Abstract: This paper presents the significant factor and give
some suggestion that should know before design. The main objective of this paper is guide the first step for someone who attends to design of grounding system before study in details later. The overview of
grounding system can protect damage from fault such as can save a human life and power system equipment. The unsafe conditions have
three cases. Case 1) maximum touch voltage exceeds the safety
criteria. In this case, the conductor compression ratio of the ground gird should be first adjusted to have optimal spacing of ground grid
conductors. If it still over limit, earth resistivity should be consider afterward. Case 2) maximum step voltage exceeds the safety criteria.
In this case, increasing the number of ground grid conductors around
the boundary can solve this problem. Case 3) both of maximum touch
and step voltage exceed the safety criteria. In this case, follow the solutions explained in case 1 and case 2. Another suggestion, vary depth of ground grid until maximum step and touch voltage do not
exceed the safety criteria.
Abstract: With Power system movement toward restructuring along with factors such as life environment pollution, problems of transmission expansion and with advancement in construction technology of small generation units, it is expected that small units like wind turbines, fuel cells, photovoltaic, ... that most of the time connect to the distribution networks play a very essential role in electric power industry. With increase in developing usage of small generation units, management of distribution networks should be reviewed. The target of this paper is to present a new method for optimal management of active and reactive power in distribution networks with regard to costs pertaining to various types of dispersed generations, capacitors and cost of electric energy achieved from network. In other words, in this method it-s endeavored to select optimal sources of active and reactive power generation and controlling equipments such as dispersed generations, capacitors, under load tapchanger transformers and substations in a way that firstly costs in relation to them are minimized and secondly technical and physical constraints are regarded. Because the optimal management of distribution networks is an optimization problem with continuous and discrete variables, the new evolutionary method based on Ant Colony Algorithm has been applied. The simulation results of the method tested on two cases containing 23 and 34 buses exist and will be shown at later sections.
Abstract: Wind farms (WFs) with high level of penetration are
being established in power systems worldwide more rapidly than
other renewable resources. The Independent System Operator (ISO),
as a policy maker, should propose appropriate places for WF
installation in order to maximize the benefits for the investors. There
is also a possibility of congestion relief using the new installation of
WFs which should be taken into account by the ISO when proposing
the locations for WF installation. In this context, efficient wind farm
(WF) placement method is proposed in order to reduce burdens on
congested lines. Since the wind speed is a random variable and load
forecasts also contain uncertainties, probabilistic approaches are used
for this type of study. AC probabilistic optimal power flow (P-OPF)
is formulated and solved using Monte Carlo Simulations (MCS). In
order to reduce computation time, point estimate methods (PEM) are
introduced as efficient alternative for time-demanding MCS.
Subsequently, WF optimal placement is determined using generation
shift distribution factors (GSDF) considering a new parameter
entitled, wind availability factor (WAF). In order to obtain more
realistic results, N-1 contingency analysis is employed to find the
optimal size of WF, by means of line outage distribution factors
(LODF). The IEEE 30-bus test system is used to show and compare
the accuracy of proposed methodology.
Abstract: This paper presents the results of a comprehensive
investigation of five blackouts that occurred on 28 August to 8
September 2011 due to bushing failures of the 132/33 kV, 125 MVA
transformers at JBB Ali Grid station. The investigation aims to
explore the root causes of the bushing failures and come up with
recommendations that help in rectifying the problem and avoiding the
reoccurrence of similar type of incidents. The incident reports about
the failed bushings and the SCADA reports at this grid station were
examined and analyzed. Moreover, comprehensive power quality
field measurements at ten 33/11 kV substations (S/Ss) in JBB Ali
area were conducted, and frequency scans were performed to verify
any harmonic resonance frequencies due to power factor correction
capacitors. Furthermore, the daily operations of the on-load tap
changers (OLTCs) of both the 125 MVA and 20 MVA transformers
at JBB Ali Grid station have been analyzed. The investigation
showed that the five bushing failures were due to a local problem, i.e.
internal degradation of the bushing insulation. This has been
confirmed by analyzing the time interval between successive OLTC
operations of the faulty grid transformers. It was also found that
monitoring the number of OLTC operations can help in predicting
bushing failure.
Abstract: In this paper, we propose the Modified Synchronous Detection (MSD) Method for determining the reference compensating currents of the shunt active power filter under non sinusoidal voltages conditions. For controlling the inverter switching we used the PI regulator. The numerical simulation results, using Power System Blockset Toolbox PSB of Matlab, from a complete structure, are presented and discussed.
Abstract: In recent years the large scale use of the power electronic equipment has led to an increase of harmonics in the power system. The harmonics results into a poor power quality and have great adverse economical impact on the utilities and customers. Current harmonics are one of the most common power quality problems and are usually resolved by using shunt active filter (SHAF). The main objective of this work is to develop PI and Fuzzy logic controllers (FLC) to analyze the performance of Shunt Active Filter for mitigating current harmonics under balanced and unbalanced sinusoidal source voltage conditions for normal load and increased load. When the supply voltages are ideal (balanced), both PI and FLC are converging to the same compensation characteristics. However, the supply voltages are non-ideal (unbalanced), FLC offers outstanding results. Simulation results validate the superiority of FLC with triangular membership function over the PI controller.
Abstract: This paper proposes a novel solution for optimizing
the size and communication overhead of a distributed multiagent
system without compromising the performance. The proposed approach
addresses the challenges of scalability especially when the
multiagent system is large. A modified spectral clustering technique
is used to partition a large network into logically related clusters.
Agents are assigned to monitor dedicated clusters rather than monitor
each device or node. The proposed scalable multiagent system is
implemented using JADE (Java Agent Development Environment)
for a large power system. The performance of the proposed topologyindependent
decentralized multiagent system and the scalable multiagent
system is compared by comprehensively simulating different
fault scenarios. The time taken for reconfiguration, the overall computational
complexity, and the communication overhead incurred are
computed. The results of these simulations show that the proposed
scalable multiagent system uses fewer agents efficiently, makes faster
decisions to reconfigure when a fault occurs, and incurs significantly
less communication overhead.
Abstract: In this paper, the modelling and design of artificial neural network architecture for load forecasting purposes is investigated. The primary pre-requisite for power system planning is to arrive at realistic estimates of future demand of power, which is known as Load Forecasting. Short Term Load Forecasting (STLF) helps in determining the economic, reliable and secure operating strategies for power system. The dependence of load on several factors makes the load forecasting a very challenging job. An over estimation of the load may cause premature investment and unnecessary blocking of the capital where as under estimation of load may result in shortage of equipment and circuits. It is always better to plan the system for the load slightly higher than expected one so that no exigency may arise. In this paper, a load-forecasting model is proposed using a multilayer neural network with an appropriately modified back propagation learning algorithm. Once the neural network model is designed and trained, it can forecast the load of the power system 24 hours ahead on daily basis and can also forecast the cumulative load on daily basis. The real load data that is used for the Artificial Neural Network training was taken from LDC, Gujarat Electricity Board, Jambuva, Gujarat, India. The results show that the load forecasting of the ANN model follows the actual load pattern more accurately throughout the forecasted period.
Abstract: In this work Artificial Intelligence (AI) techniques like Fuzzy logic, Genetic Algorithms and Particle Swarm Optimization have been used to improve the performance of the Automatic Generation Control (AGC) system. Instead of applying Genetic Algorithms and Particle swarm optimization independently for optimizing the parameters of the conventional AGC with PI controller, an intelligent tuned Fuzzy logic controller (acting as the secondary controller in the AGC system) has been designed. The controller gives an improved dynamic performance for both hydrothermal and thermal-thermal power systems under a variety of operating conditions.
Abstract: The load frequency control problem of power systems has attracted a lot of attention from engineers and researchers over the years. Increasing and quickly changing load demand, coupled with the inclusion of more generators with high variability (solar and wind power generators) on the network are making power systems more difficult to regulate. Frequency changes are unavoidable but regulatory authorities require that these changes remain within a certain bound. Engineers are required to perform the tricky task of adjusting the control system to maintain the frequency within tolerated bounds. It is well known that to minimize frequency variations, a large proportional feedback gain (speed regulation constant) is desirable. However, this improvement in performance using proportional feedback comes about at the expense of a reduced stability margin and also allows some steady-state error. A conventional PI controller is then included as a secondary control loop to drive the steadystate error to zero. In this paper, we propose a robust controller to replace the conventional PI controller which guarantees performance and stability of the power system over the range of variation of the speed regulation constant. Simulation results are shown to validate the superiority of the proposed approach on a simple single-area power system model.
Abstract: This paper proposes transient angle stability
agents to enhance power system stability. The proposed transient
angle stability agents divided into two strategy agents. The
first strategy agent is a prediction agent that will predict power
system instability. According to the prediction agent-s output,
the second strategy agent, which is a control agent, is automatically
calculating the amount of active power reduction that can
stabilize the system and initiating a control action. The control
action considered is turbine fast valving. The proposed strategies
are applied to a realistic power system, the IEEE 50-
generator system. Results show that the proposed technique can
be used on-line for power system instability prediction and control.
Abstract: This paper presents features that characterize power
quality disturbances from recorded voltage waveforms using wavelet
transform. The discrete wavelet transform has been used to detect
and analyze power quality disturbances. The disturbances of interest
include sag, swell, outage and transient. A power system network has
been simulated by Electromagnetic Transients Program. Voltage
waveforms at strategic points have been obtained for analysis, which
includes different power quality disturbances. Then wavelet has been
chosen to perform feature extraction. The outputs of the feature
extraction are the wavelet coefficients representing the power quality
disturbance signal. Wavelet coefficients at different levels reveal the
time localizing information about the variation of the signal.
Abstract: An Optimal Power Flow based on Improved Particle
Swarm Optimization (OPF-IPSO) with Generator Capability Curve
Constraint is used by NN-OPF as a reference to get pattern of
generator scheduling. There are three stages in Designing NN-OPF.
The first stage is design of OPF-IPSO with generator capability curve
constraint. The second stage is clustering load to specific range and
calculating its index. The third stage is training NN-OPF using
constructive back propagation method. In training process total load
and load index used as input, and pattern of generator scheduling
used as output. Data used in this paper is power system of Java-Bali.
Software used in this simulation is MATLAB.
Abstract: The new idea of analyze of power system failure with
use of artificial neural network is proposed. An analysis of the
possibility of simulating phenomena accompanying system faults and
restitution is described. It was indicated that the universal model for
the simulation of phenomena in whole analyzed range does not exist.
The main classic method of search of optimal structure and
parameter identification are described shortly. The example with
results of calculation is shown.
Abstract: Static synchronous compensator (STATCOM) is a shunt connected voltage source converter (VSC), which can affect rapid control of reactive flow in the transmission line by controlling the generated a.c. voltage. The main aim of the paper is to design a power system installed with a Static synchronous compensator (STATCOM) and demonstrates the application of the linearised Phillips-heffron model in analyzing the damping effect of the STATCOM to improve power system oscillation stability. The proposed PI controller is designed to coordinate two control inputs: Voltage of the injection bus and capacitor voltage of the STATCOM, to improve the Dynamic stability of a SMIB system .The power oscillations damping (POD) control and power system stabilizer (PSS) and their coordinated action with proposed controllers are tested. The simulation result shows that the proposed damping controllers provide satisfactory performance in terms of improvements of dynamic stability of the system.
Abstract: This paper proposes a methodology for mitigating the occurrence of cascading failure in stressed power systems. The methodology is essentially based on predicting voltage instability in the power system using a voltage stability index and then devising a corrective action in order to increase the voltage stability margin. The paper starts with a brief description of the cascading failure mechanism which is probable root cause of severe blackouts. Then, the voltage instability indices are introduced in order to evaluate stability limit. The aim of the analysis is to assure that the coordination of protection, by adopting load shedding scheme, capable of enhancing performance of the system after the major location of instability is determined. Finally, the proposed method to generate instability prediction is introduced.
Abstract: This paper presents a new approach for setting
frequency relays based on the dynamic of power system. A
simplified model of the power system based on the load-frequency
control loop will be developed to be used instead of the complete
model of the power system. The effects of the equipments and their
responses on the frequency variations of the power plant will be
investigated and then a method for adaptive settings of frequency
relays will be explained. The proposed method will be investigated
by analyzing a simplified model of a power plant by MATLAB
software.
Abstract: The application of a Static Synchronous Series Compensator (SSSC) controller to improve the transient stability performance of a power system is thoroughly investigated in this paper. The design problem of SSSC controller is formulated as an optimization problem and Particle Swarm Optimization (PSO) Technique is employed to search for optimal controller parameters. By minimizing the time-domain based objective function, in which the deviation in the oscillatory rotor angle of the generator is involved; transient stability performance of the system is improved. The proposed controller is tested on a weakly connected power system subjected to different severe disturbances. The non-linear simulation results are presented to show the effectiveness of the proposed controller and its ability to provide efficient damping of low frequency oscillations. It is also observed that the proposed SSSC controller improves greatly the voltage profile of the system under severe disturbances.
Abstract: This paper presents a comparative study on two most
popular control strategies for Permanent Magnet Synchronous Motor
(PMSM) drives: field-oriented control (FOC) and direct torque
control (DTC). The comparison is based on various criteria including
basic control characteristics, dynamic performance, and
implementation complexity. The study is done by simulation using
the Simulink Power System Blockset that allows a complete
representation of the power section (inverter and PMSM) and the
control system. The simulation and evaluation of both control
strategies are performed using actual parameters of Permanent
Magnet Synchronous Motor fed by an IGBT PWM inverter.
Abstract: Variable speed drives are growing and varying. Drives expanse depend on progress in different part of science like power system, microelectronic, control methods, and so on. Artificial intelligent contains hard computation and soft computation. Artificial intelligent has found high application in most nonlinear systems same as motors drive. Because it has intelligence like human but there are no sentimental against human like angriness and.... Artificial intelligent is used for various points like approximation, control, and monitoring. Because artificial intelligent techniques can use as controller for any system without requirement to system mathematical model, it has been used in electrical drive control. With this manner, efficiency and reliability of drives increase and volume, weight and cost of them decrease.