New Multisensor Data Fusion Method Based on Probabilistic Grids Representation

A new data fusion method called joint probability density matrix (JPDM) is proposed, which can associate and fuse measurements from spatially distributed heterogeneous sensors to identify the real target in a surveillance region. Using the probabilistic grids representation, we numerically combine the uncertainty regions of all the measurements in a general framework. The NP-hard multisensor data fusion problem has been converted to a peak picking problem in the grids map. Unlike most of the existing data fusion method, the JPDM method dose not need association processing, and will not lead to combinatorial explosion. Its convergence to the CRLB with a diminishing grid size has been proved. Simulation results are presented to illustrate the effectiveness of the proposed technique.

Cannabidiol Treatment Ameliorates Acetaminophen-Induced Hepatotoxicity in Mice

The possible therapeutic effect of cannabidiol, the major non-psychotropic Cannabis constituent, was investigated against acute hepatotoxicity induced by a single oral dose of acetaminophen (500mg/kg) in mice. Cannabidiol (two intraperitoneal injections, 5mg/kg, each) was given 1 hour and 12 hours following acetaminophen administration. Acetaminophen administration caused significant elevations of serum alanine aminotransferase, and hepatic malondialdehyde, and nitric oxide levels, and a significant decrease in hepatic reduced glutathione. Cannabidiol significantly attenuated the deterioration in the measured biochemical parameters resulted from acetaminophen administration. Also, histopathological examination showed that cannabidiol markedly attenuated ameliorated acetaminophen-induced liver tissue damage. These results emphasize that cannabidiol represents a potential therapeutic option to protect against acetaminophen hepartotoxicity which is a common clinical problem.

Effect of L-Arginine on Neuromuscular Transmission of the Chick Biventer Cervicis Muscle

In this study, the effect of L-arginine was examined at the neuromuscular junction of the chick biventer cervicis muscle. LArginine at 500 μg/ ml, decreased twitch response to electerical stimulation, and produced rightward shift of the dose- response curve for acetylcholine or carbachol. L-Arginine at 1000μg/ ml produced a strong shift to the right of the dose – response curve for acetylcholine or carbachol with a reduction in the efficacy. The inhibitory effect of L-arginine on the twitch response was blocked by caffeine (200μg/ ml). NO levels were also measured in the chick biventer cervicis muscle homogenates, using spectrophotometric method for the direct detection of NO, nitrite and nitrate. Total nitrite (nitrite + nitrate) was measured by a spectrophotometer at 540 nm after the conversion of nitrate to nitrite by copperized cadmium granules. NO levels were found to be significantly increased in concentrations 500 and 1000μg/ ml of L-arginine in comparison with the control group (p

Effect of Bio-Nitrogen as a Partial Alternative to Mineral-Nitrogen Fertiliser on Growth, Nitrate and Nitrite Contents, and Yield Quality in Brassica oleracea L.

Effects of bio-nitrogen fertilizer (bio-N), as a partial alternative to mineral-nitrogen fertilizer (mineral-N), on growth, yield and yield quality of broccoli plants were investigated. Bio-N was applied at 1, 2 or 3 doses in combination with 65% of the recommended dose of mineral-N (bio-N1, bio-N2 or bio-N3 + ⅔mineral-N). However, 100% of the recommended dose of mineral- N was applied as a control. Significant positive influences of the bio- N3 + ⅔mineral-N treatment were observed on growth traits, leaf contents of nitrogen, phosphorus, potassium, nitrate and nitrite, and yield quality when compared to the other two combined treatments. In contrast, there were no significant differences in these parameters between the bio-N3 + ⅔mineral-N and the control treatments, except for leaf contents of nitrate and nitrite. They showed lower contents in the bio-N3 + ⅔mineral-N treatment than the control. Therefore, we recommend using bio-N as a partial alternative to mineral-N for healthy nutrition.

Use of Agricultural Waste for the Removal of Nickel Ions from Aqueous Solutions: Equilibrium and Kinetics Studies

The potential of economically cheaper cellulose containing natural materials like rice husk was assessed for nickel adsorption from aqueous solutions. The effects of pH, contact time, sorbent dose, initial metal ion concentration and temperature on the uptake of nickel were studied in batch process. The removal of nickel was dependent on the physico-chemical characteristics of the adsorbent, adsorbate concentration and other studied process parameters. The sorption data has been correlated with Langmuir, Freundlich and Dubinin-Radush kevich (D-R) adsorption models. It was found that Freundlich and Langmuir isotherms fitted well to the data. Maximum nickel removal was observed at pH 6.0. The efficiency of rice husk for nickel removal was 51.8% for dilute solutions at 20 g L-1 adsorbent dose. FTIR, SEM and EDAX were recorded before and after adsorption to explore the number and position of the functional groups available for nickel binding on to the studied adsorbent and changes in surface morphology and elemental constitution of the adsorbent. Pseudo-second order model explains the nickel kinetics more effectively. Reusability of the adsorbent was examined by desorption in which HCl eluted 78.93% nickel. The results revealed that nickel is considerably adsorbed on rice husk and it could be and economic method for the removal of nickel from aqueous solutions.

Effect of Oral Administration of “Gadagi“ Tea on Liver Function in Rats

Effect of oral administration of “Gadagi" tea on liver function was assessed on 50 healthy male albino rats which were grouped and administered with different doses(mg/kg) i.e low dose (380mg/kg, 415mg/kg, 365mg/kg, 315mg/kg for “sak", “sada" and “magani" respectively), standard dose ( 760mg/kg, 830mg/kg, 730mg/kg for “sak-, “sada" and “magani" respectively) and high dose (1500mg/kg, 1700mg/kg and 1460mg/kg for “sak--,"sada" and “magani" groups respectively) for a period of four weeks. Animals that were not administered with the tea constituted the control group. At the end of fourth week, the animals were sacrificed and their serum alanine aminotransferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase (ALP), total protein (TP), albumin (ALB), and globulins (GLO) were determined. Mean serum ALT and ALP activities were significantly higher (P

A New Splitting H1-Galerkin Mixed Method for Pseudo-hyperbolic Equations

A new numerical scheme based on the H1-Galerkin mixed finite element method for a class of second-order pseudohyperbolic equations is constructed. The proposed procedures can be split into three independent differential sub-schemes and does not need to solve a coupled system of equations. Optimal error estimates are derived for both semidiscrete and fully discrete schemes for problems in one space dimension. And the proposed method dose not requires the LBB consistency condition. Finally, some numerical results are provided to illustrate the efficacy of our method.

The Removal of As(V) from Drinking Waters by Coagulation Process using Iron Salts

In this study arsenate [As(V)] removal from drinking water by coagulation process was investigated. Ferric chloride (FeCl3.6H2O) and ferrous sulfate (FeSO4.7H2O) were used as coagulant. The effects of major operating variables such as coagulant dose (1–30 mg/L) and pH (5.5–9.5) were investigated. Ferric chloride and ferrous sulfate were found as effective and reliable coagulant due to required dose, residual arsenate and coagulant concentration. Optimum pH values for maximum arsenate removal for ferrous sulfate and ferric chloride were found as 8 and 7.5. The arsenate removal efficiency decreased at neutral and acidic pH values for Fe(II) and at the high acidic and high alkaline pH for Fe(III). It was found that the increase of coagulant dose caused a substantial increase in the arsenate removal. But above a certain ferric chloride and ferrous sulfate dosage, the increase in arsenate removal was not significant. Ferric chloride and ferrous sulfate dose above 8 mg/L slightly increased arsenate removal.

Effects of Data Correlation in a Sparse-View Compressive Sensing Based Image Reconstruction

Computed tomography and laminography are heavily investigated in a compressive sensing based image reconstruction framework to reduce the dose to the patients as well as to the radiosensitive devices such as multilayer microelectronic circuit boards. Nowadays researchers are actively working on optimizing the compressive sensing based iterative image reconstruction algorithm to obtain better quality images. However, the effects of the sampled data’s properties on reconstructed the image’s quality, particularly in an insufficient sampled data conditions have not been explored in computed laminography. In this paper, we investigated the effects of two data properties i.e. sampling density and data incoherence on the reconstructed image obtained by conventional computed laminography and a recently proposed method called spherical sinusoidal scanning scheme. We have found that in a compressive sensing based image reconstruction framework, the image quality mainly depends upon the data incoherence when the data is uniformly sampled.

A Study on Fuzzy Adaptive Control of Enteral Feeding Pump

Recent medical studies have investigated the importance of enteral feeding and the use of feeding pumps for recovering patients unable to feed themselves or gain nourishment and nutrients by natural means. The most of enteral feeding system uses a peristaltic tube pump. A peristaltic pump is a form of positive displacement pump in which a flexible tube is progressively squeezed externally to allow the resulting enclosed pillow of fluid to progress along it. The squeezing of the tube requires a precise and robust controller of the geared motor to overcome parametric uncertainty of the pumping system which generates due to a wide variation of friction and slip between tube and roller. So, this paper proposes fuzzy adaptive controller for the robust control of the peristaltic tube pump. This new adaptive controller uses a fuzzy multi-layered architecture which has several independent fuzzy controllers in parallel, each with different robust stability area. Out of several independent fuzzy controllers, the most suited one is selected by a system identifier which observes variations in the controlled system parameter. This paper proposes a design procedure which can be carried out mathematically and systematically from the model of a controlled system. Finally, the good control performance, accurate dose rate and robust system stability, of the developed feeding pump is confirmed through experimental and clinic testing.

The effect of Gamma Irradiation on the Nutritional Properties of Functional Products of the Green Banana

Banana is one of the most consumed fruits in the tropics and subtropics. Brazil accounts for about 9% of the world banana production. However, the production losses are as high as 30 to 40% and even much higher in some developing countries. The green banana flour is a complex carbohydrate source, including a high total starch (73.4%), resistant starch (17.5%) with functional properties. Gamma irradiation is considered to be an alternative method for food preservation. It has been performed due to the need of extending the shelf - life of foods, whilst maintaining their safety and avoiding one of the main concerns: the nutrient loss. In this work data about on the effects of ionizing radiation on the physicochemical analysis (carbohydrate, proteins, lipids, alimentary fiber, moistures and ashes) of Brazilian functional products (biscuits and bread) of the green banana pulp are presented. The caloric value was calculated. No significant difference was observed between the samples of irradiated and non – irradiated green banana biscuits with the following determinations: carbohydrates, proteins, alimentary fiber and ashes. Only a small significant difference was found in lipids (macronutrients). The results of physical chemical analysis of the irradiated and non- irradiated green banana bread non- irradiated showed no significant difference with the following determinations: carbohydrates, lipids (macronutrients), moisture, ashes and caloric value. A small difference was found in proteins (macronutrients). Irradiation of functional products (biscuits and bread) with doses of 1 and 3kGy maintained their original macronutrients content, showing good radioresistance.

Determination of the Specific Activity of Soil and Fertilizers in Sergipe - Brazil

Measurements of radioactivity in the environment is of great importance to monitor and control the levels of radiation to which man is exposed directly or indirectly. It is necessary to show that regardless of working or being close to nuclear power plants, people are daily in contact with some amount of radiation from the actual environment and food that are ingested, contradicting the view of most of them. The aim of this study was to analyze the rate of natural and artificial radiation from radionuclides present in cement, soil and fertilizers used in Sergipe State – Brazil. The radionuclide activitiesmeasured all samples arebelow the Brazilian limit of the exclusion and exemption criteria from the requirement of radiation protection.It was detected Be-7 in organic fertilizers that means a short interval between the brewing processes for use in agriculture. It was also detected an unexpected Cs-137 in some samples; however its activities does not represent risk for the population. Th-231 was also found in samples of soil and cement in the state of Sergipe that is an unprecedented result.

Protein Profiling in Alanine Aminotransferase Induced Patient cohort using Acetaminophen

Sensitive and predictive DILI (Drug Induced Liver Injury) biomarkers are needed in drug R&D to improve early detection of hepatotoxicity. The discovery of DILI biomarkers that demonstrate the predictive power to identify individuals at risk to DILI would represent a major advance in the development of personalized healthcare approaches. In this healthy volunteer acetaminophen study (4g/day for 7 days, with 3 monitored nontreatment days before and 4 after), 450 serum samples from 32 subjects were analyzed using protein profiling by antibody suspension bead arrays. Multiparallel protein profiles were generated using a DILI target protein array with 300 antibodies, where the antibodies were selected based on previous literature findings of putative DILI biomarkers and a screening process using pre dose samples from the same cohort. Of the 32 subjects, 16 were found to develop an elevated ALT value (2Xbaseline, responders). Using the plasma profiling approach together with multivariate statistical analysis some novel findings linked to lipid metabolism were found and more important, endogenous protein profiles in baseline samples (prior to treatment) with predictive power for ALT elevations were identified.

Shrinkage of High Strength Concrete

This paper presents the results of an experimental investigation carried out to evaluate the shrinkage of High Strength Concrete. High Strength Concrete is made by partially replacement of cement by flyash and silica fume. The shrinkage of High Strength Concrete has been studied using the different types of coarse and fine aggregates i.e. Sandstone and Granite of 12.5 mm size and Yamuna and Badarpur Sand. The Mix proportion of concrete is 1:0.8:2.2 with water cement ratio as 0.30. Superplasticizer dose @ of 2% by weight of cement is added to achieve the required degree of workability in terms of compaction factor. From the test results of the above investigation it can be concluded that the shrinkage strain of High Strength Concrete increases with age. The shrinkage strain of concrete with replacement of cement by 10% of Flyash and Silica fume respectively at various ages are more (6 to 10%) than the shrinkage strain of concrete without Flyash and Silica fume. The shrinkage strain of concrete with Badarpur sand as Fine aggregate at 90 days is slightly less (10%) than that of concrete with Yamuna Sand. Further, the shrinkage strain of concrete with Granite as Coarse aggregate at 90 days is slightly less (6 to 7%) than that of concrete with Sand stone as aggregate of same size. The shrinkage strain of High Strength Concrete is also compared with that of normal strength concrete. Test results show that the shrinkage strain of high strength concrete is less than that of normal strength concrete.

Dexamethasone: Impact on Testicular Activity

Dexamethasone (Dex) is a synthetic glucocorticoid that is used in therapy. However prolonged treatments with high doses are often required. This causes side effects that interfere with the activity of several endocrine systems, including the gonadotropic axis. The aim of our study is to determine the effect of Dex on testicular function in prepubertal Wistar rats. Newborn Wistar rats are submitted to intraperitoneal injection of Dex (1μg of Dex dissolved in NaCl 0.9% / 5g bw) for 20 days and then sacrificed at the age of 40days. A control group received NaCl 0.9%. The rat is weighed daily. The plasmatic levels of testosterone, LH and FSH were measured by radioimmunoassay. A histomorphometric study was performed on sections of testis. Treated groups showed a significant decrease in body weight (p

Phytotoxicity of Daphne Gnidium L. Occurring in Tunisia

Phytotoxicity of Daphne gnidium L. was evaluated through the effect of incorporating leaves, stems and roots biomass into soil (at 12.5, 25, 50g/Kg) and irrigation by their aqueous extracts (50g/L), on the growth of two crops (Lactuca sativa L. and Raphanus sativus L.) and two weeds (Peaganum harmala L. and Scolymus maculatus L.). Results revealed a perceptible phytotoxic effect which increased with dose and concentration. At the highest dose, roots and leaves residues was the most toxic and caused total inhibition respectively, for lettuce and thistle seedling growth. Irrigation with aqueous extracts of D. gnidium different organs decreased also seedlings length of all test species. Stems extract was more inhibitor on thistle than peganum seedling growth; it induced a significant reduction of 80% and 67%, for, respectively, roots and shoots. Results of the present study suggest that different organs of D. gnidium could be exploited in the management of agro-ecosystems.

Effect of Local Dual Frequency Sonication on Drug Distribution from Nanomicelles

The nanosized polymeric micelles release the drug due to acoustic cavitation, which is enhanced in dual frequency ultrasonic fields. In this study, adult female Balb/C mice were transplanted with spontaneous breast adenocarcinoma tumors and were injected with a dose of 1.3 mg/kg doxorubicin in one of three forms: free doxorubicin, micellar doxorubicin without sonication and micellar doxorubicin with sonication. To increase cavitation yield, the tumor region was sonicated with low level dual frequency of 3 MHz and 28 kHz. The animals were sacrificed 24 h after injection, and their tumor, heart, spleen, liver, kidneys and plasma were separated and homogenized. The drug content in their tumor, heart, spleen, liver, kidneys and plasma was determined using tissue fluorimetry. The results show that in the group that received micellar doxorubicin with sonication, the drug concentration in the tumor tissue was nine and three times higher than in the free doxorubicin group and the micellar doxorubicin without sonication group, respectively. In the micellar doxorubicin with sonication group, the drug concentration in other tissues was lower than other groups (p

Defluoridation of Water by Schwertmannite

In the present study Schwertmannite (an iron oxide hydroxide) is selected as an adsorbent for defluoridation of water. The adsorbent was prepared by wet chemical process and was characterized by SEM, XRD and BET. The fluoride adsorption efficiency of the prepared adsorbent was determined with respect to contact time, initial fluoride concentration, adsorbent dose and pH of the solution. The batch adsorption data revealed that the fluoride adsorption efficiency was highly influenced by the studied factors. Equilibrium was attained within one hour of contact time indicating fast kinetics and the adsorption data followed pseudo second order kinetic model. Equilibrium isotherm data fitted to both Langmuir and Freundlich isotherm models for a concentration range of 5-30 mg/L. The adsorption system followed Langmuir isotherm model with maximum adsorption capacity of 11.3 mg/g. The high adsorption capacity of Schwertmannite points towards the potential of this adsorbent for fluoride removal from aqueous medium.

Kerma Profile Measurements in CT Chest Scans– a Comparison of Methodologies

The Brazilian legislation has only established diagnostic reference levels (DRLs) in terms of Multiple Scan Average Dose (MSAD) as a quality control parameter for computed tomography (CT) scanners. Compliance with DRLs can be verified by measuring the Computed Tomography Kerma Index (Ca,100) with a pencil ionization chamber or by obtaining the kerma distribution in CT scans with radiochromic films or rod shape lithium fluoride termoluminescent dosimeters (TLD-100). TL dosimeters were used to record kerma profiles and to determine MSAD values of a Bright Speed model GE CT scanner. Measurements were done with radiochromic films and TL dosimeters distributed in cylinders positioned in the center and in four peripheral bores of a standard polymethylmethacrylate (PMMA) body CT dosimetry phantom. Irradiations were done using a protocol for adult chest. The maximum values were found at the midpoint of the longitudinal axis. The MSAD values obtained with three dosimetric techniques were compared.

Workplace Monitoring During Interventional Cardiology Procedures

Interventional cardiologists are at greater risk from radiation exposure as a result of the procedures they undertake than most other medical specialists. A study was performed to evaluate operator dose during interventional cardiology procedures and to establish methods of operator dose reduction with a radiation protective device. Different procedure technique and use of protective tools can explain big difference in the annual equivalent dose received by the professionals. Strategies to prevent and monitor radiation exposure, advanced protective shielding and effective radiation monitoring methods should be applied.