Abstract: There is a growing interest in the use of ultrasonic speckle tracking for biomedical image formation of tissue deformation. Speckle tracking is angle independent and has an ability to differentiate soft tissue into benign and malignant regions. In this paper a simulation model for dynamic ultrasound scatterer is presented. The model composes Field-II ultrasonic scatterers and FEM (ANSYS-11) nodes as a regional tissue deformation. A performance evaluation is presented on axial displacement and strain fields estimation of a uniformly elastic model, using speckle tracking based 1D cross-correlation of optimally segmented pre and post-deformation frames. Optimum correlation window length is investigated in terms of highest signal-to-noise ratio (SNR) for a selected region of interest of a smoothed displacement field. Finally, gradient based strain field of both smoothed and non-smoothed displacement fields are compared. Simulation results from the model are shown to compare favorably with FEM results.
Abstract: We present the design of Analog front end (AFE) low noise pre-amplifier implemented in a high voltage 0.18-µm CMOS technology for a three dimensional ultrasound bio microscope (3D UBM) application. The fabricated chip has 4X16 pre-amplifiers implemented to interface a 2-D array of high frequency capacitive micro-machined ultrasound transducers (CMUT). Core AFE cell consists of a high-voltage pulser in the transmit path, and a low-noise transimpedance amplifier in the receive path. Proposed system offers a high image resolution by the use of high frequency CMUTs with associated high performance imaging electronics integrated together. Performance requirements and the design methods of the high bandwidth transimpedance amplifier are described in the paper. A single cell of transimpedance (TIA) amplifier and the bias circuit occupies a silicon area of 250X380 µm2 and the full chip occupies a total silicon area of 10x6.8 mm².
Abstract: For the improvement of the ability in detecting
small calcifications using Ultrasonography (US) we propose a
novel indicator of calcifications in an ultrasound B-mode image
without decrease in frame rate. Since the waveform of an
ultrasound pulse changes at a calcification position, the
decorrelation of adjacent scan lines occurs behind a
calcification. Therefore, we employ the decorrelation of
adjacent scan lines as an indicator of a calcification. The
proposed indicator depicted wires 0.05 mm in diameter at 2 cm
depth with a sensitivity of 86.7% and a specificity of 100%,
which were hardly detected in ultrasound B-mode images. This
study shows the potential of the proposed indicator to
approximate the detectable calcification size using an US
device to that of an X-ray imager, implying the possibility that
an US device will become a convenient, safe, and principal
clinical tool for the screening of breast cancer.
Abstract: An efficient reintegration of the disabled people in the
family and society should be fulfilled; hence it is strongly needful to assist their diminished functions or to replace the totally lost
functions. Assistive technology helps in neutralizing the impairment.
Recent advancements in embedded systems have opened up a vast
area of research and development for affordable and portable assistive devices for the visually impaired. Granted there are many assistive devices on the market that are able to detect obstacles, and numerous research and development currently in process to
alleviate the cause, unfortunately the cost of devices, size of
devices, intrusiveness and higher learning curve prevents the visually impaired from taking advantage of available devices. This
project aims at the design and implementation of a detachable unit
which is robust, low cost and user friendly, thus, trying to
aggrandize the functionality of the existing white cane, to concede above-knee obstacle detection. The designed obstruction detector
uses ultrasound sensors for detecting the obstructions before direct contact. It bestows haptic feedback to the user in accordance with the position of the obstacle.
Abstract: Because of the requirement for low sulfur content of
fuel oils, it is necessary to develop alternative methods for desulfurization of heavy fuel oil. Due to the disadvantages of HDS
technologies such as costs, safety and green environment, new
methods have been developed. Among these methods is ultrasoundassisted
oxidative desulfurization. Using ultrasound-assisted
oxidative desulfurization, compounds such as benzothiophene and
dibenzothiophene can be oxidized. As an alternative method is sulfur
elimination of heavy fuel oil by using of activated carbon in a packed column in batch condition. The removal of sulfur compounds in this
case to reach about 99%. The most important property of activated carbon is ability of it for adsorption, which is due to high surface area
and pore volume of it.
Abstract: The paper presents the multi-element synthetic
transmit aperture (MSTA) method with a small number of elements
transmitting and all elements apertures in medical ultrasound
imaging. As compared to the other methods MSTA allows to
increase the system frame rate and provides the best compromise
between penetration depth and lateral resolution.
In the experiments a 128-element linear transducer array with
0.3 mm pitch excited by a burst pulse of 125 ns duration were used.
The comparison of 2D ultrasound images of tissue mimicking
phantom obtained using the STA and the MSTA methods is
presented to demonstrate the benefits of the second approach. The
results were obtained using SA algorithm with transmit and receive
signals correction based on a single element directivity function.
Abstract: Most of the drugs used for pharmaceutical purposes
are poorly water-soluble drugs. About 40% of all newly discovered
drugs are lipophilic and the numbers of lipophilic drugs seem to
increase more and more. Drug delivery systems such as
nanoparticles, micelles or liposomes are applied to improve their
solubility and thus their bioavailability. Besides various techniques of
solubilization, oil-in-water emulsions are often used to incorporate
lipophilic drugs into the oil phase. To stabilize emulsions surface
active substances (surfactants) are generally used. An alternative
method to avoid the application of surfactants was of great interest.
One possibility is to develop O/W-emulsion without any addition of
surface active agents or the so called “surfactant-free emulsion or
SFE”. The aim of this study was to develop and characterize SFE as a
drug carrier by varying the production conditions. Lidocaine base
was used as a model drug. The injection method was developed.
Effects of ultrasound as well as of temperature on the properties of
the emulsion were studied. Particle sizes and release were
determined. The long-term stability up to 30 days was performed.
The results showed that the surfactant-free O/W emulsions with
pharmaceutical oil as drug carrier can be produced.
Abstract: Aluminum salt that is generally presents as a solid
phase in the water purification sludge (WPS) can be dissolved,
recovering a liquid phase, by adding strong acid to the sludge solution.
According to the reaction kinetics, when reactant is in the form of
small particles with a large specific surface area, or when the reaction
temperature is high, the quantity of dissolved aluminum salt or
reaction rate, respectively are high. Therefore, in this investigation,
water purification sludge (WPS) solution was treated with ultrasonic
waves to break down the sludge, and different acids (1 N HCl and 1 N
H2SO4) were used to acidify it. Acid dosages that yielded the solution
pH of less than two were used. The results thus obtained indicate that
the quantity of dissolved aluminum in H2SO4-acidified solution
exceeded that in HCl-acidified solution. Additionally, ultrasonic
treatment increased the rate of dissolution of aluminum and the
amount dissolved. The quantity of aluminum dissolved at 60℃ was 1.5
to 2.0 times higher than that at 25℃.
Abstract: Segmentation in ultrasound images is challenging due to the interference from speckle noise and fuzziness of boundaries. In this paper, a segmentation scheme using fuzzy c-means (FCM) clustering incorporating both intensity and texture information of images is proposed to extract breast lesions in ultrasound images. Firstly, the nonlinear structure tensor, which can facilitate to refine the edges detected by intensity, is used to extract speckle texture. And then, a spatial FCM clustering is applied on the image feature space for segmentation. In the experiments with simulated and clinical ultrasound images, the spatial FCM clustering with both intensity and texture information gets more accurate results than the conventional FCM or spatial FCM without texture information.
Abstract: Speckled images arise when coherent microwave,
optical, and acoustic imaging techniques are used to image an object, surface or scene. Examples of coherent imaging systems include synthetic aperture radar, laser imaging systems, imaging sonar
systems, and medical ultrasound systems. Speckle noise is a form of object or target induced noise that results when the surface of the object is Rayleigh rough compared to the wavelength of the illuminating radiation. Detection and estimation in images corrupted
by speckle noise is complicated by the nature of the noise and is not
as straightforward as detection and estimation in additive noise. In
this work, we derive stochastic models for speckle noise, with an emphasis on speckle as it arises in medical ultrasound images. The
motivation for this work is the problem of segmentation and tissue classification using ultrasound imaging. Modeling of speckle in this
context involves partially developed speckle model where an underlying Poisson point process modulates a Gram-Charlier series
of Laguerre weighted exponential functions, resulting in a doubly
stochastic filtered Poisson point process. The statistical distribution of partially developed speckle is derived in a closed canonical form.
It is observed that as the mean number of scatterers in a resolution cell is increased, the probability density function approaches an
exponential distribution. This is consistent with fully developed speckle noise as demonstrated by the Central Limit theorem.
Abstract: The sonochemical decolorization and degradation of azo dye Methyl violet using Fenton-s reagent in the presence of a high-frequency acoustic field has been investigated. Dyeing and textile effluents are the major sources of azo dyes, and are most troublesome among industrial wastewaters, causing imbalance in the eco-system. The effect of various operating conditions (initial concentration of dye, liquid-phase temperature, ultrasonic power and frequency and process time) on sonochemical degradation was investigated. Conversion was found to increase with increase in initial concentration, temperature, power level and frequency. Both horntype and tank-type sonicators were used, at various power levels (250W, 400W and 500W) for frequencies ranging from 20 kHz - 1000 kHz. A 'Process Intensification' parameter PI, was defined to quantify the enhancement of the degradation reaction by ultrasound when compared to control (i.e., without ultrasound). The present work clearly demonstrates that a high-frequency ultrasonic bath can be used to achieve higher process throughput and energy efficiency at a larger scale of operation.
Abstract: The work describes the use of a synthetic transmit
aperture (STA) with a single element transmitting and all elements
receiving in medical ultrasound imaging. STA technique is a novel
approach to today-s commercial systems, where an image is acquired
sequentially one image line at a time that puts a strict limit on the
frame rate and the amount of data needed for high image quality. The
STA imaging allows to acquire data simultaneously from all
directions over a number of emissions, and the full image can be
reconstructed.
In experiments a 32-element linear transducer array with 0.48 mm
inter-element spacing was used. Single element transmission aperture
was used to generate a spherical wave covering the full image region.
The 2D ultrasound images of wire phantom are presented obtained
using the STA and commercial ultrasound scanner Antares to
demonstrate the benefits of the SA imaging.
Abstract: A higher order spline interpolated contour obtained
with up-sampling of homogenously distributed coordinates for
segmentation of kidney region in different classes of ultrasound
kidney images has been developed and presented in this paper. The
performance of the proposed method is measured and compared with
modified snake model contour, Markov random field contour and
expert outlined contour. The validation of the method is made in
correspondence with expert outlined contour using maximum coordinate
distance, Hausdorff distance and mean radial distance
metrics. The results obtained reveal that proposed scheme provides
optimum contour that agrees well with expert outlined contour.
Moreover this technique helps to preserve the pixels-of-interest
which in specific defines the functional characteristic of kidney. This
explores various possibilities in implementing computer-aided
diagnosis system exclusively for US kidney images.
Abstract: Functional gastrointestinal disorders affect millions of people spread all age regardless of race and sex. There are, however, rare diagnostic methods for the functional gastrointestinal disorders because functional disorders show no evidence of organic and physical causes. Our research group identified recently that the gastrointestinal tract well in the patients with the functional gastrointestinal disorders becomes more rigid than healthy people when palpating the abdominal regions overlaying the gastrointestinal tract. Aim of this study is, therefore, to develop a diagnostic system for the functional gastrointestinal disorders based on ultrasound technique, which can quantify the characteristic above related to the rigidity of the gastrointestinal tract well. Ultrasound system was designed. The system consisted of transmitter, ultrasonic transducer, receiver, TGC, and CPLD, and verified via a phantom test. For the phantom test, ten soft-tissue specimens were harvested from porcine. Five of them were then treated chemically to mimic a rigid condition of gastrointestinal tract well, which was induced by functional gastrointestinal disorders. Additionally, the specimens were tested mechanically to identify if the mimic was reasonable. The customized ultrasound system was finally verified through application to human subjects with/without functional gastrointestinal disorders (Normal and Patient Groups). It was identified from the mechanical test that the chemically treated specimens were more rigid than normal specimen. This finding was favorably compared with the result obtained from the phantom test. The phantom test also showed that ultrasound system well described the specimen geometric characteristics and detected an alteration in the specimens. The maximum amplitude of the ultrasonic reflective signal in the rigid specimens (0.2±0.1Vp-p) at the interface between the fat and muscle layers was explicitly higher than that in the normal specimens (0.1±0.0Vp-p). Clinical tests using our customized ultrasound system for human subject showed that the maximum amplitudes of the ultrasonic reflective signals near to the gastrointestinal tract well for the patient group (2.6±0.3Vp-p) were generally higher than those in normal group (0.1±0.2Vp-p). Here, maximum reflective signals was appeared at 20mm depth approximately from abdominal skin for all human subjects, corresponding to the location of the boundary layer close to gastrointestinal tract well. These results suggest that newly designed diagnostic system based on ultrasound technique may diagnose enough the functional gastrointestinal disorders.
Abstract: In this paper, we propose a novel algorithm for
delineating the endocardial wall from a human heart ultrasound scan.
We assume that the gray levels in the ultrasound images are
independent and identically distributed random variables with
different Rician Inverse Gaussian (RiIG) distributions. Both synthetic
and real clinical data will be used for testing the algorithm. Algorithm
performance will be evaluated using the expert radiologist evaluation
of a soft copy of an ultrasound scan during the scanning process and
secondly, doctor’s conclusion after going through a printed copy of
the same scan. Successful implementation of this algorithm should
make it possible to differentiate normal from abnormal soft tissue and
help disease identification, what stage the disease is in and how best
to treat the patient. We hope that an automated system that uses this
algorithm will be useful in public hospitals especially in Third World
countries where problems such as shortage of skilled radiologists and
shortage of ultrasound machines are common. These public hospitals
are usually the first and last stop for most patients in these countries.
Abstract: Image compression is one of the most important
applications Digital Image Processing. Advanced medical imaging
requires storage of large quantities of digitized clinical data. Due to
the constrained bandwidth and storage capacity, however, a medical
image must be compressed before transmission and storage. There
are two types of compression methods, lossless and lossy. In Lossless
compression method the original image is retrieved without any
distortion. In lossy compression method, the reconstructed images
contain some distortion. Direct Cosine Transform (DCT) and Fractal
Image Compression (FIC) are types of lossy compression methods.
This work shows that lossy compression methods can be chosen for
medical image compression without significant degradation of the
image quality. In this work DCT and Fractal Compression using
Partitioned Iterated Function Systems (PIFS) are applied on different
modalities of images like CT Scan, Ultrasound, Angiogram, X-ray
and mammogram. Approximately 20 images are considered in each
modality and the average values of compression ratio and Peak
Signal to Noise Ratio (PSNR) are computed and studied. The quality
of the reconstructed image is arrived by the PSNR values. Based on
the results it can be concluded that the DCT has higher PSNR values
and FIC has higher compression ratio. Hence in medical image
compression, DCT can be used wherever picture quality is preferred
and FIC is used wherever compression of images for storage and
transmission is the priority, without loosing picture quality
diagnostically.
Abstract: Medical image modalities such as computed
tomography (CT), magnetic resonance imaging (MRI), ultrasound
(US), X-ray are adapted to diagnose disease. These modalities
provide flexible means of reviewing anatomical cross-sections and
physiological state in different parts of the human body. The raw
medical images have a huge file size and need large storage
requirements. So it should be such a way to reduce the size of those
image files to be valid for telemedicine applications. Thus the image
compression is a key factor to reduce the bit rate for transmission or
storage while maintaining an acceptable reproduction quality, but it is
natural to rise the question of how much an image can be compressed
and still preserve sufficient information for a given clinical
application. Many techniques for achieving data compression have
been introduced. In this study, three different MRI modalities which
are Brain, Spine and Knee have been compressed and reconstructed
using wavelet transform. Subjective and objective evaluation has
been done to investigate the clinical information quality of the
compressed images. For the objective evaluation, the results show
that the PSNR which indicates the quality of the reconstructed image
is ranging from (21.95 dB to 30.80 dB, 27.25 dB to 35.75 dB, and
26.93 dB to 34.93 dB) for Brain, Spine, and Knee respectively. For
the subjective evaluation test, the results show that the compression
ratio of 40:1 was acceptable for brain image, whereas for spine and
knee images 50:1 was acceptable.
Abstract: The disaster from functional gastrointestinal disorders has detrimental impact on the quality of life of the effected population and imposes a tremendous social and economic burden. There are, however, rare diagnostic methods for the functional gastrointestinal disorders. Our research group identified recently that the gastrointestinal tract well in the patients with the functional gastrointestinal disorders becomes more rigid than healthy people when palpating the abdominal regions overlaying the gastrointestinal tract. Objective of current study is, therefore, identify feasibility of a diagnostic system for the functional gastrointestinal disorders based on ultrasound technique, which can quantify the characteristics above. Two-dimensional finite difference (FD) models (one normal and two rigid model) were developed to analyze the reflective characteristic (displacement) on each soft-tissue layer responded after application of ultrasound signals. The FD analysis was then based on elastic ultrasound theory. Validation of the model was performed via comparison of the characteristic of the ultrasonic responses predicted by FD analysis with that determined from the actual specimens for the normal and rigid conditions. Based on the results from FD analysis, ultrasound system for diagnosis of the functional gastrointestinal disorders was developed and clinically tested via application of it to 40 human subjects with/without functional gastrointestinal disorders who were assigned to Normal and Patient Groups. The FD models were favorably validated. The results from FD analysis showed that the maximum displacement amplitude in the rigid models (0.12 and 0.16) at the interface between the fat and muscle layers was explicitly less than that in the normal model (0.29). The results from actual specimens showed that the maximum amplitude of the ultrasonic reflective signal in the rigid models (0.2±0.1Vp-p) at the interface between the fat and muscle layers was explicitly higher than that in the normal model (0.1±0.2 Vp-p). Clinical tests using our customized ultrasound system showed that the maximum amplitudes of the ultrasonic reflective signals near to the gastrointestinal tract well for the patient group (2.6±0.3 Vp-p) were generally higher than those in normal group (0.1±0.2 Vp-p). Here, maximum reflective signals was appeared at 20mm depth approximately from abdominal skin for all human subjects, corresponding to the location of the boundary layer close to gastrointestinal tract well. These findings suggest that our customized ultrasound system using the ultrasonic reflective signal may be helpful to the diagnosis of the functional gastrointestinal disorders.
Abstract: The paper presents the study of synthetic transmit
aperture method applying the Golay coded transmission for medical
ultrasound imaging. Longer coded excitation allows to increase the
total energy of the transmitted signal without increasing the peak
pressure. Signal-to-noise ratio and penetration depth are improved
maintaining high ultrasound image resolution.
In the work the 128-element linear transducer array with 0.3 mm
inter-element spacing excited by one cycle and the 8 and 16-bit
Golay coded sequences at nominal frequencies 4 MHz was used.
Single element transmission aperture was used to generate a spherical
wave covering the full image region and all the elements received the
echo signals. The comparison of 2D ultrasound images of the wire
phantom as well as of the tissue mimicking phantom is presented to
demonstrate the benefits of the coded transmission. The results were
obtained using the synthetic aperture algorithm with transmit and
receive signals correction based on a single element directivity
function.
Abstract: Ultrasound is useful in demonstrating bone mineral
density of regenerating osseous tissue as well as structural alterations.
A proposed ultrasound method, which included ultrasonography and
acoustic parameters measurement, was employed to evaluate its
efficacy in monitoring the bone callus changes in a rabbit tibial
distraction osteogenesis (DO) model.
The findings demonstrated that ultrasonographic images depicted
characteristic changes of the bone callus, typical of histology findings,
during the distraction phase. Follow-up acoustic parameters
measurement of the bone callus, including speed of sound, reflection
and attenuation, showed significant linear changes over time during
the distraction phase. The acoustic parameters obtained during the
distraction phase also showed moderate to strong correlation with
consolidated bone callus density and micro-architecture measured by
micro-computed tomography at the end of the consolidation phase.
The results support the preferred use of ultrasound imaging in the
early monitoring of bone callus changes during DO treatment.