Abstract: This paper introduces selected composition of conventional concretes and their resulting mechanical properties at different ages of concrete. With respect to utilization of mineral admixtures, fly ash and ground limestone agents were included in addition to pure Portland binder. The proposal of concrete composition remained constant in basic concrete components such as cement and representation of individual contents of aggregate fractions; weight dosing of admixtures and water dose were only modified. Water dose was chosen in order to achieve identical consistence by settlement for all proposals of concrete composition. Mechanical properties monitored include compression strength, static and dynamic modulus of concrete elasticity, at ages of 7, 28, 90, and 180 days.
Abstract: An important aspect of planning for shallow tunneling under urban areas is the determination of likely surface movements and interaction with existing structures. Back analysis of built tunnels that their settlements magnitude is available, could aid the designers to have a more accuracy in future projects.
In this paper, one single Tehran Metro Tunnel (at west of Hor square, Jang University Street) was selected. At first, surface settlements of this tunnel were measured in situ. Then this tunnel was modeled using the commercial finite deference software FLAC-3D. Finally, Results of modeling and in situ measurements compared for verification.
Abstract: At highly congested reinforcement regions, which is common at beam-column joint area, clear spacing between parallel bars becomes less than maximum normal aggregate size (20mm) which has not been addressed in any design code and specifications. Limited clear spacing between parallel bars (herein after thin cover) is one of the causes which affect anchorage performance. In this study, an experimental investigation was carried out to understand anchorage performance of reinforcement in Self-Compacting Concrete (SCC) and Normal Concrete (NC) at highly congested regions under uni-axial tensile loading. Column bar was pullout whereas; beam bars were offset from column reinforcement creating thin cover as per site condition. Two different sizes of coarse aggregate were used for NC (20mm and 10mm). Strain gauges were also installed along the bar in some specimens to understand the internal stress mechanism. Test results reveal that anchorage performance is affected at highly congested reinforcement region in NC with maximum aggregate size 20mm whereas; SCC and Small Aggregate (10mm) gives better structural performance.
Abstract: A total of fourteen slab-edge beam-column connection specimens were tested gradually to failure under the effect of simultaneous action of shear force and moment. The objective was to investigate the influence of some parameters thought to be important on the behavior and strength of slab-column connections with edge beams encountered in flat slab flooring and roofing systems. The parameters included the existence and strength of edge beam, depth and width of edge beam, steel reinforcement ratio of slab, ratio of moment to shear force, and the existence of openings in the region next to the column.
Results obtained demonstrated the importance of the studied parameters on the strength and behavior of slab-column connections with edge beams.
Abstract: The objective of this research is to investigate the
advantages of using large-diameter 0.7 inch prestressing strands in
pretention applications. The advantages of large-diameter strands are
mainly beneficial in the heavy construction applications. Bridges and
tunnels are subjected to a higher daily traffic with an exponential
increase in trucks ultimate weight, which raise the demand for higher
structural capacity of bridges and tunnels. In this research, precast
prestressed I-girders were considered as a case study. Flexure
capacities of girders fabricated using 0.7 inch strands and different
concrete strengths were calculated and compared to capacities of 0.6
inch strands girders fabricated using equivalent concrete strength.
The effect of bridge deck concrete strength on composite deck-girder
section capacity was investigated due to its possible effect on final
section capacity. Finally, a comparison was made to compare the
bridge cross-section of girders designed using regular 0.6 inch strands
and the large-diameter 0.7 inch. The research findings showed that
structural advantages of 0.7 inch strands allow for using fewer bridge
girders, reduced material quantity, and light-weight members. The
structural advantages of 0.7 inch strands are maximized when high
strength concrete (HSC) are used in girder fabrication, and concrete
of minimum 5ksi compressive strength is used in pouring bridge
decks. The use of 0.7 inch strands in bridge industry can partially
contribute to the improvement of bridge conditions, minimize
construction cost, and reduce the construction duration of the project.
Abstract: The National Bridge Inventory (NBI) includes more
than 600,000 bridges within the United States of America.
Prestressed concrete girder bridges represent one of the most widely
used bridge systems. The majority of these girder bridges were
constructed using 0.5 and 0.6 inch diameter strands. The main
impediments to using larger strand diameters are: 1) lack of prestress
bed capacities, 2) lack of structural knowledge regarding the transfer
and development length of larger strands, and 3) the possibility of
developing wider end zone cracks upon strand release.
This paper presents a study about using 0.7 inch strands in girder
fabrication. Transfer and development length were evaluated, and
girders were fabricated using 0.7 inch strands at different spacings.
Results showed that 0.7 inch strands can be used at 2.0 inch spacing
without violating the AASHTO LRFD Specifications, while attaining
superior performance in shear and flexure.
Abstract: Laser Profiler (LP) data from aerial laser surveys have
been increasingly used as topographical inputs to numerical
simulations of flooding and inundation in river basins. LP data has
great potential for reproducing topography, but its effective usage has
not yet been fully established. In this study, flooding and inundation
are simulated numerically using LP data for the Jobaru River basin of
Japan’s Saga Plain. The analysis shows that the topography is
reproduced satisfactorily in the computational domain with urban and
agricultural areas requiring different grid sizes. A 2-D numerical
simulation shows that flood flow behavior changes as grid size is
varied.
Abstract: This paper deals with behavior and capacity of
punching shear force for flat slabs produced from steel fiber
reinforced self compacting concrete (SFRSCC) by application
nonlinear finite element method. Nonlinear finite element analysis on
nine slab specimens was achieved by using ANSYS software. A
general description of the finite element method, theoretical modeling
of concrete and reinforcement are presented. The nonlinear finite
element analysis program ANSYS is utilized owing to its capabilities
to predict either the response of reinforced concrete slabs in the post
elastic range or the ultimate strength of a flat slabs produced from
steel fiber reinforced self compacting concrete (SFRSCC). In order to
verify the analytical model used in this research using test results of
the experimental data, the finite element analysis were performed
then a parametric study of the effect ratio of flexural reinforcement,
ratio of the upper reinforcement, and volume fraction of steel fibers
were investigated. A comparison between the experimental results
and those predicted by the existing models are presented. Results and
conclusions may be useful for designers, have been raised, and
represented.
Abstract: In the planning point of view, it is essential to have
mode choice, due to the massive amount of incurred in transportation
systems. The intercity travellers in Libya have distinct features, as
against travellers from other countries, which includes cultural and
socioeconomic factors. Consequently, the goal of this study is to
recognize the behavior of intercity travel using disaggregate models,
for projecting the demand of nation-level intercity travel in Libya.
Multinomial Logit Model for all the intercity trips has been
formulated to examine the national-level intercity transportation in
Libya. The Multinomial logit model was calibrated using nationwide
revealed preferences (RP) and stated preferences (SP) survey. The
model was developed for deference purpose of intercity trips (work,
social and recreational). The variables of the model have been
predicted based on maximum likelihood method. The data needed for
model development were obtained from all major intercity corridors
in Libya. The final sample size consisted of 1300 interviews. About
two-thirds of these data were used for model calibration, and the
remaining parts were used for model validation. This study, which is
the first of its kind in Libya, investigates the intercity traveler’s
mode-choice behavior. The intercity travel mode-choice model was
successfully calibrated and validated. The outcomes indicate that, the
overall model is effective and yields higher precision of estimation.
The proposed model is beneficial, due to the fact that, it is receptive
to a lot of variables, and can be employed to determine the impact of
modifications in the numerous characteristics on the need for various
travel modes. Estimations of the model might also be of valuable to
planners, who can estimate possibilities for various modes and
determine the impact of unique policy modifications on the need for
intercity travel.
Abstract: This paper in essence presents comparative
experimental data on the mechanical performance of steel and
synthetic fibre-reinforced concrete under compression, tensile split
and flexure. URW1050 steel fibre and HPP45 synthetic fibre, both
with the same concrete design mix, have been used to make cube
specimens for a compression test, cylinders for a tensile split test and
beam specimens for a flexural test. The experimental data
demonstrated steel fibre reinforced concrete to be stronger in flexure
at early stages, whilst both fibre reinforced concrete types displayed
comparatively the same performance in compression, tensile splitting
and 28-day flexural strength. In terms of post-crack controlHPP45
was preferable.
Abstract: Experimental study on the influence of fibre content
on crack behaviour and propagation in synthetic-fibre reinforced
beams has been reported in this paper. The tensile behaviour of
metallic fibre concrete is evaluated in terms of residual flexural
tensile strength values determined from the load-crack mouth
opening displacement curve or load-deflection curve obtained by
applying a centre-point load on a simply supported notched prism.
The results achieved demonstrate that an increase in fibre content has
an almost negligible effect on compressive and tensile splitting
properties, causes a marginal increment in flexural tensile strength
and increasesthe Re3 value.
Abstract: This paper investigates experimentally and
analytically the torsion behavior of steel fibered high strength self
compacting concrete beams reinforced by GFRP bars. Steel fibered
high strength self compacting concrete (SFHSSCC) and GFRP bars
became in the recent decades a very important materials in the
structural engineering field. The use of GFRP bars to replace steel
bars has emerged as one of the many techniques put forward to
enhance the corrosion resistance of reinforced concrete structures.
High strength concrete and GFRP bars attract designers and
architects as it allows improving the durability as well as the esthetics
of a construction. One of the trends in SFHSSCC structures is to
provide their ductile behavior and additional goal is to limit
development and propagation of macro-cracks in the body of
SFHSSCC elements. SFHSSCC and GFRP bars are tough, improve
the workability, enhance the corrosion resistance of reinforced
concrete structures, and demonstrate high residual strengths after
appearance of the first crack. Experimental studies were carried out
to select effective fiber contents. Three types of volume fraction from
hooked shape steel fibers are used in this study, the hooked steel
fibers were evaluated in volume fractions ranging between 0.0%,
0.75% and 1.5%. The beams shape is chosen to create the required
forces (i.e. torsion and bending moments simultaneously) on the test
zone. A total of seven beams were tested, classified into three groups.
All beams, have 200cm length, cross section of 10×20cm,
longitudinal bottom reinforcement of 3