Abstract: Magnetic signature detection provides sensitive detection of metal objects, especially in the natural environment. Our group is developing a tabletop setup for magnetic signatures of various small and model objects. A particular issue is the separation of permanent and induced magnetization. While the latter depends only on the composition and shape of the object, the former also depends on the magnetization history. With common deperming techniques, a significant permanent signature may still remain, which confuses measurements of the induced component. We investigate a basic technique of separating the two. Measurements were done by moving the object along an aluminum rail while the three field components are recorded by a detector attached near the center. This is done first with the rail parallel to the Earth magnetic field and then with anti-parallel orientation. The reversal changes the sign of the induced- but not the permanent magnetization so that the two can be separated. Our preliminary results on a small iron block show excellent reproducibility. A considerable permanent magnetization was indeed present, resulting in a complex asymmetric signature. After separation, a much more symmetric induced signature was obtained that can be studied in detail and compared with theoretical calculations.
Abstract: One of the tasks of optical surveillance is to detect
anomalies in large amounts of image data. However, if the size of the
anomaly is very small, limited information is available to distinguish
it from the surrounding environment. Spectral detection provides a
useful source of additional information and may help to detect
anomalies with a size of a few pixels or less. Unfortunately, spectral
cameras are expensive because of the difficulty of separating two
spatial in addition to one spectral dimension. We investigate the
possibility of modifying a simple spectral line detector for outdoor
detection. This may be especially useful if the area of interest forms a
line, such as the horizon. We use a monochrome CCD that also
enables detection into the near infrared. A simple camera is attached
to the setup to determine which part of the environment is spectrally
imaged. Our preliminary results indicate that sensitive detection of
very small targets is indeed possible. Spectra could be taken from the
various targets by averaging columns in the line image. By imaging a
set of lines of various widths we found narrow lines that could not be
seen in the color image but remained visible in the spectral line
image. A simultaneous analysis of the entire spectra can produce
better results than visual inspection of the line spectral image. We are
presently developing calibration targets for spatial and spectral
focusing and alignment with the spatial camera. This will present
improved results and more use in outdoor application.