Abstract: In very narrow pathways, the speed of sound propagation and the phase of sound waves change due to the air viscosity. We have developed a new finite element method (FEM) that includes the effects of air viscosity for modeling a narrow sound pathway. This method is developed as an extension of the existing FEM for porous sound-absorbing materials. The numerical calculation results for several three-dimensional slit models using the proposed FEM are validated against existing calculation methods.
Abstract: In this paper, by exploiting a single semiconductor
optical amplifier-Mach Zehnder Interferometer (SOA-MZI), an
integratable all-optical flip-flop (AOFF) is proposed. It is composed
of a SOA-MZI with a bidirectional coupler at the output. Output
signals of both bar and crossbar of the SOA-MZI is fed back to SOAs
located in the arms of the Mach-Zehnder Interferometer (MZI). The
injected photon-rates to the SOAs are modulated by feedback signals
in order to form optical flip-flop. According to numerical analysis,
Gaussian optical pulses with the energy of 15.2 fJ and 20 ps duration
with the full width at half-maximum criterion, can switch the states of
the SR-AOFF. Also simulation results show that the SR-AOFF has
the contrast ratio of 8.5 dB between two states with the transition
time of nearly 20 ps.
Abstract: This work deals with unsupervised image deblurring.
We present a new deblurring procedure on images provided by lowresolution
synthetic aperture radar (SAR) or simply by multimedia in
presence of multiplicative (speckle) or additive noise, respectively.
The method we propose is defined as a two-step process. First, we
use an original technique for noise reduction in wavelet domain.
Then, the learning of a Kohonen self-organizing map (SOM) is
performed directly on the denoised image to take out it the blur. This
technique has been successfully applied to real SAR images, and the
simulation results are presented to demonstrate the effectiveness of
the proposed algorithms.
Abstract: Wind farms (WFs) with high level of penetration are
being established in power systems worldwide more rapidly than
other renewable resources. The Independent System Operator (ISO),
as a policy maker, should propose appropriate places for WF
installation in order to maximize the benefits for the investors. There
is also a possibility of congestion relief using the new installation of
WFs which should be taken into account by the ISO when proposing
the locations for WF installation. In this context, efficient wind farm
(WF) placement method is proposed in order to reduce burdens on
congested lines. Since the wind speed is a random variable and load
forecasts also contain uncertainties, probabilistic approaches are used
for this type of study. AC probabilistic optimal power flow (P-OPF)
is formulated and solved using Monte Carlo Simulations (MCS). In
order to reduce computation time, point estimate methods (PEM) are
introduced as efficient alternative for time-demanding MCS.
Subsequently, WF optimal placement is determined using generation
shift distribution factors (GSDF) considering a new parameter
entitled, wind availability factor (WAF). In order to obtain more
realistic results, N-1 contingency analysis is employed to find the
optimal size of WF, by means of line outage distribution factors
(LODF). The IEEE 30-bus test system is used to show and compare
the accuracy of proposed methodology.
Abstract: This paper presents the results of a comprehensive
investigation of five blackouts that occurred on 28 August to 8
September 2011 due to bushing failures of the 132/33 kV, 125 MVA
transformers at JBB Ali Grid station. The investigation aims to
explore the root causes of the bushing failures and come up with
recommendations that help in rectifying the problem and avoiding the
reoccurrence of similar type of incidents. The incident reports about
the failed bushings and the SCADA reports at this grid station were
examined and analyzed. Moreover, comprehensive power quality
field measurements at ten 33/11 kV substations (S/Ss) in JBB Ali
area were conducted, and frequency scans were performed to verify
any harmonic resonance frequencies due to power factor correction
capacitors. Furthermore, the daily operations of the on-load tap
changers (OLTCs) of both the 125 MVA and 20 MVA transformers
at JBB Ali Grid station have been analyzed. The investigation
showed that the five bushing failures were due to a local problem, i.e.
internal degradation of the bushing insulation. This has been
confirmed by analyzing the time interval between successive OLTC
operations of the faulty grid transformers. It was also found that
monitoring the number of OLTC operations can help in predicting
bushing failure.
Abstract: This paper considers the problem of Null-Steering beamforming using Neural Network (NN) approach for antenna array system. Two cases are presented. First, unlike the other authors, the estimated Direction Of Arrivals (DOAs) are used for antenna array weights NN-based determination and the imprecise DOAs estimations are taken into account. Second, the blind null-steering beamforming is presented. In this case the antenna array outputs are presented at the input of the NN without DOAs estimation. The results of computer simulations will show much better relative mean error performances of the first NN approach compared to the NNbased blind beamforming.
Abstract: This paper describes the shape optimization of impeller
blades for a anti-heeling bidirectional axial flow pump used in ships.
In general, a bidirectional axial pump has an efficiency much lower
than the classical unidirectional pump because of the symmetry of the
blade type. In this paper, by focusing on a pump impeller, the shape of
blades is redesigned to reach a higher efficiency in a bidirectional axial
pump. The commercial code employed in this simulation is CFX v.13.
CFD result of pump torque, head, and hydraulic efficiency was
compared. The orthogonal array (OA) and analysis of variance
(ANOVA) techniques and surrogate model based optimization using
orthogonal polynomial, are employed to determine the main effects
and their optimal design variables. According to the optimal design,
we confirm an effective design variable in impeller blades and explain
the optimal solution, the usefulness for satisfying the constraints of
pump torque and head.
Abstract: In this paper, we propose the Modified Synchronous Detection (MSD) Method for determining the reference compensating currents of the shunt active power filter under non sinusoidal voltages conditions. For controlling the inverter switching we used the PI regulator. The numerical simulation results, using Power System Blockset Toolbox PSB of Matlab, from a complete structure, are presented and discussed.
Abstract: Serious games have proven to be a useful instrument
to engage learners and increase motivation. Nevertheless, a broadly
accepted, practical instructional design approach to serious games
does not exist. In this paper, we introduce the use of an instructional
design model that has not been applied to serious games yet, and has
some advantages compared to other design approaches. We present
the case of mechanics mechatronics education to illustrate the close
match with timing and role of knowledge and information that the
instructional design model prescribes and how this has been
translated to a rigidly structured game design. The structured
approach answers the learning needs of applicable knowledge within
the target group. It combines advantages of simulations with
strengths of entertainment games to foster learner-s motivation in the
best possible way. A prototype of the game will be evaluated along a
well-respected evaluation method within an advanced test setting
including test and control group.
Abstract: Traditional multivariate control charts assume that measurement from manufacturing processes follows a multivariate normal distribution. However, this assumption may not hold or may be difficult to verify because not all the measurement from manufacturing processes are normal distributed in practice. This study develops a new multivariate control chart for monitoring the processes with non-normal data. We propose a mechanism based on integrating the one-class classification method and the adaptive technique. The adaptive technique is used to improve the sensitivity to small shift on one-class classification in statistical process control. In addition, this design provides an easy way to allocate the value of type I error so it is easier to be implemented. Finally, the simulation study and the real data from industry are used to demonstrate the effectiveness of the propose control charts.
Abstract: This paper presents a new method of fault detection and isolation (FDI) for polymer electrolyte membrane (PEM) fuel cell (FC) dynamic systems under an open-loop scheme. This method uses a radial basis function (RBF) neural network to perform fault identification, classification and isolation. The novelty is that the RBF model of independent mode is used to predict the future outputs of the FC stack. One actuator fault, one component fault and three sensor faults have been introduced to the PEMFC systems experience faults between -7% to +10% of fault size in real-time operation. To validate the results, a benchmark model developed by Michigan University is used in the simulation to investigate the effect of these five faults. The developed independent RBF model is tested on MATLAB R2009a/Simulink environment. The simulation results confirm the effectiveness of the proposed method for FDI under an open-loop condition. By using this method, the RBF networks able to detect and isolate all five faults accordingly and accurately.
Abstract: In recent years the large scale use of the power electronic equipment has led to an increase of harmonics in the power system. The harmonics results into a poor power quality and have great adverse economical impact on the utilities and customers. Current harmonics are one of the most common power quality problems and are usually resolved by using shunt active filter (SHAF). The main objective of this work is to develop PI and Fuzzy logic controllers (FLC) to analyze the performance of Shunt Active Filter for mitigating current harmonics under balanced and unbalanced sinusoidal source voltage conditions for normal load and increased load. When the supply voltages are ideal (balanced), both PI and FLC are converging to the same compensation characteristics. However, the supply voltages are non-ideal (unbalanced), FLC offers outstanding results. Simulation results validate the superiority of FLC with triangular membership function over the PI controller.
Abstract: This paper proposes a novel solution for optimizing
the size and communication overhead of a distributed multiagent
system without compromising the performance. The proposed approach
addresses the challenges of scalability especially when the
multiagent system is large. A modified spectral clustering technique
is used to partition a large network into logically related clusters.
Agents are assigned to monitor dedicated clusters rather than monitor
each device or node. The proposed scalable multiagent system is
implemented using JADE (Java Agent Development Environment)
for a large power system. The performance of the proposed topologyindependent
decentralized multiagent system and the scalable multiagent
system is compared by comprehensively simulating different
fault scenarios. The time taken for reconfiguration, the overall computational
complexity, and the communication overhead incurred are
computed. The results of these simulations show that the proposed
scalable multiagent system uses fewer agents efficiently, makes faster
decisions to reconfigure when a fault occurs, and incurs significantly
less communication overhead.
Abstract: The present work demonstrates the design and simulation of a fuzzy control of an air conditioning system at different pressures. The first order Sugeno fuzzy inference system is utilized to model the system and create the controller. In addition, an estimation of the heat transfer rate and water mass flow rate injection into or withdraw from the air conditioning system is determined by the fuzzy IF-THEN rules. The approach starts by generating the input/output data. Then, the subtractive clustering algorithm along with least square estimation (LSE) generates the fuzzy rules that describe the relationship between input/output data. The fuzzy rules are tuned by Adaptive Neuro-Fuzzy Inference System (ANFIS). The results show that when the pressure increases the amount of water flow rate and heat transfer rate decrease within the lower ranges of inlet dry bulb temperatures. On the other hand, and as pressure increases the amount of water flow rate and heat transfer rate increases within the higher ranges of inlet dry bulb temperatures. The inflection in the pressure effect trend occurs at lower temperatures as the inlet air humidity increases.
Abstract: The draw solute separation process in Forward
Osmosis desalination was simulated in Aspen Plus chemical process
modeling software, to estimate the energy consumption and compare
it with other desalination processes, mainly the Reverse Osmosis
process which is currently most prevalent. The electrolytic chemistry
for the system was retrieved using the Elec – NRTL property method
in the Aspen Plus database. Electrical equivalent of energy required
in the Forward Osmosis desalination technique was estimated and
compared with the prevalent desalination techniques.
Abstract: In wireless sensor network (WSN) the use of mobile
sink has been attracting more attention in recent times. Mobile sinks
are more effective means of balancing load, reducing hotspot
problem and elongating network lifetime. The sensor nodes in WSN
have limited power supply, computational capability and storage and
therefore for continuous data delivery reliability becomes high
priority in these networks. In this paper, we propose a Reliable
Energy-efficient Data Dissemination (REDD) scheme for WSNs with
multiple mobile sinks. In this strategy, sink first determines the
location of source and then directly communicates with the source
using geographical forwarding. Every forwarding node (FN) creates a
local zone comprising some sensor nodes that can act as
representative of FN when it fails. Analytical and simulation study
reveals significant improvement in energy conservation and reliable
data delivery in comparison to existing schemes.
Abstract: This paper presents a new spread-spectrum
watermarking algorithm for digital images in discrete wavelet
transform (DWT) domain. The algorithm is applied for embedding
watermarks like patient identification /source identification or
doctors signature in binary image format into host digital
radiological image for potential telemedicine applications.
Performance of the algorithm is analysed by varying the gain factor,
subband decomposition levels, and size of watermark. Simulation
results show that the proposed method achieves higher watermarking
capacity.
Abstract: The neural network's performance can be measured by efficiency and accuracy. The major disadvantages of neural network approach are that the generalization capability of neural networks is often significantly low, and it may take a very long time to tune the weights in the net to generate an accurate model for a highly complex and nonlinear systems. This paper presents a novel Neuro-fuzzy architecture based on Extended Kalman filter. To test the performance and applicability of the proposed neuro-fuzzy model, simulation study of nonlinear complex dynamic system is carried out. The proposed method can be applied to an on-line incremental adaptive learning for the prediction of financial time series. A benchmark case studie is used to demonstrate that the proposed model is a superior neuro-fuzzy modeling technique.
Abstract: In the present study, the pressure drop and laminar convection heat transfer characteristics of nanofluids in microchannel heat sink with square duct are numerically investigated. The water based nanofluids created with Al2O3 and CuO particles in four different volume fractions of 0%, 0.5%, 1%, 1.5% and 2% are used to analyze their effects on heat transfer and the pressure drop. Under the laminar, steady-state flow conditions, the finite volume method is used to solve the governing equations of heat transfer. Mixture Model is considered to simulate the nanofluid flow. For verification of used numerical method, the results obtained from numerical calculations were compared with the results in literature for both pure water and the nanofluids in different volume fractions. The distributions of the particles in base fluid are assumed to be uniform. The results are evaluated in terms of Nusselt number, the pressure drop and heat transfer enhancement. Analysis shows that the nanofluids enhance heat transfer while the Reynolds number and the volume fractions are increasing. The best overall enhancement was obtained at φ=%2 and Re=100 for CuO-water nanofluid.
Abstract: A geothermal power plant multiple simulator for
operators training is presented. The simulator is designed to be
installed in a wireless local area network and has a capacity to train
one to six operators simultaneously, each one with an independent
simulation session. The sessions must be supervised only by one
instructor. The main parts of this multiple simulator are: instructor
and operator-s stations. On the instructor station, the instructor
controls the simulation sessions, establishes training exercises and
supervises each power plant operator in individual way. This station
is hosted in a Main Personal Computer (NS) and its main functions
are: to set initial conditions, snapshots, malfunctions or faults,
monitoring trends, and process and soft-panel diagrams. On the other
hand the operators carry out their actions over the power plant
simulated on the operator-s stations; each one is also hosted in a PC.
The main software of instructor and operator-s stations are executed
on the same NS and displayed in PCs through graphical Interactive
Process Diagrams (IDP). The geothermal multiple simulator has been
installed in the Geothermal Simulation Training Center (GSTC) of
the Comisi├│n Federal de Electricidad, (Federal Commission of
Electricity, CFE), Mexico, and is being utilized as a part of the
training courses for geothermal power plant operators.