Abstract: In this article, Optimal Control for Coordinated Control (COC) of Series Vectorial Compensator (SVeC) and Power System Stabilizer (PSS) in order to damp Low Frequency Oscillations (LFO) is proposed. SVeC is a series Flexible Alternating Current Transmission System (FACTS) device. The Optimal Control strategy based on state feedback control for coordination of PSS and SVeC controllers under different loading conditions has not been developed. So, the Optimal State Feedback Controller (OSFC) for incorporating of PSS and SVeC controllers in COC manner has been developed in this paper. The performance of the proposed controller is checked through eigenvalue analysis and nonlinear time domain simulation results. The proposed Optimal Controller design for the COC of SVeC and PSS results will be analyzed without controller. The comparative results show that Optimal Controller for COC of SVeC and PSSs improve greatly the system damping LFO than without controller.
Abstract: A double module hollow fiber supported liquid
membrane (HFSLM) was applied to selectively separate lead and
mercury ions from dilute synthetic produced water. The experiments
were investigated on several variables: types of extractants
(D2EHPA, Cyanex 471, Aliquat 336, and TOA), concentration of the
selected extractant and operating time. The results clearly showed
that the double module HFSLM could selectively separate Pb(II) and
Hg(II) in feed solution at a very low concentration to less than the
regulatory discharge limit of 0.2 and 0.005 mg/L issued by the
Ministry of Industry and the Ministry of Natural Resource
Environment, Thailand. The highest extractions of lead and mercury
ions from synthetic produced water were 96% and 100% using 0.03
M D2EHPA and 0.06 M Aliquat 336 as the extractant for the first
and second modules.