Abstract: Before designing an electrical system, the estimation of load is necessary for unit sizing and demand-generation balancing. The system could be a stand-alone system for a village or grid connected or integrated renewable energy to grid connection, especially as there are non–electrified villages in developing countries. In the classical model, the energy demand was found by estimating the household appliances multiplied with the amount of their rating and the duration of their operation, but in this paper, information exists for electrified villages could be used to predict the demand, as villages almost have the same life style. This paper describes a method used to predict the average energy consumed in each two months for every consumer living in a village by Artificial Neural Network (ANN). The input data are collected using a regional survey for samples of consumers representing typical types of different living, household appliances and energy consumption by a list of information, and the output data are collected from administration office of Piramagrun for each corresponding consumer. The result of this study shows that the average demand for different consumers from four villages in different months throughout the year is approximately 12 kWh/day, this model estimates the average demand/day for every consumer with a mean absolute percent error of 11.8%, and MathWorks software package MATLAB version 7.6.0 that contains and facilitate Neural Network Toolbox was used.
Abstract: Upgrading the thermal performance of building
envelope of existing residential buildings is an effective way to reduce
heat gain or heat loss. Overhang device is a common solution for
building envelope improvement as it can cut down solar heat gain and
thereby can reduce the energy used for space cooling in summer time.
Despite that, overhang can increase the demand for indoor heating in
winter due to its function of lowering the solar heat gain. Obviously,
overhang has different impacts on energy use in different climatic
zones which have different energy demand. To evaluate the impact of
overhang device on building energy performance under different
climates of China, an energy analysis model is built up in a
computer-based simulation program known as DesignBuilder based
on the data of a typical high-rise residential building. The energy
simulation results show that single overhang is able to cut down
around 5% of the energy consumption of the case building in the
stand-alone situation or about 2% when the building is surrounded by
other buildings in regions which predominantly rely on space cooling
though it has no contribution to energy reduction in cold region. In
regions with cold summer and cold winter, adding overhang over
windows can cut down around 4% and 1.8% energy use with and
without adjoining buildings, respectively. The results indicate that
overhang might not an effective shading device to reduce the energy
consumption in the mixed climate or cold regions.
Abstract: This research investigates cluster development in the area called the Greater Mekong Subregion (GMS), which consists of Thailand, the People’s Republic of China (PRC), the Yunnan Province and Guangxi Zhuang Autonomous Region, Myanmar, the Lao People’s Democratic Republic (Lao PDR), Cambodia, and Vietnam. The study utilized Porter’s competitiveness theory and the cluster mapping approach to analyze the competitiveness of the region. The data collection consists of interviews, focus groups, and the analysis of secondary data. The findings identify some evidence of cluster development in the GMS; however, there is no clear indication of collaboration among the components in the clusters. GMS clusters tend to be stand-alone. The clusters in Vietnam, Lao PDR, Myanmar, and Cambodia tend to be labor intensive, whereas the clusters in Thailand and the PRC (Yunnan) have the potential to successfully develop into innovative clusters. The collaboration and integration among the clusters in the GMS area are promising, though it could take a long time. The most likely relationship between the GMS countries could be, for example, suppliers of the low-end, labor-intensive products will be located in the low income countries such as Myanmar, Lao PDR, and Cambodia, and these countries will be providing input materials for innovative clusters in the middle income countries such as Thailand and the PRC.
Abstract: The study assessed the potential and economic viability of stand-alone wind systems for embedded generation, taking into account its benefits to small off-grid rural communities at 40 meteorological sites in Nigeria. A specific electric load profile was developed to accommodate communities consisting of 200 homes, a school and a community health centre. This load profile was incorporated within the distributed generation analysis producing energy in the MW range, while optimally meeting daily load demand for the rural communities. Twenty-four years (1987 to 2010) of wind speed data at a height of 10m utilized for the study were sourced from the Nigeria Meteorological Department, Oshodi. The HOMER® software optimizing tool was engaged for the feasibility study and design. Each site was suited to 3MW wind turbines in sets of five, thus 15MW was designed for each site. This design configuration was adopted in order to easily compare the distributed generation system amongst the sites to determine their relative economic viability in terms of life cycle cost, as well as levelised cost of producing energy. A net present value was estimated in terms of life cycle cost for 25 of the 40 meteorological sites. On the other hand, the remaining sites yielded a net present cost; meaning the installations at these locations were not economically viable when utilizing the present tariff regime for embedded generation in Nigeria.
Abstract: To provide an efficient solar generation system, the embodiment design of a two axis solar tracker for an array of photovoltaic (PV) panels destiny to supply the power demand on off-the-grid areas was developed. Photovoltaic cells have high costs in relation to t low efficiency; and while a lot of research and investment has been made to increases its efficiency a few points, there is a profitable solution that increases by 30-40% the annual power production: two axis solar trackers. A solar tracker is a device that supports a load in a perpendicular position toward the sun during daylight. Mounted on solar trackers, the solar panels remain perpendicular to the incoming sunlight at day and seasons so the maximum amount of energy is outputted. Through a preview research done it was justified why the generation of solar energy through photovoltaic panels mounted on dual axis structures is an attractive solution to bring electricity to remote off-the-grid areas. The work results are the embodiment design of an azimuth-altitude solar tracker to guide an array of photovoltaic panels based on a specific design methodology. The designed solar tracker is mounted on a pedestal that uses two slewing drives‚ with a nominal torque of 1950 Nm‚ to move a solar array that provides 3720 W from 12 PV panels.
Abstract: Maintenance management is no longer a stand-alone activity. It has now assumed a strategic position in many organisations that have recognised its importance in achieving primary goals and a key aspect of effective management of facilities. This paper aims at providing an understanding of the role and function of strategic management in creating and sustaining an effective maintenance management system in an organisation. The background provides an articulated concept and principles of strategic management. The theoretical concepts paved way for a conceptual framework for which strategic management can be integrated into the maintenance management system of an organisation to improve effectiveness in the maintenance of facilities.
Abstract: From a theoretical perspective, electric buses can be more sustainable and can be cheaper than fossil fuelled buses in city traffic. The authors have not found other studies based on actual urban public transport in Swedish winter climate. Further on, noise measurements from buses for the European market were found old. The aims of this follow-up study was therefore to test and possibly verify in a real-life environment how energy efficient and silent electric buses are, and then conclude on if electric buses are preferable to use in public transport. The Ebusco 2.0 electric bus, fitted with a 311 kWh battery pack, was used and the tests were carried out during November 2014-April 2015 in eight municipalities in the south of Sweden. Six tests took place in urban traffic and two took place in more of a rural traffic setting. The energy use for propulsion was measured via logging of the internal system in the bus and via an external charging meter. The average energy use turned out to be 8% less (0,96 kWh/km) than assumed in the earlier theoretical study. This rate allows for a 320 km range in public urban traffic. The interior of the bus was kept warm by a diesel heater (biodiesel will probably be used in a future operational traffic situation), which used 0,67 kWh/km in January. This verified that electric buses can be up to 25% cheaper when used in public transport in cities for about eight years. The noise was found to be lower, primarily during acceleration, than for buses with combustion engines in urban bus traffic. According to our surveys, most passengers and drivers appreciated the silent and comfortable ride and preferred electric buses rather than combustion engine buses. Bus operators and passenger transport executives were also positive to start using electric buses for public transport. The operators did however point out that procurement processes need to account for eventual risks regarding this new technology, along with personnel education. The study revealed that it is possible to establish a charging infrastructure for almost all studied bus lines. However, design of a charging infrastructure for each municipality requires further investigations, including electric grid capacity analysis, smart location of charging points, and tailored schedules to allow fast charging. In conclusion, electric buses proved to be a preferable alternative for all stakeholders involved in public bus transport in the studied municipalities. However, in order to electric buses to be a prominent support for sustainable development, they need to be charged either by stand-alone units or via an expansion of the electric grid, and the electricity should be made from new renewable sources.
Abstract: Green and renewable energy is getting extraordinary
consideration today, because of ecological concerns made by blazing
of fossil powers. Photovoltaic and wind power generation are the
basic decisions for delivering power in this respects. Producing
power by the sun based photovoltaic systems is known to the world,
yet control makers may get confounded to pick between on-grid and
off-grid systems. In this exploration work, an endeavor is made to
compare the off-grid (stand-alone) and on-grid (grid-connected)
frameworks. The work presents relative examination, between two
distinctive PV frameworks situated at V.V.P. Engineering College,
Rajkot. The first framework is 100 kW remain solitary and the
second is 60 kW network joined. The real-time parameters compared
are; output voltage, load current, power in-flow, power output,
performance ratio, yield factor, and capacity factor. The voltage
changes and the power variances in both frameworks are given
exceptional consideration and the examination is made between the
two frameworks to judge the focal points and confinements of both
the frameworks.
Abstract: The photovoltaic (PV) panel with no galvanic
isolation system is well known technique in the world which is
effective and delivers power with enhanced efficiency. The PV
generation presented here is for stand-alone system installed in
remote areas when as the resulting power gets connected to electronic
load installation instead of being tied to the grid. Though very small,
even then transformer-less topology is shown to be with leakage in
pico-ampere range. By using PWM technique PWM, leakage current
in different situations is shown. The results shown in this paper show
how the pico-ampere current is reduced to femto-ampere through use
of inductors and capacitors of suitable values of inductor and
capacitors with the load.
Abstract: This paper introduces a method to optimal design of a
hybrid Wind/Photovoltaic/Fuel cell generation system for a typical
domestic load that is not located near the electricity grid. In this
configuration the combination of a battery, an electrolyser, and a
hydrogen storage tank are used as the energy storage system. The aim
of this design is minimization of overall cost of generation scheme
over 20 years of operation. The Matlab/Simulink is applied for
choosing the appropriate structure and the optimization of system
sizing. A teaching learning based optimization is used to optimize the
cost function. An overall power management strategy is designed for
the proposed system to manage power flows among the different
energy sources and the storage unit in the system. The results have
been analyzed in terms of technical and economic. The simulation
results indicate that the proposed hybrid system would be a feasible
solution for stand-alone applications at remote locations.
Abstract: In this communication, a low-cost circularly
polarized wire antenna exhibiting improved gain performance for
Dedicated Short Range Communications (DSRC), vehicle-to-vehicle
(V2V) and vehicle-to-infrastructure (V2I) communications is
presented. The proposed antenna comprises a Y-shaped quarterwavelength
monopole antenna surrounded by two iterations of eight
conductive arched walls acting as parasitic elements to enhance the
overall antenna gain and to shape the radiation pattern in the H-plane.
A hemispherical radome shell is added to protect the antenna
structure and its effect on the antenna performance is discussed. The
designed antenna demonstrates antenna gain of 8.2 dB with
omnidirectional far-field radiation pattern in the H-plane. The gain of
the proposed antenna is also compared with the characteristic of the
stand-alone Y-shaped monopole to highlight the advantages of the
proposed approach.
Abstract: Batteries of electric vehicles (BEV) are becoming
more attractive with the advancement of new battery technologies
and promotion of electric vehicles. BEV batteries are recharged on
board vehicles using either the grid (G2V for Grid to Vehicle) or
renewable energies in a stand-alone application (H2V for Home to
Vehicle). This paper deals with the modeling, sizing and control of a
photovoltaic stand-alone application that can charge the BEV at
home. The modeling approach and developed mathematical models
describing the system components are detailed. Simulation and
experimental results are presented and commented.
Abstract: In this study, we aim to demonstrate a microgrid
system experimental simulation for an easy understanding of a
large-scale microgrid system. This model is required for industrial
training and learning environments. However, in order to create an
exact representation of a microgrid system, the laboratory-scale
system must fulfill the requirements of a grid-connected inverter, in
which power values are assigned to the system to cope with the
intermittent output from renewable energy sources. Aside from that,
during fluctuations in load capacity, the grid-connected system must
be able to supply power from the utility grid side and microgrid side in
a balanced manner. Therefore, droop control is installed in the
inverter’s control board to maintain a balanced power sharing in both
sides. This power control in a stand-alone condition and droop control
in a grid-connected condition must be implemented in order to
maintain a stabilized system. Based on the experimental results, power
control and droop control can both be applied in the system by
comparing the experimental and reference values.
Abstract: This paper presents a simulation and mathematical model of stand-alone solar-wind-diesel based hybrid energy system (HES). A power management system is designed for multiple energy resources in a stand-alone hybrid energy system. Both Solar photovoltaic and wind energy conversion system consists of maximum power point tracking (MPPT), voltage regulation, and basic power electronic interfaces. An additional diesel generator is included to support and improve the reliability of stand-alone system when renewable energy sources are not available. A power management strategy is introduced to distribute the generated power among resistive load banks. The frequency regulation is developed with conventional phase locked loop (PLL) system. The power management algorithm was applied in Matlab®/Simulink® to simulate the results.
Abstract: Distributed generation units (DGs) are grid-connected or stand-alone electric generation units located within the electric distribution system at or near the end user. It is generally accepted that centralized electric power plants will remain the major source of the electric power supply for the near future. DGs, however, can complement central power by providing incremental capacity to the utility grid or to an end user. This paper presents an efficient power dispatching model for hybrid wind-Solar power generation system, to satisfy some essential requirements, such as dispersed electric power demand, electric power quality and reducing generation cost and so on. In this paper, presented some elements of the main parts in the hybrid system; and then made fundamental dispatching strategies according to different situations; then pointed out four improving measures to improve genetic algorithm, such as: modify the producing way of selection probability, improve the way of crossover, protect excellent chromosomes, and change mutation range and so on. Finally, propose a technique for solving the unit's commitment for dispatching problem based on an improved genetic algorithm.
Abstract: Emission regulations for diesel engines are being strengthened and it is impossible to meet the standards without exhaust after-treatment systems. Lack of the space in many diesel vehicles, however, make it difficult to design and install stand-alone catalytic converters such as DOC, DPF, and SCR in the vehicle exhaust systems. Accordingly, those have been installed inside the muffler to save the space, and referred to the catalytic muffler. However, that has complex internal structure with perforated plate and pipe for noise and monolithic catalyst for emission reduction. For this reason, flow uniformity and pressure drop, which affect efficiency of catalyst and engine performance, respectively, should be examined when the catalytic muffler is designed. In this work, therefore, the flow uniformity and pressure drop to improve the performance of the catalytic converter and the engine have been numerically investigated by changing various design parameters such as inlet shape, porosity, and outlet shape of the muffler using the three-dimensional turbulent flow of the incompressible, non-reacting, and steady state inside the catalytic muffler. Finally, it can be found that the shape, in which the muffler has perforated pipe inside the inlet part, has higher uniformity index and lower pressure drop than others considered in this work.
Abstract: In this paper, the optimum design for renewable energy system powered an aquaculture pond was determined. Hybrid Optimization Model for Electric Renewable (HOMER) software program, which is developed by U.S National Renewable Energy Laboratory (NREL), is used for analyzing the feasibility of the stand alone and hybrid system in this study. HOMER program determines whether renewable energy resources satisfy hourly electric demand or not. The program calculates energy balance for every 8760 hours in a year to simulate operation of the system. This optimization compares the demand for the electrical energy for each hour of the year with the energy supplied by the system for that hour and calculates the relevant energy flow for each component in the model. The essential principle is to minimize the total system cost while HOMER ensures control of the system. Moreover the feasibility analysis of the energy system is also studied. Wind speed, solar irradiance, interest rate and capacity shortage are the parameters which are taken into consideration. The simulation results indicate that the hybrid system is the best choice in this study, yielding lower net present cost. Thus, it provides higher system performance than PV or wind stand alone systems.
Abstract: The research describes the implementation of a novel and stand-alone system for dynamic hazard warning. The system uses all existing infrastructure already in place like mobile networks, a laptop/PC and the small installation software. The geospatial dataset are the maps of a region which are again frugal. Hence there is no need to invest and it reaches everyone with a mobile. A novel architecture of hazard assessment and warning introduced where major technologies in ICT interfaced to give a unique WebGIS based dynamic real time geohazard warning communication system. A never before architecture introduced for integrating WebGIS with telecommunication technology. Existing technologies interfaced in a novel architectural design to address a neglected domain in a way never done before – through dynamically updatable WebGIS based warning communication. The work publishes new architecture and novelty in addressing hazard warning techniques in sustainable way and user friendly manner. Coupling of hazard zonation and hazard warning procedures into a single system has been shown. Generalized architecture for deciphering a range of geo-hazards has been developed. Hence the developmental work presented here can be summarized as the development of internet-SMS based automated geo-hazard warning communication system; integrating a warning communication system with a hazard evaluation system; interfacing different open-source technologies towards design and development of a warning system; modularization of different technologies towards development of a warning communication system; automated data creation, transformation and dissemination over different interfaces. The architecture of the developed warning system has been functionally automated as well as generalized enough that can be used for any hazard and setup requirement has been kept to a minimum.
Abstract: Standalone micro-hydrokinetic river (MHR) system is
one of the promising technologies to be used for remote rural
electrification. It simply requires the flow of water instead of
elevation or head, leading to expensive civil works. This paper
demonstrates an economic benefit offered by a standalone MHR
system when compared to the commonly used standalone systems
such as solar, wind and diesel generator (DG) at the selected study
site in Kwazulu Natal. Wind speed and solar radiation data of the
selected rural site have been taken from national aeronautics and
space administration (NASA) surface meteorology database. The
hybrid optimization model for electric renewable (HOMER) software
was used to determine the most feasible solution when using MHR,
solar, wind or DG system to supply 5 rural houses. MHR system
proved to be the best cost-effective option to consider at the study site
due to its low cost of energy (COE) and low net present cost (NPC).
Abstract: In IETF RFC 2002, Mobile-IP was developed to
enable Laptobs to maintain Internet connectivity while moving
between subnets. However, the packet loss that comes from
switching subnets arises because network connectivity is lost while
the mobile host registers with the foreign agent and this encounters
large end-to-end packet delays. The criterion to initiate a simple and
fast full-duplex connection between the home agent and foreign
agent, to reduce the roaming duration, is a very important issue to be
considered by a work in this paper. State-transition Petri-Nets of the
modeling scenario-based CIA: communication inter-agents procedure
as an extension to the basic Mobile-IP registration process was
designed and manipulated to describe the system in discrete events.
The heuristic of configuration file during practical Setup session for
registration parameters, on Cisco platform Router-1760 using IOS
12.3 (15)T and TFTP server S/W is created. Finally, stand-alone
performance simulations from Simulink Matlab, within each subnet
and also between subnets, are illustrated for reporting better end-toend
packet delays. Results verified the effectiveness of our Mathcad
analytical manipulation and experimental implementation. It showed
lower values of end-to-end packet delay for Mobile-IP using CIA
procedure-based early registration. Furthermore, it reported packets
flow between subnets to improve losses between subnets.