Abstract: In this paper, several different types of natural gas liquefaction cycle. First, two processes are a cascade process with two staged compression were designed and simulated. These include Inter-cooler which is consisted to Propane, Ethylene and Methane cycle, and also, liquid-gas heat exchanger is applied to between of methane and ethylene cycles (process2) and between of ethylene and propane (process2). Also, these cycles are compared with two staged cascade process using only a Inter-cooler (process1). The COP of process2 and process3 showed about 13.99% and 6.95% higher than process1, respectively. Also, the yield efficiency of LNG improved comparing with process1 by 13.99% lower specific power. Additionally, C3MR process are simulated and compared with Process 2.
Abstract: In this study, we experiment on precise control outlet
temperature of water from the water cooler with hot-gas bypass
method based on PI control logic for machine tool. Recently, technical
trend for machine tools is focused on enhancement of speed and
accuracy. High speedy processing causes thermal and structural
deformation of objects from the machine tools. Water cooler has to be
applied to machine tools to reduce the thermal negative influence with
accurate temperature controlling system. The goal of this study is to
minimize temperature error in steady state. In addition, control period
of an electronic expansion valve were considered to increment of
lifetime of the machine tools and quality of product with a water
cooler.