Abstract: Future astronomical projects on large space x-ray
imaging telescopes require novel substrates and technologies for the
construction of their reflecting mirrors. The mirrors must be
lightweight and precisely shaped to achieve large collecting area with
high angular resolution. The new materials and technologies must be
cost-effective. Currently, the most promising materials are glass or
silicon foils. We focused on precise shaping these foils by thermal
forming process. We studied free and forced slumping in the
temperature region of hot plastic deformation and compared the
shapes obtained by the different slumping processes. We measured
the shapes and the surface quality of the foils. In the experiments, we
varied both heat-treatment temperature and time following our
experiment design. The obtained data and relations we can use for
modeling and optimizing the thermal forming procedure.
Abstract: Multicast transmissions allow an host (the source) to send only one flow bound for a group of hosts (the receivers). Any equipment eager to belong to the group may explicitly register itself to that group via its multicast router. This router will be given the responsibility to convey all information relating to the group to all registered hosts. However in an environment in which the final receiver or the source frequently moves, the multicast flows need particular treatment. This constitutes one of the multicast transmissions problems around which several proposals were made in the Mobile IPv6 case in general. In this article, we describe the problems involved in this IPv6 multicast mobility and the existing proposals for their resolution. Then architecture will be proposed aiming to satisfy and optimize these transmissions in the specific case of a mobile multicast receiver in NC-HMIPv6 environment.
Abstract: Macrobenthos distribution along the coastal waters of
Penang National Park was studid to estimate the effect of different
environmental parameters at three stations, during six sampling
months, from June 2010 to April 2011. The aim of this survey was to
investigate different environment stress over soft bottom polychaete
community along Teluk Ketapang and Pantai Acheh (Penang
National Park) over a year period. Variations in the polychaete
community were evaluated using univariate and multivariate
methods. A total of 604 individuals were examined which was
grouped into 23 families. Family Nereidae was the most abundant
(22.68%), followed by Spionidae (22.02%), Hesionidae (12.58%),
Nephtylidae (9.27%) and Orbiniidae (8.61%). It is noticeable that
good results can only be obtained on the basis of good taxonomic
resolution. The maximum Shannon-Wiener diversity (H'=2.16) was
recorded at distance 200m and 1200m (August 2010) in Teluk
Ketapang and lowest value of diversity was found at distance 1200m
(December 2010) in Teluk Ketapang.
Abstract: In this paper, we propose a novel time-frequency distribution (TFD) for the analysis of multi-component signals. In particular, we use synthetic as well as real-life speech signals to prove the superiority of the proposed TFD in comparison to some existing ones. In the comparison, we consider the cross-terms suppression and the high energy concentration of the signal around its instantaneous frequency (IF).
Abstract: Cerium-doped lanthanum bromide LaBr3:Ce(5%)
crystals are considered to be one of the most advanced scintillator
materials used in PET scanning, combining a high light yield, fast
decay time and excellent energy resolution. Apart from the correct
choice of scintillator, it is also important to optimise the detector
geometry, not least in terms of source-to-detector distance in order to
obtain reliable measurements and efficiency. In this study a
commercially available 25 mm x 25 mm BrilLanCeTM 380 LaBr3: Ce
(5%) detector was characterised in terms of its efficiency at varying
source-to-detector distances. Gamma-ray spectra of 22Na, 60Co, and
137Cs were separately acquired at distances of 5, 10, 15, and 20cm. As
a result of the change in solid angle subtended by the detector, the
geometric efficiency reduced in efficiency with increasing distance.
High efficiencies at low distances can cause pulse pile-up when
subsequent photons are detected before previously detected events
have decayed. To reduce this systematic error the source-to-detector
distance should be balanced between efficiency and pulse pile-up
suppression as otherwise pile-up corrections would need to be
necessary at short distances. In addition to the experimental
measurements Monte Carlo simulations have been carried out for the
same setup, allowing a comparison of results. The advantages and
disadvantages of each approach have been highlighted.
Abstract: Quality of 2D and 3D cross-sectional images produce
by Computed Tomography primarily depend upon the degree of
precision of primary and secondary X-Ray intensity detection.
Traditional method of primary intensity detection is apt to errors.
Recently the X-Ray intensity measurement system along with smart
X-Ray sensors is developed by our group which is able to detect
primary X-Ray intensity unerringly. In this study a new smart X-Ray
sensor is developed using Light-to-Frequency converter TSL230
from Texas Instruments which has numerous advantages in terms of
noiseless data acquisition and transmission. TSL230 construction is
based on a silicon photodiode which converts incoming X-Ray
radiation into the proportional current signal. A current to frequency
converter is attached to this photodiode on a single monolithic CMOS
integrated circuit which provides proportional frequency count to
incoming current signal in the form of the pulse train. The frequency
count is delivered to the center of PICDEM FS USB board with
PIC18F4550 microcontroller mounted on it. With highly compact
electronic hardware, this Demo Board efficiently read the smart
sensor output data. The frequency output approaches overcome
nonlinear behavior of sensors with analog output thus un-attenuated
X-Ray intensities could be measured precisely and better
normalization could be acquired in order to attain high resolution.
Abstract: We present a new method to reconstruct a temporally
coherent 3D animation from single or multi-view RGB-D video data
using unbiased feature point sampling. Given RGB-D video data, in
form of a 3D point cloud sequence, our method first extracts feature
points using both color and depth information. In the subsequent
steps, these feature points are used to match two 3D point clouds in
consecutive frames independent of their resolution. Our new motion
vectors based dynamic alignement method then fully reconstruct
a spatio-temporally coherent 3D animation. We perform extensive
quantitative validation using novel error functions to analyze the
results. We show that despite the limiting factors of temporal and
spatial noise associated to RGB-D data, it is possible to extract
temporal coherence to faithfully reconstruct a temporally coherent
3D animation from RGB-D video data.
Abstract: Phase-Contrast MR imaging methods are widely used
for measurement of blood flow velocity components. Also there are
some other tools such as CT and Ultrasound for velocity map
detection in intravascular studies. These data are used in deriving
flow characteristics. Some clinical applications are investigated
which use pressure distribution in diagnosis of intravascular disorders
such as vascular stenosis. In this paper an approach to the problem of
measurement of intravascular pressure field by using velocity field
obtained from flow images is proposed. The method presented in this
paper uses an algorithm to calculate nonlinear equations of Navier-
Stokes, assuming blood as an incompressible and Newtonian fluid.
Flow images usually suffer the lack of spatial resolution. Our
attempt is to consider the effect of spatial resolution on the pressure
distribution estimated from this method. In order to achieve this aim,
velocity map of a numerical phantom is derived at six different
spatial resolutions. To determine the effects of vascular stenoses on
pressure distribution, a stenotic phantom geometry is considered. A
comparison between the pressure distribution obtained from the
phantom and the pressure resulted from the algorithm is presented. In
this regard we also compared the effects of collocated and staggered
computational grids on the pressure distribution resulted from this
algorithm.
Abstract: The ultimate goal of this article is to develop a robust and accurate numerical method for solving hyperbolic conservation laws in one and two dimensions. A hybrid numerical method, coupling a cheap fourth order total variation diminishing (TVD) scheme [1] for smooth region and a Robust seventh-order weighted non-oscillatory (WENO) scheme [2] near discontinuities, is considered. High order multi-resolution analysis is used to detect the high gradients regions of the numerical solution in order to capture the shocks with the WENO scheme, while the smooth regions are computed with fourth order total variation diminishing (TVD). For time integration, we use the third order TVD Runge-Kutta scheme. The accuracy of the resulting hybrid high order scheme is comparable with these of WENO, but with significant decrease of the CPU cost. Numerical demonstrates that the proposed scheme is comparable to the high order WENO scheme and superior to the fourth order TVD scheme. Our scheme has the added advantage of simplicity and computational efficiency. Numerical tests are presented which show the robustness and effectiveness of the proposed scheme.