Abstract: This paper proposes a three-phase four-wire currentcontrolled
Voltage Source Inverter (CC-VSI) for both power quality
improvement and PV energy extraction. For power quality
improvement, the CC-VSI works as a grid current-controlling shunt
active power filter to compensate for harmonic and reactive power of
loads. Then, the PV array is coupled to the DC bus of the CC-VSI
and supplies active power to the grid. The MPPT controller employs
the particle swarm optimization technique. The output of the MPPT
controller is a DC voltage that determines the DC-bus voltage
according to PV maximum power. The PSO method is simple and
effective especially for a partially shaded PV array. From computer
simulation results, it proves that grid currents are sinusoidal and inphase
with grid voltages, while the PV maximum active power is
delivered to loads.
Abstract: This paper presents the impact study of apparent
reactance injected by series Flexible AC Transmission System
(FACTS) i.e. Thyristor Controlled Series Reactor (TCSR) on the
measured impedance of a 400 kV single electrical transmission line
in the presence of phase to earth fault with fault resistance. The study
deals with an electrical transmission line of Eastern Algerian
transmission networks at Group Sonelgaz (Algerian Company of
Electrical and Gas) compensated by TCSR connected at midpoint of
the line. This compensator used to inject active and reactive powers
is controlled by three TCSR-s. The simulations results investigate the
impacts of the TCSR on the parameters of short circuit calculation
and parameters of measured impedance by distance relay in the
presence of earth fault for three cases study.
Abstract: Most electrical distribution systems are incurring large
losses as the loads are wide spread, inadequate reactive power
compensation facilities and their improper control. A typical static
VAR compensator consists of capacitor bank in binary sequential
steps operated in conjunction with a thyristor controlled reactor of the
smallest step size. This SVC facilitates stepless control of reactive
power closely matching with load requirements so as to maintain
power factor nearer to unity. This type of SVC-s requiring a
appropriately controlled TCR. This paper deals with an air cored
reactor suitable for distribution transformer of 3phase, 50Hz, Dy11,
11KV/433V, 125 KVA capacity. Air cored reactors are designed,
built, tested and operated in conjunction with capacitor bank in five
binary sequential steps. It is established how the delta connected TCR
minimizes the harmonic components and the operating range for
various electrical quantities as a function of firing angle is
investigated. In particular firing angle v/s line & phase currents, D.C.
components, THD-s, active and reactive powers, odd and even triplen
harmonics, dominant characteristic harmonics are all investigated and
range of firing angle is fixed for satisfactory operation. The harmonic
spectra for phase and line quantities at specified firing angles are
given. In case the TCR is operated within the bound specified in this
paper established through simulation studies are yielding the best
possible operating condition particularly free from all dominant
harmonics.