Abstract: This paper presents the analysis on the performance of monopole antenna with fluorescent tubes. In this research, the simulation and experimental approach is conducted. The fluorescent tube with different length and size is designed using Computer Simulation Technology (CST) software and the characteristics of antenna parameter are simulated throughout the software. CST was used to simulate antenna parameters such as return loss, resonant frequency, gain and directivity. Vector Network Analyzer (VNA) was used to measure the return loss of plasma antenna in order to validate the simulation results. In the simulation and experiment, the supply frequency is set starting from 1 GHz to 10 GHz. The results show that the return loss of plasma antenna changes when size of fluorescent tubes is varied, correspond to the different plasma properties. It shows that different values of plasma properties such as plasma frequency and collision frequency gives difference result of return loss, gain and directivity. For the gain, the values range from 2.14 dB to 2.36 dB. The return loss of plasma antenna offers higher value range from -22.187 dB to -32.903 dB. The higher the values of plasma frequency and collision frequency, the higher return loss can be obtained. The values obtained are comparative to the conventional type of metal antenna.
Abstract: Housing is a basic human right. The provision of new
house shall be free from any defects, even for the defects that people
do normally considered as 'cosmetic defects'. This paper studies
about the building defects of newly completed house of 72 unit of
double-storey terraced located in Bangi, Selangor. The building
survey implemented using protocol 1 (visual inspection). As for new
house, the survey work is very stringent in determining the defects
condition and priority. Survey and reporting procedure is carried out
based on CSP1 Matrix that involved scoring system, photographs and
plan tagging. The analysis is done using Statistical Package for Social
Sciences (SPSS). The finding reveals that there are 2119 defects
recorded in 72 terraced houses. The cumulative score obtained was
27644 while the overall rating is 13.05. These results indicate that the
construction quality of the newly terraced houses is low and not up to
an acceptable standard as the new house should be.