Abstract: The characterization and modeling of the dynamic
behavior of many built-up structures under vibration conditions is still
a subject of current research. The present study emphasizes the
theoretical investigation of slip damping in layered and jointed
welded cantilever structures using finite element approach.
Application of finite element method in damping analysis is relatively
recent, as such, some problems particularly slip damping analysis has
not received enough attention. To validate the finite element model
developed, experiments have been conducted on a number of mild
steel specimens under different initial conditions of vibration. Finite
element model developed affirms that the damping capacity of such
structures is influenced by a number of vital parameters such as;
pressure distribution, kinematic coefficient of friction and micro-slip
at the interfaces, amplitude, frequency of vibration, length and
thickness of the specimen. Finite element model developed can be
utilized effectively in the design of machine tools, automobiles,
aerodynamic and space structures, frames and machine members for
enhancing their damping capacity.
Abstract: In built-up structures, one of the effective ways of
dissipating unwanted vibration is to exploit the occurrence of slip at
the interfaces of structural laminates. The present work focuses on
the dynamic analysis of welded structures. A mathematical
formulation has been developed for the mechanism of slip damping
in layered and welded mild steel beams with unequal thickness
subjected to both periodic and non-periodic forces. It is observed that
a number of vital parameters such as; thickness ratio, pressure
distribution characteristics, relative slip and kinematic co-efficient of
friction at the interfaces, nature of exciting forces, length and
thickness of the beam specimen govern the damping characteristics of
these structures. Experimental verification has been carried out to
validate the analysis and study the effect of these parameters. The
developed damping model for the structure is found to be in fairly
good agreement with the measured data. Finally, the results of the
analysis are discussed and rationalized.