Abstract: The aesthetic qualities and the versatility of reinforced
concrete have made it a popular choice for many architects and
structural engineers. Therefore, the exploration of natural materials
such as gravels and sands as well as lime-stone for cement production
is increasing to produce a concrete material. The exploration must
affect to the environment. Therefore, the using of the concrete
materials should be as efficient as possible. According to its natural
behavior of the concrete material, it is strong in compression and weak
in tension. Therefore the contribution of the tensile stresses of the
concrete to the flexural capacity of the beams is neglected. However,
removing of concrete on tension zone affects to the decreasing of
flexural capacity. Introduce the strut action of truss structures may an
alternative to solve the decreasing of flexural capacity. A series of
specimens were prepared to clarify the effect of the truss structures in
the concrete beams without concrete on the tension zone. Results
indicated that the truss system is necessary for the external reinforced
concrete beams. The truss system of concrete beam without concrete
on tension zone (BR) could develop almost same capacity to the
normal beam (BN). It can be observed also that specimens BR has
lower number of cracks than specimen BN. This may be caused by the
fact that there was no bonding effect on the tensile reinforcement on
specimen BR to distribute the cracks.
Abstract: The aim of this work is to use an environmental, cheap; organic non-traditional admixture to improve the structural behavior of sustainable reinforced concrete beams contains different ratios of recycled concrete aggregate. The used admixture prepared by using wastes from vegetable oil industry. Under and over reinforced concrete beams made from natural aggregate and different ratios of recycled concrete aggregate were tested under static load until failure. Eight beams were tested to investigate the performance and mechanism effect of admixture on improving deformation characteristics, modulus of elasticity and toughness of tested beams. Test results show efficiency of organic admixture on improving flexural behavior of beams contains 20% recycled concrete aggregate more over the other ratios.
Abstract: This paper presents the Literature Review of carbon fiber reinforced polymer (CFRP) strips to reinforced concrete (RC) as a strengthening solution for T-beams. Although a great deal of research has been carried out on Rectangular beams strengthened with Fibre-Reinforced Polymer composites (FRP), Fiber reinforced polymer (FRP) composites have been increasingly studied for their application in the flexural or shear strengthening of reinforced concrete (RC) members. A detailed discussion of the shearstrengthening repair with FRP is undertaken. This paper will be limited to research of CFRP material externally bonded to the tensile face of concrete beams. In particular, research studying the effect of externally applied CFRP materials on the shear performance of reinforced concrete beams will be reported.
Abstract: In the modern construction practices, industrial wastes
or by-products are largely used as raw materials in cement and
concrete. These impart many benefits to the environment and bringabout
an economic impact because the cost of waste disposal is
constantly increasing due to strict environmental regulations. It was
reported in literature that the leakage of oil onto concrete element in
older cement grinding unit resulted in concrete with greater resistance
to freezing and thawing. This effect was thought to be similar to
adding an air-entraining chemical admixture to concrete. This paper
presents an investigation on the load deflection behaviour and crack
patterns of reinforced concrete (RC) beams subjected to four point
loading. Ten 120x260x1900 mm beams were cast with 100%
ordinary Portland cement (OPC) concrete, 20% fly ash (FA) and 20%
rice husk ash (RHA) blended cement concrete. 0.15% dosage of
admixtures (used engine oil, new engine oil, and superplasticizer)
was used throughout the experiment. Results show that OPC and
OPC/RHA RC beams containing used engine oil and superplasticizer
exhibit higher capacity, 18-26% than their corresponding control
mix.
Abstract: Reinforced concrete has good durability and excellent structural performance. But there are cases of early deterioration due to a number of factors, one prominent factor being corrosion of steel reinforcement. The process of corrosion sets in due to ingress of moisture, oxygen and other ingredients into the body of concrete, which is unsound, permeable and absorbent. Cracks due to structural and other causes such as creep, shrinkage, etc also allow ingress of moisture and other harmful ingredients and thus accelerate the rate of corrosion. There are several interactive factors both external and internal, which lead to corrosion of reinforcement and ultimately failure of structures. Suitable addition of mineral admixture like silica fume (SF) in concrete improves the strength and durability of concrete due to considerable improvement in the microstructure of concrete composites, especially at the transition zone. Secondary reinforcement in the form of fibre is added to concrete, which provides three dimensional random reinforcement in the entire mass of concrete. Reinforced concrete beams of size 0.1 m X 0.15 m and length 1m have been cast using M 35 grade of concrete. The beams after curing process were subjected to corrosion process by impressing an external Direct Current (Galvanostatic Method) for a period of 15 days under stressed and unstressed conditions. The corroded beams were tested by applying two point loads to determine the ultimate load carrying capacity and cracking pattern and the results of specimens were compared with that of the companion specimens. Gravimetric method is used to quantify corrosion that has occurred.
Abstract: Eight steel reinforced concrete beams (SRC), were
fabricated and tested under earthquake type cyclic loading. The
effectiveness of intermediate stiffeners, such as mid-span stiffener and
plastic hinge zone stiffeners, in enhancing composite action and
ductility of SRC beams was investigated. The effectiveness of
strengthened beam-to-column (SBC) and weakened beam-to-column
(WBC) connections in enhancing beam ductility was also studied. It
was found that: (1) All the specimens possessed fairly high flexural
ductility and were found adequate for structures in high seismic zones.
(2) WBC connections induced stress concentration which caused extra
damage to concrete near the flange tapering zone. This extra damage
inhibited the flexural strength development and the ductility of the
specimens with WBC connections to some extent. (3) Specimens with
SBC connections demonstrated higher flexural strength and ductility
compared to specimens with WBC connections. (4) The intermediate
stiffeners, especially combination of plastic hinge zone stiffener and
mid span stiffeners, have an obvious effect in enhancing the ductility
of the beams with SBC connection.
Abstract: The present work presents a method of calculating the
ductility of rectangular sections of beams considering nonlinear
behavior of concrete and steel. This calculation procedure allows us
to trace the curvature of the section according to the bending
moment, and consequently deduce ductility. It also allowed us to
study the various parameters that affect the value of the ductility. A
comparison of the effect of maximum rates of tension steel, adopted
by the codes, ACI [1], EC8 [2] and RPA [3] on the value of the
ductility was made. It was concluded that the maximum rate of steels
permitted by the ACI [1] codes and RPA [3] are almost similar in
their effect on the ductility and too high. Therefore, the ductility
mobilized in case of an earthquake is low, the inverse of code EC8
[2]. Recommendations have been made in this direction.
Abstract: In the present work, behavior of inoxydable steel as
reinforcement bar in composite concrete is being investigated. The
bar-concrete adherence in reinforced concrete (RC) beam is studied
and focus is made on the tension stiffening parameter. This study
highlighted an approach to observe this interaction behavior in
bending test instead of direct tension as per reported in many
references. The approach resembles actual loading condition of the
structural RC beam. The tension stiffening properties are then
applied to numerical finite element analysis (FEA) to verify their
correlation with laboratory results. Comparison with laboratory
shows a good correlation between the two. The experimental settings
is able to determine tension stiffening parameters in RC beam and
the modeling strategies made in ABAQUS can closely represent the
actual condition. Tension stiffening model used can represent the
interaction properties between inoxydable steel and concrete.
Abstract: In this paper are illustrated the principal aspects
connected with the numerical evaluation of thermal stress induced by high gradient temperature in the concrete beam. The reinforced concrete beam has many advantages over steel
beam, such as high resistance to high temperature, high resistance to thermal shock, Better resistance to fatigue and buckling, strong
resistance against, fire, explosion, etc.
The main drawback of the reinforced concrete beam is its poor resistance to tensile stresses. In order to investigate the thermal
induced tensile stresses, a numerical model of a transient thermal
analysis is presented for the evaluation of thermo-mechanical
response of concrete beam to the high temperature, taking into account the temperature dependence of the thermo physical properties of the concrete like thermal conductivity and specific heat.
Abstract: This work deals with the initial applications and formulation of an anisotropic plastic-damage constitutive model proposed for non-linear analysis of reinforced concrete structures submitted to a loading with change of the sign. The original constitutive model is based on the fundamental hypothesis of energy equivalence between real and continuous medium following the concepts of the Continuum Damage Mechanics. The concrete is assumed as an initial elastic isotropic medium presenting anisotropy, permanent strains and bimodularity (distinct elastic responses whether traction or compression stress states prevail) induced by damage evolution. In order to take into account the bimodularity, two damage tensors governing the rigidity in tension or compression regimes are introduced. Then, some conditions are introduced in the original version of the model in order to simulate the damage unilateral effect. The three-dimensional version of the proposed model is analyzed in order to validate its formulation when compared to micromechanical theory. The one-dimensional version of the model is applied in the analyses of a reinforced concrete beam submitted to a loading with change of the sign. Despite the parametric identification problems, the initial applications show the good performance of the model.
Abstract: High strength concrete (HSC) provides high strength
but lower ductility than normal strength concrete. This low ductility
limits the benefit of using HSC in building safe structures. On the
other hand, when designing reinforced concrete beams, designers
have to limit the amount of tensile reinforcement to prevent the
brittle failure of concrete. Therefore the full potential of the use of
steel reinforcement can not be achieved. This paper presents the idea
of confining concrete in the compression zone so that the HSC will
be in a state of triaxial compression, which leads to improvements in
strength and ductility. Five beams made of HSC were cast and tested.
The cross section of the beams was 200×300 mm, with a length of 4
m and a clear span of 3.6 m subjected to four-point loading, with
emphasis placed on the midspan deflection. The first beam served as
a reference beam. The remaining beams had different tensile
reinforcement and the confinement shapes were changed to gauge
their effectiveness in improving the strength and ductility of the
beams. The compressive strength of the concrete was 85 MPa and the
tensile strength of the steel was 500 MPa and for the stirrups and
helixes was 250 MPa. Results of testing the five beams proved that
placing helixes with different diameters as a variable parameter in the
compression zone of reinforced concrete beams improve their
strength and ductility.
Abstract: Experimental study on the influence of fibre content
on crack behaviour and propagation in synthetic-fibre reinforced
beams has been reported in this paper. The tensile behaviour of
metallic fibre concrete is evaluated in terms of residual flexural
tensile strength values determined from the load-crack mouth
opening displacement curve or load-deflection curve obtained by
applying a centre-point load on a simply supported notched prism.
The results achieved demonstrate that an increase in fibre content has
an almost negligible effect on compressive and tensile splitting
properties, causes a marginal increment in flexural tensile strength
and increasesthe Re3 value.