Abstract: This study carried out comparative seismic
performance of reinforced concrete frames infilled by masonry walls
with different heights. Partial and fully infilled reinforced concrete
frames were modeled for the research objectives and the analysis
model for a bare reinforced concrete frame was also established for
comparison. Non–linear static analyses for the studied frames were
performed to investigate their structural behavior under extreme
seismic loads and to find out their collapse mechanism. It was
observed from analysis results that the strengths of the partial infilled
reinforced concrete frames are increased and their ductilities are
reduced, as infilled masonry walls are higher. Especially, reinforced
concrete frames with higher partial infilled masonry walls would
experience shear failures. Non–linear dynamic analyses using 10
earthquake records show that the bare and fully infilled reinforced
concrete frame present stable collapse mechanism while the reinforced
concrete frames with partially infilled masonry walls collapse in more
brittle manner due to short-column effects.
Abstract: Building loss estimation methodologies which have
been advanced considerably in recent decades are usually used to
estimate socio and economic impacts resulting from seismic structural
damage. In accordance with these methods, this paper presents the
evaluation of an annual loss probability of a reinforced concrete
moment resisting frame designed according to Korean Building Code.
The annual loss probability is defined by (1) a fragility curve obtained
from a capacity spectrum method which is similar to a method adopted
from HAZUS, and (2) a seismic hazard curve derived from annual
frequencies of exceedance per peak ground acceleration. Seismic
fragilities are computed to calculate the annual loss probability of a
certain structure using functions depending on structural capacity,
seismic demand, structural response and the probability of exceeding
damage state thresholds. This study carried out a nonlinear static
analysis to obtain the capacity of a RC moment resisting frame
selected as a prototype building. The analysis results show that the
probability of being extensive structural damage in the prototype
building is expected to 0.01% in a year.
Abstract: An existing RC building in Madinah is seismically
evaluated with and without infill wall. Four model systems have been
considered i.e. model I (no infill), model IIA (strut infill-update from
field test), model IIB (strut infill- ASCE/SEI 41) and model IIC (strut
infill-Soft storey- ASCE/SEI 41). Three dimensional pushover
analyses have been carried out using SAP2000 software
incorporating inelastic material behavior for concrete, steel and infill
walls. Infill wall has been modeled as equivalent strut according to
suggested equation matching field test measurements and to the
ASCE/SEI 41 equation. The effect of building modeling on the
performance point as well as capacity and demand spectra due to EQ
design spectrum function in Madinah area has been investigated. The
response modification factor (R) for the 5 story RC building is
evaluated from capacity and demand spectra (ATC-40) for the
studied models. The results are summarized and discussed.
Abstract: Early pre-code reinforced concrete structures present
undetermined resistance to earthquakes. This situation is particularly
unacceptable in the case of essential structures, such as healthcare
structures and pilgrims' houses. Amongst these, an existing old RC
building in Madinah city (KSA) is seismically evaluated with and
without infill wall and their dynamic characteristics are compared
with measured values in the field using ambient vibration
measurements (AVM). After updating the mathematical models for
this building with the experimental results, three dimensional
pushover analysis (Nonlinear static analysis) was carried out using
commercial structural analysis software incorporating inelastic
material properties for concrete, infill and steel. The purpose of this
analysis is to evaluate the expected performance of structural systems
by estimating, strength and deformation demands in design, and
comparing these demands to available capacities at the performance
levels of interest. The results summarized and discussed.
Abstract: A capacity spectrum method (CSM), one of methodologies to evaluate seismic fragilities of building structures, has been long recognized as the most convenient method, even if it contains several limitations to predict the seismic response of structures of interest. This paper proposes the procedure to estimate seismic fragility curves using an incremental dynamic analysis (IDA) rather than the method adopting a CSM. To achieve the research purpose, this study compares the seismic fragility curves of a 5-story reinforced concrete (RC) moment frame obtained from both methods; an IDA method and aCSM. Both seismic fragility curves are similar in slight and moderate damage states whereas the fragility curve obtained from the IDA method presents less variation (or uncertainties) in extensive and complete damage states. This is due to the fact that the IDA method can properly capture the structural response beyond yielding rather than the CSM and can directly calculate higher mode effects. From these observations, the CSM could overestimate seismic vulnerabilities of the studied structure in extensive or complete damage states.
Abstract: The paper presents a plastic analysis procedure based
on the energy balance concept for performance based seismic retrofit
of multi-story multi-bay masonry infilled reinforced concrete (R/C)
frames with a ‘soft’ ground story using passive energy dissipation
(PED) devices with the objective of achieving a target performance
level of the retrofitted R/C frame for a given seismic hazard level at
the building site. The proposed energy based plastic analysis
procedure was employed for developing performance based design
(PBD) formulations for PED devices for a simulated application in
seismic retrofit of existing frame structures designed in compliance
with the prevalent standard codes of practice. The PBD formulations
developed for PED devices were implemented for simulated seismic
retrofit of a representative code-compliant masonry infilled R/C
frame with a ‘soft’ ground story using friction dampers as the PED
device. Non-linear dynamic analyses of the retrofitted masonry
infilled R/C frames is performed to investigate the efficacy and
accuracy of the proposed energy based plastic analysis procedure in
achieving the target performance level under design level
earthquakes. Results of non-linear dynamic analyses demonstrate that
the maximum inter-story drifts in the masonry infilled R/C frames
with a ‘soft’ ground story that is retrofitted with the friction dampers
designed using the proposed PBD formulations are controlled within
the target drifts under near-field as well far-field earthquakes.
Abstract: A key issue in seismic risk analysis within the context
of Performance-Based Earthquake Engineering is the evaluation of
the expected seismic damage of structures under a specific
earthquake ground motion. The assessment of the seismic
performance strongly depends on the choice of the seismic Intensity
Measure (IM), which quantifies the characteristics of a ground
motion that are important to the nonlinear structural response. Several
conventional IMs of ground motion have been used to estimate their
damage potential to structures. Yet, none of them has been proved to
be able to predict adequately the seismic damage. Therefore,
alternative, scalar intensity measures, which take into account not
only ground motion characteristics but also structural information
have been proposed. Some of these IMs are based on integration of
spectral values over a range of periods, in an attempt to account for
the information that the shape of the acceleration, velocity or
displacement spectrum provides. The adequacy of a number of these
IMs in predicting the structural damage of 3D R/C buildings is
investigated in the present paper. The investigated IMs, some of
which are structure specific and some are non structure-specific, are
defined via integration of spectral values. To achieve this purpose
three symmetric in plan R/C buildings are studied. The buildings are
subjected to 59 bidirectional earthquake ground motions. The two
horizontal accelerograms of each ground motion are applied along
the structural axes. The response is determined by nonlinear time
history analysis. The structural damage is expressed in terms of the
maximum interstory drift as well as the overall structural damage
index. The values of the aforementioned seismic damage measures
are correlated with seven scalar ground motion IMs. The comparative
assessment of the results revealed that the structure-specific IMs
present higher correlation with the seismic damage of the three
buildings. However, the adequacy of the IMs for estimation of the
structural damage depends on the response parameter adopted.
Furthermore, it was confirmed that the widely used spectral
acceleration at the fundamental period of the structure is a good
indicator of the expected earthquake damage level.
Abstract: Currently, seismic probabilistic risk assessments
(SPRA) for nuclear facilities use In-Structure Response Spectra
(ISRS) in the calculation of fragilities for systems and components.
ISRS are calculated via dynamic analyses of the host building
subjected to two orthogonal components of horizontal ground
motion. Each component is defined as the median motion in any
horizontal direction. Structural engineers applied the components
along selected X and Y Cartesian axes. The ISRS at different
locations in the building are also calculated in the X and Y directions.
The choice of the directions of X and Y are not specified by the
ground motion model with respect to geographic coordinates, and are
rather arbitrarily selected by the structural engineer. Normally, X and
Y coincide with the “principal” axes of the building, in the
understanding that this practice is generally conservative. For SPRA
purposes, however, it is desirable to remove any conservatism in the
estimates of median ISRS. This paper examines the effects of the
direction of horizontal seismic motion on the ISRS on typical nuclear
structure. We also evaluate the variability of ISRS calculated along
different horizontal directions. Our results indicate that some central
measures of the ISRS provide robust estimates that are practically
independent of the selection of the directions of the horizontal
Cartesian axes.
Abstract: Predicting earthquakes is an important issue in the
study of geography. Accurate prediction of earthquakes can help
people to take effective measures to minimize the loss of personal
and economic damage, such as large casualties, destruction of
buildings and broken of traffic, occurred within a few seconds.
United States Geological Survey (USGS) science organization
provides reliable scientific information about Earthquake Existed
throughout history & the Preliminary database from the National
Center Earthquake Information (NEIC) show some useful factors to
predict an earthquake in a seismic area like Aleutian Arc in the U.S.
state of Alaska. The main advantage of this prediction method that it
does not require any assumption, it makes prediction according to the
future evolution of the object's time series. The article compares
between simulation data result from trained BP and RBF neural
network versus actual output result from the system calculations.
Therefore, this article focuses on analysis of data relating to real
earthquakes. Evaluation results show better accuracy and higher
speed by using radial basis functions (RBF) neural network.
Abstract: Using ETABS software, this study analyzed 23
buildings to evaluate effects of mistakes during construction phase on
buildings structural behavior. For modelling, two different loadings
were assumed: 1) design loading and 2) loading due to the effects of
mistakes in construction phase. Research results determined that
considering traditional construction methods for buildings resulted in
a significant increase in dead loads and consequently intensified the
displacements and base-shears of buildings under seismic loads.
Abstract: South Africa has some regions which are susceptible
to moderate seismic activity. A peak ground acceleration of between
0.1g and 0.15g can be expected in the southern parts of the Western
Cape. Unreinforced Masonry (URM) is commonly used as a
construction material for 2 to 5 storey buildings in underprivileged
areas in and around Cape Town. URM is typically regarded as the
material most vulnerable to damage when subjected to earthquake
excitation. In this study, a three-storey URM building was analysed
by applying seven earthquake time-histories, which can be expected
to occur in South Africa using a finite element approach.
Experimental data was used to calibrate the in- and out-of-plane
stiffness of the URM. The results indicated that tensile cracking of
the in-plane piers was the dominant failure mode. It is concluded that
URM buildings of this type are at risk of failure especially if
sufficient ductility is not provided. The results also showed that
connection failure must be investigated further.
Abstract: Recently, there have been a lot of earthquakes in Japan.
It is necessary to promote seismic isolation devices for buildings. The
devices have been hardly diffused in attached houses, because the
devices are very expensive. We should develop a low-cost seismic
isolation device for detached houses. We suggested a new seismic
isolation device which uses a two-layer circular tube as a unit. If
hysteresis is produced in the two-layer circular tube under lateral
compression load, we think that the two-layer circular tube can have
energy absorbing capacity. It is necessary to contact the outer layer
and the inner layer to produce hysteresis. We have previously reported
how the inner layer comes in contact with the outer layer from a
perspective of analysis used mechanics of materials. We have clarified
that the inner layer comes in contact with the outer layer under a lateral
compression load. In this paper, we explored contact area between the
outer layer and the inner layer under a lateral compression load by
using FEA. We think that changing the inner layer’s thickness is
effective in increase the contact area. In order to change the inner
layer’s thickness, we changed the shape of the inner layer. As a result,
the contact area changes depending on the inner layer’s thickness.
Additionally, we experimented to check whether hysteresis occurs in
fact. As a consequence, we can reveal hysteresis in the two-layer
circular tube under the condition.
Abstract: This study has been presented which is a detailed
work of seismic microzonation of the city center. For seismic
microzonation area of 225 km2 has been selected as the study area.
MASW (Multichannel analysis of surface wave) and seismic
refraction methods have been used to generate one-dimensional shear
wave velocity profile at 250 locations and two-dimensional profile at
60 locations. These shear wave velocities are used to estimate
equivalent shear wave velocity in the study area at every 2 and 5 m
intervals up to a depth of 60 m. Levels of equivalent shear wave
velocity of soil are used the classified of the study area. After the
results of the study, it must be considered as components of urban
planning and building design of Denizli and the application and use
of these results should be required and enforced by municipal
authorities.
Abstract: The study area is Zaria, located in the basement
complex of northern Nigeria. The rock type forming the major part of
the Zaria batholith is granite. This research work was carried out to
compare the responses of seismic refraction tomography and
resistivity tomography in the same geologic environment and under
the same conditions. Hence, the choice of the site that has a visible
granitic outcrop that extends across a narrow stream channel and is
flanked by unconsolidated overburden, a neutral profile that was
covered by plain overburden and a site with thick lateritic cover
became necessary. The results of the seismic and resistivity
tomography models reveals that seismic velocity and resistivity does
not always simultaneously increase with depth, but their responses in
any geologic environment are determined by changes in the
mechanical and chemical content of the rock types rather than depth.
Abstract: High resolution seismic reflection has recently been carried out on Zaria batholith, with the aim of characterizing the granitic Zaria batholiths in terms of its lithology. The geology of the area has revealed that the older granite outcrops in the vicinity of Zaria are exposures of a syntectonics to late-tectonic granite batholiths which intruded a crystalline gneissic basement during the Pan-African Orogeny. During the data acquisition the geophone were placed at interval of 1 m, variable offset of 1 and 10 m was used. The common midpoint (CMP) method with 12 fold coverage was employed for the survey. Analysis of the generated 3D surface of the p wave velocities from different profiles for densities and bulk modulus revealed that the rock material is more consolidated in South East part of the batholith and less consolidated in the North Western part. This was in conformity with earlier identified geology of the area, with the South Eastern part majorly of granitic outcrop, while the North Western part is characterized with the exposure of gneisses and thick overburden cover. The difference in lithology was also confirmed by the difference in seismic sections and Arial satellite photograph. Hence two major lithologies were identified, the granitic and gneisses complex which are characterized by gradational boundaries.
Abstract: Tsunami early detection and warning systems have proved to be of ultimate importance, especially after the destructive tsunami that hit Japan in March 2012. Such systems are crucial to inform the authorities of any risk of a tsunami and of the degree of its danger in order to make the right decision and notify the public of the actions they need to take to save their lives. The purpose of this research is to enhance existing tsunami detection and warning systems. We first propose an automated and miniaturized model of an early tsunami detection and warning system. The model for the operation of a tsunami warning system is simulated using the data acquisition toolbox of Matlab and measurements acquired from specified internet pages due to the lack of the required real-life sensors, both seismic and hydrologic, and building a graphical user interface for the system. In the second phase of this work, we implement various satellite image filtering schemes to enhance the acquired synthetic aperture radar images of the tsunami affected region that are masked by speckle noise. This enables us to conduct a post-tsunami damage extent study and calculate the percentage damage. We conclude by proposing improvements to the existing telecommunication infrastructure of existing warning tsunami systems using a migration to IP-based networks and fiber optics links.
Abstract: There are several types of metal-based devices conceived as dampers for the seismic energy absorber whereby damages to the major structural components could be minimized for both new and existing structures. This paper aimed to develop and evaluate structural performance of slit circular shear panel damper for passive seismic energy protection by inelastic deformation. Structural evaluation was done using commercially available nonlinear FE simulation program. The main parameters considered are: diameter-to-thickness (D/t) ratio and slit length-to-width ratio (l/w). Depending on these parameters three different buckling mode and hysteretic behavior was found: yielding prior to buckling without strength degradation, yielding prior to buckling with strength degradation and yielding with buckling and strength degradation which forms pinching at initial displacement. The susceptible location at which the possible crack is initiated is also identified for selected specimens using rupture index.
Abstract: Seismic design criteria based on performance of
structures have recently been adopted by practicing engineers in
response to destructive earthquakes. A simple but efficient
structural-analysis tool capable of predicting both the strength and
ductility is needed to analyze reinforced concrete (RC) structures
under such event. A three-dimensional lattice model is developed in
this study to analyze torsions in high-strength RC members.
Optimization techniques for determining optimal variables in each
lattice model are introduced. Pure torsion tests of RC members are
performed to validate the proposed model. Correlation studies
between the numerical and experimental results confirm that the
proposed model is well capable of representing salient features of the
experimental results.
Abstract: The idea of adding metallic energy dissipaters to a structure to absorb a large part of the seismic energy began four decades ago. There are several types of metal-based devices conceived as dampers for the seismic energy absorber whereby damages to the major structural components could be minimized for both new and existing structures. This paper aimed to develop and evaluate structural performance of both stiffened and non stiffened circular shear panel damper for passive seismic energy protection by inelastic deformation. Structural evaluation was done using commercially available nonlinear FE simulation program. Diameter-to-thickness ratio is employed as main parameter to investigate the hysteresis performance of stiffened and unstiffened circular shear panel. Depending on these parameters three different buckling mode and hysteretic behavior was found: yielding prior to buckling without strength degradation, yielding prior to buckling with strength degradation and yielding with buckling and strength degradation which forms pinching at initial displacement. Hence, the hysteresis behavior is identified, specimens which deform without strength degradation so it will be used as passive energy dissipating device in civil engineering structures.
Abstract: Performance based design (PBD) is an iterative exercise in which a preliminary trial design of the building structure is selected and if the selected trial design of the building structure does not conform to the desired performance objective, the trial design is revised. In this context, development of a fundamental approach for performance based seismic design of masonry infilled frames with minimum number of trials is an important objective. The paper presents a plastic design procedure based on the energy balance concept for PBD of multi-story multi-bay masonry infilled reinforced concrete (R/C) frames subjected to near-field earthquakes. The proposed energy based plastic design procedure was implemented for trial performance based seismic design of representative masonry infilled reinforced concrete frames with various practically relevant distributions of masonry infill panels over the frame elevation. Non-linear dynamic analyses of the trial PBD of masonry infilled R/C frames was performed under the action of near-field earthquake ground motions. The results of non-linear dynamic analyses demonstrate that the proposed energy method is effective for performance based design of masonry infilled R/C frames under near-field as well as far-field earthquakes.