Abstract: A four element prototype phased array surface probe
has been designed and constructed to improve clinical human
prostate spectroscopic data. The probe consists of two pairs of
adjacent rectangular coils with an optimum overlap to reduce the
mutual inductance. The two pairs are positioned on the anterior and
the posterior pelvic region and two couples of varactors at the input
of each coil undertake the procedures of tuning and matching. The
probe switches off and on automatically during the consecutive
phases of the MR experiment with the use of an analog switch that is
triggered by a microcontroller. Experimental tests that were carried
out resulted in high levels of tuning accuracy. Also, the switching
mechanism functions properly for various applied loads and pulse
sequence characteristics, producing only 10 μs of latency.
Abstract: The knowledge of the nature of loading is very
important in order to hold account on the total behavior such as
vibration, shock, fatigue, etc. Fatigue present 90% of failure when
loadings fatigues are very complex. In this paper a study of double
through crack at hole for plate subjected to fatigue loading is
presented. Various modes loading are studied where the applied load
is the same one. The fatigue life is given where the effect of stress
ratio is highlighted. This work is conducted on aluminum alloy 2024
T351 used for much aerospace and aeronautics applications. The
fatigue crack growth behavior with constant amplitude is studied
using the AFGROW code when Forman model is applied. The
fatigue crack growth rate and fatigue life for different loading modes
are compared with variation of others geometrical parameter such as
thickness and dimensions of notch hole.
Abstract: Intradiscal and intervertebral pressure transducers
were developed. They were used to map the pressures in the nucleus
and within the annulus of the human spinal segments. Their stressrelaxation
were recorded over a period of time for nucleus
pressure, applied load, and peripherial strain against time. The
results show that for normal discs, pressures in the nucleus are
viscoelastic in nature with the applied compressive load.
Mechanical strains which develop around the periphery of the
vertebral body are also viscoelastic with the applied compressive
load. Applied compressive load against time also shows viscoelastic
behavior. However, annulus does not respond viscoelastically with
the applied load. It showed a linear response to compressive loading.
Abstract: Stainless steel has been employed in many
engineering applications ranging from pharmaceutical equipment to
piping in the nuclear reactors and storage to chemical products. In
this attempt, simulation of fatigue crack growth based on
experimental results of austenitic stainless steel 304L was presented
using AFGROW code when NASGRO mode laws adopted. Double
through crack at hole specimen is used in this investigation under
constant amplitude loading. Effect of mean stress is highlighted.
Results show that fatigue crack growth rate (FCGR) and fatigue life
were affected by maximum applied load and dimension of hole. An
equivalent of Paris law for this material was estimated.
Abstract: F-actin fibrils are the cytoskeleton of osteocytes. They react in a dynamic manner to mechanical loading, and strength and
reposition their efforts to reinforce the cells structure. We hypothesize that f-actin is temporarly disrupted after loading and repolymerizes
in a new orientation to oppose the applied load. In vitro studies are conducted to determine f-actin disruption after varying mechanical stimulus parameters that are known to affect bone
formation. Results indicate that the f-actin cytoskeleton is disrupted in vitro as a function of applied mechanical stimulus parameters and
that the f-actin bundles reassemble after loading induced disruption
within 3 minutes after cessation of loading. The disruption of the factin
cytoskeleton depends on the magnitude of stretch, the numbers
of loading cycles, frequency, the insertion of rest between loading
cycles and extracellular calcium. In vivo studies also demonstrate
disruption of the f-actin cytoskeleton in cells embedded in the bone
matrix immediately after mechanical loading. These studies suggest
that adaptation of the f-actin fiber bundles of the cytoskeleton in
response to applied loads occurs by disruption and subsequent repolymerization.
Abstract: The purpose of this research study is to investigate the manner in which various loads affect the mechanical properties of the formed mild steel plates. The investigation focuses on examining the cross-sectional area of the metal plate at the centre of the formed mild steel plate. Six mild steel plates were deformed with different loads. The loads applied on the plates had a magnitude of 5 kg, 10 kg, 15 kg, 20 kg, 25 kg and 30 kg. The radius of the punching die was 120 mm and the loads were applied at room temperature. The investigations established that the applied load causes the Vickers microhardness at the cross-sectional area of the plate to increase due to strain hardening. Hence, the percentage increase of the hardness due to the load was found to be directly proportional to the increase in the load. Furthermore, the tensile test results for the parent material showed that the average Ultimate Tensile Strength (UTS) for the three samples was 308 MPa while the average Yield Strength and Percentage Elongation were 227 MPa and 38 % respectively. Similarly, the UTS of the formed components increased after the deformation of the plate, as such it can be concluded that the forming loads alter the mechanical properties of the materials by improving and strengthening the material properties.
Abstract: This paper presents the design of a ring-shaped tri-axial fore sensor that can be incorporated into the tip of a guidewire for use in minimally invasive surgery (MIS). The designed sensor comprises a ring-shaped structure located at the center of four cantilever beams. The ringdesign allows surgical tools to be easily passed through which largely simplified the integration process. Silicon nanowires (SiNWs) are used aspiezoresistive sensing elementsembeddedon the four cantilevers of the sensor to detect the resistance change caused by the applied load.An integration scheme with new designed guidewire tip structure having two coils at the distal end is presented. Finite element modeling has been employed in the sensor design to find the maximum stress location in order to put the SiNWs at the high stress regions to obtain maximum output. A maximum applicable force of 5 mN is found from modeling. The interaction mechanism between the designed sensor and a steel wire has been modeled by FEM. A linear relationship between the applied load on the steel wire and the induced stress on the SiNWs were observed.
Abstract: When the foundations of structures under cyclic
loading with amplitudes less than their permissible load, the concern exists often for the amount of uniform and non-uniform settlement of
such structures. Storage tank foundations with numerous filling and discharging and railways ballast course under repeating
transportation loads are examples of such conditions. This paper
deals with the effects of using the new generation of reinforcements,
Grid-Anchor, for the purpose of reducing the permanent settlement
of these foundations under the influence of different proportions of
the ultimate load. Other items such as the type and the number of
reinforcements as well as the number of loading cycles are studied numerically. Numerical models were made using the Plaxis3D
Tunnel finite element code. The results show that by using gridanchor
and increasing the number of their layers in the same
proportion as that of the cyclic load being applied, the amount of
permanent settlement decreases up to 42% relative to unreinforced
condition depends on the number of reinforcement layers and percent
of applied load and the number of loading cycles to reach a constant
value of dimensionless settlement decreases up to 20% relative to
unreinforced condition.