Abstract: Particle swarm optimization (PSO) technique is applied to design the water distribution pipeline network. A simulation-optimization model is formulated with the objective of minimizing cost and is applied to a benchmark water distribution system optimization problem. The benchmark problem taken for the application of PSO technique to optimize the pipe size of the water distribution network is New York City water supply system problem. The results from the analysis infer that PSO is a potential alternative optimization technique when compared to other heuristic techniques for optimal sizing of water distribution systems.
Abstract: In the past, there were many bridge-s collapses due to
lack of bridge structural capacity information. Most of concrete
bridge health was relied on information from visual inspection, which
sometime was inadequate. This study was conducted in order to
investigate relationship between bridge structural condition and
bridge visual condition. This study was a part of a big project
conducted at Department of Highways of Thailand. In this study, 31
bridges including slab-type bridges, plank-girder bridges, prestressed
box-beam bridges, prestressed I-girder bridges and prestressed multibeam
bridges were selected for visual inspection and load test. It was
found a positive correlation between bridge appearance and bridge-s
load carrying capacity. However, statistical characteristic revealed
low correlation between them.
Abstract: Structural performance and seismic vulnerability of
masonry buildings in Algeria are investigated in this paper. Structural
classification of such buildings is carried out regarding their
structural elements. Seismicity of Algeria is briefly discussed. Then
vulnerability of masonry buildings and their failure mechanisms in
the Boumerdes earthquake (May, 2003) are examined.
Abstract: According to the Auckland climate, building passive
design more focus on improving winter indoor thermal and health
conditions. Based on field study data of indoor air temperature and
relative humidity close to ceiling and floor of an insulated Auckland
townhouse with and without a whole home mechanical ventilation
system, this study is to analysis variation of indoor microclimate data
of an Auckland townhouse using or not using the mechanical
ventilation system to evaluate winter indoor thermal and health
conditions for the future house design with a mechanical ventilation
system.
Abstract: The UK Government has emphasized the role of Local Authorities as a key player in its flagship residential energy efficiency strategies, by identifying and targeting areas for energy efficiency improvements. Residential energy consumption in England is characterized by significant geographical variation in energy demand, which makes centralized targeting of areas for energy efficiency intervention difficult. This paper draws on research which aims to understand how demographic, social, economic, urban form and climatic factors influence the geographical variations in English residential gas consumption. The paper reports the findings of a multiple regression model that shows how 64% of the geographical variation in residential gas consumption is accounted for by variations in these factors. Results from this study, after further refinement and validation, can be used by Local Authorities to identify areas within their boundaries that have higher than expected gas consumption, these may be prime targets for energy efficiency initiatives.
Abstract: Housing is a basic human right. The provision of new
house shall be free from any defects, even for the defects that people
do normally considered as 'cosmetic defects'. This paper studies
about the building defects of newly completed house of 72 unit of
double-storey terraced located in Bangi, Selangor. The building
survey implemented using protocol 1 (visual inspection). As for new
house, the survey work is very stringent in determining the defects
condition and priority. Survey and reporting procedure is carried out
based on CSP1 Matrix that involved scoring system, photographs and
plan tagging. The analysis is done using Statistical Package for Social
Sciences (SPSS). The finding reveals that there are 2119 defects
recorded in 72 terraced houses. The cumulative score obtained was
27644 while the overall rating is 13.05. These results indicate that the
construction quality of the newly terraced houses is low and not up to
an acceptable standard as the new house should be.