, falls were detected using an accelerometer with
errors. In this study, the proposed method for detecting falls was to
use two accelerometers to reject wrong falls detection. As falls are
accompanied by the acceleration of gravity and rotational motion, the
falls in this study were detected by using the z-axial acceleration
differences between two sites. The falls were detected by calculating
the difference between the analyses of accelerometers placed on two
different positions on the chest of the subject. The parameters of the
maximum difference of accelerations (diff_Z) and the integration of
accelerations in a defined region (Sum_diff_Z) were used to form the
fall detection algorithm. The falls and the activities of daily living
(ADL) could be distinguished by using the proposed parameters
without errors in spite of the impact and the change in the positions
of the accelerometers. By comparing each of the axial accelerations,
the directions of falls and the condition of the subject afterwards
could be determined.In this study, by using two accelerometers
without errors attached to two sites to detect falls, the usefulness of
the proposed fall detection algorithm parameters, diff_Z and
Sum_diff_Z, were confirmed.
Abstract: The effect of the rotational speed and axial torque on
the diagnostics of tapered rolling element bearing defects was
investigated. The accelerometer was mounted on the bearing housing
and connected to Sound and Vibration Analyzer (SVAN 958) and
was used to measure the accelerations from the bearing housing. The
data obtained from the bearing was processed to detect damage of the
bearing using statistical tools and the results were subsequently
analyzed to see if bearing damage had been captured. From this study
it can be seen that damage is more evident when the bearing is
loaded. Also, at the incipient stage of damage the crest factor and
kurtosis values are high but as time progresses the crest factors and
kurtosis values decrease whereas the peak and RMS values are low at
the incipient stage but increase with damage.
Abstract: This paper explores the opportunity of using tri-axial
wireless accelerometers for supervised monitoring of sports
movements. A motion analysis system for the upper extremities of
lawn bowlers in particular is developed. Accelerometers are placed
on parts of human body such as the chest to represent the shoulder
movements, the back to capture the trunk motion, back of the hand,
the wrist and one above the elbow, to capture arm movements. These
sensors placement are carefully designed in order to avoid restricting
bowler-s movements. Data is acquired from these sensors in soft-real
time using virtual instrumentation; the acquired data is then
conditioned and converted into required parameters for motion
regeneration. A user interface was also created to facilitate in the
acquisition of data, and broadcasting of commands to the wireless
accelerometers. All motion regeneration in this paper deals with the
motion of the human body segment in the X and Y direction, looking
into the motion of the anterior/ posterior and lateral directions
respectively.