Abstract: Many industrial materials like magnets need to be
tested for the radiation environment expected at linear colliders (LC)
where the accelerator and detectors will be subjected to large
influences of beta, neutron and gamma’s over their life Gamma
irradiation of the permanent sample magnets using a 60Co source was
investigated up to an absorbed dose of 700Mrad shows a negligible
effect on some magnetic properties of Nd-Fe-B. In this work it has
been tried to investigate the change of some important properties of
Barium hexa ferrite. Results showed little decreases of magnetic
properties at doses rang of 0.5 to 2.5 Mrad. But at the gamma
irradiation dose up to 10 Mrad it is showed a few increase of
properties. Also study of gamma irradiation of Nd-Fe-B showed
considerably increase of magnetic properties.
Abstract: We present an analytical model for the calculation of
the sensitivity, the spectral current noise and the detective parameter
for an optically illuminated In0.53Ga0.47As n+nn+ diode. The
photocurrent due to the excess carrier is obtained by solving the
continuity equation. Moreover, the current noise level is evaluated at
room temperature and under a constant voltage applied between the
diode terminals. The analytical calculation of the current noise in the
n+nn+ structure is developed by considering the free carries
fluctuations. The responsivity and the detection parameter are
discussed as functions of the doping concentrations and the emitter
layer thickness in one-dimensional homogeneous n+nn+ structure.
Abstract: Silicon photonics has generated an increasing interest in recent years mainly for optical communications optical interconnects in microelectronic circuits or bio-sensing applications. The development of elementary passive and active components (including detectors and modulators), which are mainly fabricated on the silicon on insulator platform for CMOS-compatible fabrication, has reached such a performance level that the integration challenge of silicon photonics with microelectronic circuits should be addressed. Since crystalline silicon can only be grown from another silicon crystal, making it impossible to deposit in this state, the optical devices are typically limited to a single layer. An alternative approach is to integrate a photonic layer above the CMOS chip using back-end CMOS fabrication process. In this paper, various materials, including silicon nitride, amorphous silicon, and polycrystalline silicon, for this purpose are addressed.
Abstract: Single photon detectors have been fabricated NbN
nano wire. These detectors are fabricated from high quality, ultra
high vacuum sputtered NbN thin films on a sapphire substrate. In this
work a typical schematic of the nanowire Single Photon Detector
structure and then driving and measurement electronic circuit are
shown.
The response of superconducting nanowire single photon detectors
during a photo detection event, is modeled by a special electrical
circuits (two circuit).
Finally, current through the wire is calculated by solving
equations of models.
Abstract: An image compression method has been developed
using fuzzy edge image utilizing the basic Block Truncation Coding
(BTC) algorithm. The fuzzy edge image has been validated with
classical edge detectors on the basis of the results of the well-known
Canny edge detector prior to applying to the proposed method. The
bit plane generated by the conventional BTC method is replaced with
the fuzzy bit plane generated by the logical OR operation between
the fuzzy edge image and the corresponding conventional BTC bit
plane. The input image is encoded with the block mean and standard
deviation and the fuzzy bit plane. The proposed method has been
tested with test images of 8 bits/pixel and size 512×512 and found to
be superior with better Peak Signal to Noise Ratio (PSNR) when
compared to the conventional BTC, and adaptive bit plane selection
BTC (ABTC) methods. The raggedness and jagged appearance, and
the ringing artifacts at sharp edges are greatly reduced in
reconstructed images by the proposed method with the fuzzy bit
plane.
Abstract: The angular distribution of Compton scattering of two
quanta originating in the annihilation of a positron with an electron
is investigated as a quantum key distribution (QKD) mechanism in
the gamma spectral range. The geometry of coincident Compton
scattering is observed on the two sides as a way to obtain partially
correlated readings on the quantum channel. We derive the noise
probability density function of a conceptually equivalent prepare
and measure quantum channel in order to evaluate the limits of the
concept in terms of the device secrecy capacity and estimate it at
roughly 1.9 bits per 1 000 annihilation events. The high error rate
is well above the tolerable error rates of the common reconciliation
protocols; therefore, the proposed key agreement protocol by public
discussion requires key reconciliation using classical error-correcting
codes. We constructed a prototype device based on the readily
available monolithic detectors in the least complex setup.
Abstract: This article summarizes ways to verify neutron
fluence for neutron transmutation doping of silicon with phosphorus
on the LVR-15 reactor. Neutron fluence is determined using
activation detectors placed along the crystal in a strip or encapsulated
in a rod holder. Holders are placed at the centre of a water-filled
capsule or in an aluminum or silicon ingot that simulates a real single
crystal. If the diameter of the crystal is significantly less than the
capsule diameter and water from the primary circuit enters the free
space in the capsule, neutron interaction in the water changes neutron
fluence, affecting axial irradiation homogeneity. The effect of
moving the capsule vertically in the channel relative to maximum
neutron fluence in the reactor core was also measured. Even a small
shift of the capsule-s centre causes great irradiation inhomogeneity.
This effect was measured using activation detectors, and was also
confirmed by MCNP calculation.
Abstract: Ultrafast doped zinc oxide crystal promised us a good
opportunity to build new instruments for ICF fusion neutron
measurement. Two pulsed neutron detectors based on ZnO crystal
wafer have been conceptually designed, the superfast ZnO timing
detector and the scintillation recoil proton neutron detection system.
The structure of these detectors was presented, and some characters
were studied as well. The new detectors could be much faster than
existing systems, and would be more competent for ICF neutron
diagnostics.
Abstract: Efficient luminescence is reported for the first time in Eu2+ activated double Chlorides A2BCl4 (A=Alkali metal, B=Alkaline earth element). A simple wet-chemical preparation is described. Emission intensities are comparable to that of the commercial phosphor. Excitation covers near UV region. These phosphors may be useful for applications like solid state lighting, scintillation detectors and X-ray storage using photo-stimulable phosphors.
Abstract: In the present study, a support vector machine (SVM) learning approach to character recognition is proposed. Simple
feature detectors, similar to those found in the human visual system, were used in the SVM classifier. Alphabetic characters were rotated
to 8 different angles and using the proposed cognitive model, all characters were recognized with 100% accuracy and specificity.
These same results were found in psychiatric studies of human character recognition.
Abstract: Linear convolutive filters are fast in calculation and in application, and thus, often used for real-time processing of continuous data streams. In the case of transient signals, a filter has not only to detect the presence of a specific waveform, but to estimate its arrival time as well. In this study, a measure is presented which indicates the performance of detectors in achieving both of these tasks simultaneously. Furthermore, a new sub-class of linear filters within the class of filters which minimize the quadratic response is proposed. The proposed filters are more flexible than the existing ones, like the adaptive matched filter or the minimum power distortionless response beamformer, and prove to be superior with respect to that measure in certain settings. Simulations of a real-time scenario confirm the advantage of these filters as well as the usefulness of the performance measure.
Abstract: Cosmic showers, from their places of origin in space,
after entering earth generate secondary particles called Extensive Air
Shower (EAS). Detection and analysis of EAS and similar High
Energy Particle Showers involve a plethora of experimental setups
with certain constraints for which soft-computational tools like
Artificial Neural Network (ANN)s can be adopted. The optimality
of ANN classifiers can be enhanced further by the use of Multiple
Classifier System (MCS) and certain data - dimension reduction
techniques. This work describes the performance of certain data
dimension reduction techniques like Principal Component Analysis
(PCA), Independent Component Analysis (ICA) and Self Organizing
Map (SOM) approximators for application with an MCS formed
using Multi Layer Perceptron (MLP), Recurrent Neural Network
(RNN) and Probabilistic Neural Network (PNN). The data inputs are
obtained from an array of detectors placed in a circular arrangement
resembling a practical detector grid which have a higher dimension
and greater correlation among themselves. The PCA, ICA and SOM
blocks reduce the correlation and generate a form suitable for real
time practical applications for prediction of primary energy and
location of EAS from density values captured using detectors in a
circular grid.
Abstract: The measurements of 226Ra, 232Th and 40K using
gamma spectrometry and radon concentration and exhalation rates
measurements using solid state nuclear track (LR-115, Type-II
plastic) detectors are used to asses a first order exposure risk for the
persons residing in Fatehbad and Hissar districts of Western Haryana,
India. The concentration of Radium, Thorium and Potassium in the
soil samples varies from 13.37 Bq m-3 to 24.67 Bq m-3, 34.67 Bq m-3
to 67.34 Bq m-3 and 298.78 Bq m-3 to 405.67 Bq m-3 respectively
with average values of 18.78, 47.35 and 361.57 Bq m-3 respectively.
The radium equivalent activity (Raeq) calculated for the same soil
samples varies from 92.72 Bq m-3 to 140.6 Bq m-3 with an average
value of 111.80 Bq m-3. The values of absorbed dose and annual
effective dose (indoors and outdoors) are found to vary from 44.18
nGy h-1 to 65.23 nGy h-1, 0.22 mSv y-1 to 0.32 mSv y-1 and 0.05 mSv
y-1 to 0.08 mSv y-1 respectively. The radon concentration and
exhalation rates have also been reported. The radium equivalent
activities in all the soil samples were found to be lower than the limit
(370 Bq kg-1) set in the Organization for Economic Cooperation and
Development (OECD) report and the value of Hex in all the samples
is less than unity.
Abstract: In this paper, a simple heuristic genetic algorithm is
used for Multistage Multiuser detection in fast fading environments.
Multipath channels, multiple access interference (MAI) and near far
effect cause the performance of the conventional detector to degrade.
Heuristic Genetic algorithms, a rapidly growing area of artificial
intelligence, uses evolutionary programming for initial search, which
not only helps to converge the solution towards near optimal
performance efficiently but also at a very low complexity as
compared with optimal detector. This holds true for Additive White
Gaussian Noise (AWGN) and multipath fading channels.
Experimental results are presented to show the superior performance
of the proposed techque over the existing methods.
Abstract: In this paper, a novel corner detection method is
presented to stably extract geometrically important corners.
Intensity-based corner detectors such as the Harris corner can detect
corners in noisy environments but has inaccurate corner position and
misses the corners of obtuse angles. Edge-based corner detectors such
as Curvature Scale Space can detect structural corners but show
unstable corner detection due to incomplete edge detection in noisy
environments. The proposed image-based direct curvature estimation
can overcome limitations in both inaccurate structural corner detection
of the Harris corner detector (intensity-based) and the unstable corner
detection of Curvature Scale Space caused by incomplete edge
detection. Various experimental results validate the robustness of the
proposed method.
Abstract: Mixed-traffic (e.g., pedestrians, bicycles, and vehicles)
data at an intersection is one of the essential factors for intersection
design and traffic control. However, some data such as pedestrian
volume cannot be directly collected by common detectors (e.g.
inductive loop, sonar and microwave sensors). In this paper, a video
based detection algorithm is proposed for mixed-traffic data collection
at intersections using surveillance cameras. The algorithm is derived
from Gaussian Mixture Model (GMM), and uses a mergence time
adjustment scheme to improve the traditional algorithm. Real-world
video data were selected to test the algorithm. The results show that
the proposed algorithm has the faster processing speed and more
accuracy than the traditional algorithm. This indicates that the
improved algorithm can be applied to detect mixed-traffic at
signalized intersection, even when conflicts occur.
Abstract: One of the methods for detecting the target position
error in the laser tracking systems is using Four Quadrant (4Q)
detectors. If the coordinates of the target center is yielded through the
usual relations of the detector outputs, the results will be nonlinear,
dependent on the shape, target size and its position on the detector
screen. In this paper we have designed an algorithm with using
neural network that coordinates of the target center in laser tracking
systems is calculated by using detector outputs obtained from visual
modeling. With this method, the results except from the part related
to the detector intrinsic limitation, are linear and dependent from the
shape and target size.
Abstract: We prove detailed analysis of a waveguide-based Schottky barrier photodetector (SBPD) where a thin silicide film is put on the top of a silicon-on-insulator (SOI) channel waveguide to absorb light propagating along the waveguide. Taking both the confinement factor of light absorption and the wall scanning induced gain of the photoexcited carriers into account, an optimized silicide thickness is extracted to maximize the effective gain, thereby the responsivity. For typical lengths of the thin silicide film (10-20 Ðçm), the optimized thickness is estimated to be in the range of 1-2 nm, and only about 50-80% light power is absorbed to reach the maximum responsivity. Resonant waveguide-based SBPDs are proposed, which consist of a microloop, microdisc, or microring waveguide structure to allow light multiply propagating along the circular Si waveguide beneath the thin silicide film. Simulation results suggest that such resonant waveguide-based SBPDs have much higher repsonsivity at the resonant wavelengths as compared to the straight waveguidebased detectors. Some experimental results about Si waveguide-based SBPD are also reported.
Abstract: Accurate timing alignment and stability is important
to maximize the true counts and minimize the random counts in
positron emission tomography So signals output from detectors must
be centering with the two isotopes to pre-operation and fed signals
into four units of pulse-processing units, each unit can accept up to
eight inputs. The dual source computed tomography consist two units
on the left for 15 detector signals of Cs-137 isotope and two units on
the right are for 15 detectors signals of Co-60 isotope. The gamma
spectrum consisting of either single or multiple photo peaks. This
allows for the use of energy discrimination electronic hardware
associated with the data acquisition system to acquire photon counts
data with a specific energy, even if poor energy resolution detectors
are used. This also helps to avoid counting of the Compton scatter
counts especially if a single discrete gamma photo peak is emitted by
the source as in the case of Cs-137. In this study the polyenergetic
version of the alternating minimization algorithm is applied to the
dual energy gamma computed tomography problem.
Abstract: Infrared focal plane arrays (IRFPA) sensors, due to
their high sensitivity, high frame frequency and simple structure, have
become the most prominently used detectors in military applications.
However, they suffer from a common problem called the fixed pattern
noise (FPN), which severely degrades image quality and limits the
infrared imaging applications. Therefore, it is necessary to perform
non-uniformity correction (NUC) on IR image. The algorithms of
non-uniformity correction are classified into two main categories, the
calibration-based and scene-based algorithms. There exist some
shortcomings in both algorithms, hence a novel non-uniformity
correction algorithm based on non-linear fit is proposed, which
combines the advantages of the two algorithms. Experimental results
show that the proposed algorithm acquires a good effect of NUC with
a lower non-uniformity ratio.