Abstract: This paper presents long term wind data analysis in terms of annual and diurnal variations at different areas of Libya. The data of the wind speed and direction are taken each ten minutes for a period, at least two years, are used in the analysis. ‘WindPRO’ software and Excel workbook were used for the wind statistics and energy calculations. As for Darnah, average speeds are 10m, 20m and 40m and 6.57 m/s, 7.18 m/s, and 8.09 m/s, respectively. Highest wind speeds are observed at SSW, followed by S, WNW and NW sectors. Lowest wind speeds are observed between N and E sectors. Most frequent wind directions are NW and NNW. Hence, wind turbines can be installed against these directions. The most powerful sector is NW (31.3% of total expected wind energy), followed by 17.9% SSW, 11.5% NNW and 8.2% WNW
In Excel workbook, an estimation of annual energy yield at position of Derna, Al-Maqrun, Tarhuna and Al-Asaaba meteorological mast has been done, considering a generic wind turbine of 1.65 MW. (mtORRES, TWT 82-1.65MW) in position of meteorological mast. Three other turbines have been tested and a reduction of 18% over the net AEP. At 80m, the estimation of energy yield for Derna, Al- Maqrun, Tarhuna and Asaaba is 6.78 GWh or 3390 equivalent hours, 5.80 GWh or 2900 equivalent hours, 4.91 GWh or 2454 equivalent hours and 5.08 GWh or 2541 equivalent hours respectively. It seems a fair value in the context of a possible development of a wind energy project in the areas, considering a value of 2400 equivalent hours as an approximate limit to consider a wind warm economically profitable. Furthermore, an estimation of annual energy yield at positions of Misalatha, Azizyah and Goterria meteorological mast has been done, considering a generic wind turbine of 2 MW. We found that, at 80 m the estimation of energy yield is 3.12 GWh or 1557 equivalent hours, 4.47 GWh or 2235 equivalent hours and 4.07GWh or 2033 respectively.
It seems a very poor value in the context of possible development of a wind energy project in the areas, considering a value of 2400 equivalent hours as an approximate limit to consider a wind warm economically profitable. Anyway, more data and a detailed wind farm study would be necessary to draw conclusions.
Abstract: Wind farms usually produce power irregularly, due to unpredictable change of wind speed. Accordingly, we should determine the penetration limit of wind power to consider stability of power system and build a facility to control the wind power. The operational limit of wind power is determined as the minimum between the technical limit and the dynamic limit of wind power. The technical limit is calculated by the number of generators and the dynamic limit is calculated by the constraint of frequency variation when a wind farm is disconnected suddenly. According to the determined operational limit of wind power, pitch angles of wind generators are controlled. PSS/E simulation results show that the pitch angles were correctly controlled when wind speeds are changed in addition to loads.
Abstract: Due to uncertainty of wind velocity, wind power generators don’t have deterministic output power. Utilizing wind power generation and thermal power plants together create new concerns for operation engineers of power systems. In this paper, a model is presented to implement the uncertainty of load and generated wind power which can be utilized in power system operation planning. Stochastic behavior of parameters is simulated by generating scenarios that can be solved by deterministic method. A mixed-integer linear programming method is used for solving deterministic generation scheduling problem. The proposed approach is applied to a 12-unit test system including 10 thermal units and 2 wind farms. The results show affectivity of piecewise linear model in unit commitment problems. Also using linear programming causes a considerable reduction in calculation times and guarantees convergence to the global optimum. Neglecting the uncertainty of wind velocity causes higher cost assessment of generation scheduling.
Abstract: Renewable energy systems are becoming a topic of
great interest and investment in the world. In recent years wind
power generation has experienced a very fast development in the
whole world. For planning and successful implementations of good
wind power plant projects, wind potential measurements are
required. In these projects, of great importance is the effective choice
of the micro location for wind potential measurements, installation of
the measurement station with the appropriate measuring equipment,
its maintenance and analysis of the gained data on wind potential
characteristics. In this paper, a wavelet transform has been applied to
analyze the wind speed data in the context of insight in the
characteristics of the wind and the selection of suitable locations that
could be the subject of a wind farm construction. This approach
shows that it can be a useful tool in investigation of wind potential.
Abstract: At present, it is very common to find renewable
energy resources, especially wind power, connected to distribution
systems. The impact of this wind power on voltage distribution levels
has been addressed in the literature. The majority of this works deals
with the determination of the maximum active and reactive power
that is possible to be connected on a system load bus, until the
voltage at that bus reaches the voltage collapse point. It is done by the
traditional methods of PV curves reported in many references.
Theoretical expression of maximum power limited by voltage
stability transfer through a grid is formulated using an exact
representation of distribution line with ABCD parameters. The
expression is used to plot PV curves at various power factors of a
radial system. Limited values of reactive power can be obtained. This
paper presents a method to study the relationship between the active
power and voltage (PV) at the load bus to identify the voltage
stability limit. It is a foundation to build a permitted working
operation region in complying with the voltage stability limit at the
point of common coupling (PCC) connected wind farm.
Abstract: As an effort to promote wind power industry in Korea,
Korea South-East Power Corporation has been developing 22MW
YeungHeung wind farm consisting of nine 2 to 3MW wind turbines
supplied by three manufacturers. To maximize its availability and
reliability and to solve the difficulty of operating three kinds of
SCADA systems, Korea Electric Power Corporation has been
developing a condition monitoring system integrated with control
functions. This paper presents the developed condition monitoring
system and its application to YeungHeung wind test bed, and the
design of its control functions.
Abstract: The use of wind energy for electricity generation is
growing rapidly across the world and in Portugal. However, the
geographical characteristics of the country along with the average
wind regime and with the environmental restrictions imposed to these
projects create limitations to the exploit of the onshore wind
resource. The best onshore wind spots are already committed and the
possibility of offshore wind farms in the Portuguese cost is now
being considered. This paper aims to make a contribution to the
evaluation of offshore wind power projects in Portugal. The technical
restrictions are addressed and the strategic, environmental and
financial interest of the project is analysed from the private company
and public points of view. The results suggest that additional support
schemes are required to ensure private investors interest for these
projects. Assuming an approach of direct substitution of energy
sources for electricity generation, the avoided CO2 equivalent
emissions for an offshore wind power project were quantified. Based
on the conclusions, future research is proposed to address the
environmental and social impacts of these projects.
Abstract: Due to the increasing penetration of wind energy, it is
necessary to possess design tools that are able to simulate the impact
of these installations in utility grids. In order to provide a net
contribution to this issue a detailed wind park model has been
developed and is briefly presented. However, the computational costs
associated with the performance of such a detailed model in
describing the behavior of a wind park composed by a considerable
number of units may render its practical application very difficult. To
overcome this problem integral manifolds theory has been applied to
reduce the order of the detailed wind park model, and therefore
create the conditions for the development of a dynamic equivalent
which is able to retain the relevant dynamics with respect to the
existing a.c. system. In this paper integral manifold method has been
introduced for order reduction. Simulation results of the proposed
method represents that integral manifold method results fit the
detailed model results with a higher precision than singular
perturbation method.
Abstract: The main aim of this work is to establish the
capabilities of new green buildings to ascertain off-grid electricity
generation based on the integration of wind turbines in the
conceptual model of a rotating tower [2] in Dubai. An in depth
performance analysis of the WinWind 3.0MW [3] wind turbine is
performed. Data based on the Dubai Meteorological Services is
collected and analyzed in conjunction with the performance analysis
of this wind turbine. The mathematical model is compared with
Computational Fluid Dynamics (CFD) results based on a conceptual
rotating tower design model. The comparison results are further
validated and verified for accuracy by conducting experiments on a
scaled prototype of the tower design. The study concluded that
integrating wind turbines inside a rotating tower can generate enough
electricity to meet the required power consumption of the building,
which equates to a wind farm containing 9 horizontal axis wind
turbines located at an approximate area of 3,237,485 m2 [14].
Abstract: Kish Islands in South of Iran is located in coastal
water near Hormozgan Province. Based on the wind 3-hour statistics
in Kish station, the mean annual windspeed in this Island is 8.6 knot
(4.3 m/s). The maximum windspeed recorded in this stations 47 knot
(23.5 m/s). In 45.7 percent of recorded times, windspeed has been
Zero or less than 8 knot which is not suitable to use the wind energy.
But in 54.3 percent of recorded times, windspeed has been more than
8 knot and suitable to use wind energy to run turbines. In 40.2
percent of recorded times, windspeed has been between 8 to 16 knot,
in 13 percent of times between 16 to 24 knot and in 1 percent of
times it has been higher than 24 knot. In this station, the direction of
winds higher than 8 is west and wind direction in Kish station is
stable in most times of the year.With regard to high – speed and
stable direction winds during the year and also shallow coasts near
this is land, it is possible to build offshore wind farms near Kish
Island and utilize wind energy produce the electricity required in this
Island during most of the year.
Abstract: This paper presents a reliability-based approach to select appropriate wind turbine types for a wind farm considering site-specific wind speed patterns. An actual wind farm in the northern region of Iran with the wind speed registration of one year is studied in this paper. An analytic approach based on total probability theorem is utilized in this paper to model the probabilistic behavior of both turbines- availability and wind speed. Well-known probabilistic reliability indices such as loss of load expectation (LOLE), expected energy not supplied (EENS) and incremental peak load carrying capability (IPLCC) for wind power integration in the Roy Billinton Test System (RBTS) are examined. The most appropriate turbine type achieving the highest reliability level is chosen for the studied wind farm.
Abstract: Wind farms (WFs) with high level of penetration are
being established in power systems worldwide more rapidly than
other renewable resources. The Independent System Operator (ISO),
as a policy maker, should propose appropriate places for WF
installation in order to maximize the benefits for the investors. There
is also a possibility of congestion relief using the new installation of
WFs which should be taken into account by the ISO when proposing
the locations for WF installation. In this context, efficient wind farm
(WF) placement method is proposed in order to reduce burdens on
congested lines. Since the wind speed is a random variable and load
forecasts also contain uncertainties, probabilistic approaches are used
for this type of study. AC probabilistic optimal power flow (P-OPF)
is formulated and solved using Monte Carlo Simulations (MCS). In
order to reduce computation time, point estimate methods (PEM) are
introduced as efficient alternative for time-demanding MCS.
Subsequently, WF optimal placement is determined using generation
shift distribution factors (GSDF) considering a new parameter
entitled, wind availability factor (WAF). In order to obtain more
realistic results, N-1 contingency analysis is employed to find the
optimal size of WF, by means of line outage distribution factors
(LODF). The IEEE 30-bus test system is used to show and compare
the accuracy of proposed methodology.
Abstract: This paper focuses on PSS/E modeling of wind farms
of Doubly-fed Induction Generator (DFIG) type and their impact on
issues of power system operation. Since Wind Turbine Generators
(WTG) don-t have the same characteristics as synchronous
generators, the appropriate modeling of wind farms is essential for
transmission system operators to analyze the best options of
transmission grid reinforcements as well as to evaluate the wind
power impact on reliability and security of supply. With the high
excepted penetration of wind power into the power system a
simultaneous loss of Wind Farm generation will put at risk power
system security and reliability. Therefore, the main wind grid code
requirements concern the fault ride through capability and frequency
operation range of wind turbines. In case of grid faults wind turbines
have to supply a definite reactive power depending on the
instantaneous voltage and to return quickly to normal operation.