Abstract: The elimimation of mefenamic acid has been carried
out by photolysis, ozonation, adsorption onto activated carbon (AC)
and combinations of the previous single systems (O3+AC and
O3+UV). The results obtained indicate that mefenamic acid is not
photo-reactive, showing a relatively low quantum yield of the order
of 6 x 10-4 mol Einstein-1. Application of ozone to mefenamic
aqueous solutions instantaneously eliminates the pharmaceutical,
achieving simultaneously a 40% of mineralization. Addition of AC to
the ozonation process does not enhance the process, moreover,
mineralization is completely inhibited if compared to results obtained
by single ozonation. The combination of ozone and UV radiation led
to the best results in terms of mineralization (60% after 120 min).
Abstract: The aerodynamic noise radiation from a side view mirror (SVM) in the high-speed airflow is calculated by the combination of unsteady incompressible fluid flow analysis and acoustic analysis. The transient flow past the generic SVM is simulated with variable turbulence model, namely DES Detached Eddy Simulation and LES (Large Eddy Simulation). Detailed velocity vectors and contour plots of the time-varying velocity and pressure fields are presented along cut planes in the flow-field. Mean and transient pressure are also monitored at several points in the flow field and compared to corresponding experimentally data published in literature. The acoustic predictions made using the Ffowcs-Williams-Hawkins acoustic analogy (FW-H) and the boundary element (BEM).
Abstract: The wide increase and diffusion on telecommunication
technologies have caused a huge spread of electromagnetic sources
in most European Countries. Since the public is continuously being
exposed to electromagnetic radiation the possible health effects have
become the focus of population concerns. As a result, electromagnetic
field monitoring stations which control field strength in commercial
frequency bands are being placed on the flat roof of many buildings.
However there is no guidance on where to place them. This paper
presents an analysis of frequency, polarization and angles of incidence
of a plane wave which impinges on a flat roof security wall and its
dependence on electromagnetic field strength meters placement.
Abstract: Excilamps are new UV sources with great potential
for application in wastewater treatment. In the present work, a XeBr
excilamp emitting radiation at 283 nm has been used for the
photodegradation of 4-chlorophenol within a range of concentrations
from 50 to 500 mg L-1. Total removal of 4-chlorophenol was
achieved for all concentrations assayed. The two main photoproduct
intermediates formed along the photodegradation process,
benzoquinone and hydroquinone, although not being completely
removed, remain at very low residual concentrations. Such
concentrations are insignificant compared to the 4-chlorophenol
initial ones and non-toxic. In order to simulate the process and scaleup,
a kinetic model has been developed and validated from the
experimental data.
Abstract: A nucleotide sequence can be expressed as a numerical sequence when each nucleotide is assigned its proton number. A resulting gene numerical sequence can be investigated for its fractal dimension in terms of evolution and chemical properties for comparative studies. We have investigated such nucleotide fluctuation in the 16S rRNA gene of archaea thermophiles. The studied archaea thermophiles were archaeoglobus fulgidus, methanothermobacter thermautotrophicus, methanocaldococcus jannaschii, pyrococcus horikoshii, and thermoplasma acidophilum. The studied five archaea-euryarchaeota thermophiles have fractal dimension values ranging from 1.93 to 1.97. Computer simulation shows that random sequences would have an average of about 2 with a standard deviation about 0.015. The fractal dimension was found to correlate (negative correlation) with the thermophile-s optimal growth temperature with R2 value of 0.90 (N =5). The inclusion of two aracheae-crenarchaeota thermophiles reduces the R2 value to 0.66 (N = 7). Further inclusion of two bacterial thermophiles reduces the R2 value to 0.50 (N =9). The fractal dimension is correlated (positive) to the sequence GC content with an R2 value of 0.89 for the five archaea-euryarchaeota thermophiles (and 0.74 for the entire set of N = 9), although computer simulation shows little correlation. The highest correlation (positive) was found to be between the fractal dimension and di-nucleotide Shannon entropy. However Shannon entropy and sequence GC content were observed to correlate with optimal growth temperature having an R2 of 0.8 (negative), and 0.88 (positive), respectively, for the entire set of 9 thermophiles; thus the correlation lacks species specificity. Together with another correlation study of bacterial radiation dosage with RecA repair gene sequence fractal dimension, it is postulated that fractal dimension analysis is a sensitive tool for studying the relationship between genotype and phenotype among closely related sequences.
Abstract: Microwave heating process has been developed about sixty years while measurement system has also progressed. Because of irradiation of high frequency of microwave, researchers have been utilized many costly technical instrument measuring parameters to evaluate the performance of microwave heating system. Therefore, this paper is intended to present an easier and feasible efficiency measurement method. It can help inspecting efficiency of microwave heating system with good accuracy, while the method can also give reference to optimizing procedure for microwave heating system for various load material
Abstract: This paper presents a review of an 8-year study on radiation effects in commercial memory devices operating within the main on-board computer system OBC386 of the Algerian microsatellite Alsat-1. A statistical analysis of single-event upset (SEU) and multiple-bit upset (MBU) activity in these commercial memories shows that the typical SEU rate at alsat-1's orbit is 4.04 × 10-7 SEU/bit/day, where 98.6% of these SEUs cause single-bit errors, 1.22% cause double-byte errors, and the remaining SEUs result in multiple-bit and severe errors.
Abstract: A study concerning the photocatalytic decolourization
of Congo red (CR) dye, over artificial UV irradiation is presented.
Photocatalysts based on a commercial titanium dioxide (TiO2)
modified with transition metals (Ni, Cu and Zn) were used. The
dopage method used was wet impregnation. A TiO2 sample without
salt was subjected to the same hydrothermal treatment to be used as
reference. Congo red solutions to several pH conditions (natural and
basic) were used to evaluate photocatalytic performance of each
doped catalysts. Photodecolourization percentage was measured
spectrofotrometically after 3 h of treatment to 499 nm as response
variable. Kinetics investigations of photodegradation indicated that
reactions obey to Langmuir-Hinshelwood model and pseudo–first
order law. The rate constant studies of photocatalytic decolourization
reactions for Zn–TiO2 and Cu–TiO2 photocatalysts indicated that in
all cases the rate constant of the reaction was higher than that of TiO2
undoped. These results show that nature of the metal modifying the
TiO2 influence on the efficiency of the photocatalyst evaluated in
process. Ni does not present an additional effect compared with TiO2,
while Zn enhances the photoactivity due to its electronic properties.
Abstract: In this work, an attempt is made to design an optimal
wind/pv/diesel hybrid power system for a village of Ain Merane,
Chlef, Algeria, where the wind speed and solar radiation
measurements were made. The aim of this paper is the optimization
of a hybrid wind/solar/diesel system applied in term of technical and
economic feasibility by simulation using HOMER. A comparison
was made between the performance of wind/pv/diesel system and the
classic connecting system.
Abstract: The Brazilian legislation has only established
diagnostic reference levels (DRLs) in terms of Multiple Scan
Average Dose (MSAD) as a quality control parameter for computed
tomography (CT) scanners. Compliance with DRLs can be verified
by measuring the Computed Tomography Kerma Index (Ca,100) with
a pencil ionization chamber or by obtaining the kerma distribution in
CT scans with radiochromic films or rod shape lithium fluoride
termoluminescent dosimeters (TLD-100). TL dosimeters were used
to record kerma profiles and to determine MSAD values of a Bright
Speed model GE CT scanner. Measurements were done with
radiochromic films and TL dosimeters distributed in cylinders
positioned in the center and in four peripheral bores of a standard
polymethylmethacrylate (PMMA) body CT dosimetry phantom.
Irradiations were done using a protocol for adult chest. The
maximum values were found at the midpoint of the longitudinal axis.
The MSAD values obtained with three dosimetric techniques were
compared.
Abstract: Interventional cardiologists are at greater risk from
radiation exposure as a result of the procedures they undertake than
most other medical specialists. A study was performed to evaluate
operator dose during interventional cardiology procedures and to
establish methods of operator dose reduction with a radiation
protective device. Different procedure technique and use of
protective tools can explain big difference in the annual equivalent
dose received by the professionals. Strategies to prevent and
monitor radiation exposure, advanced protective shielding and
effective radiation monitoring methods should be applied.
Abstract: This paper proposes a power-controlled scheduling scheme for devices using a directional antenna in smart home. In the case of the home network using directional antenna, devices can concurrently transmit data in the same frequency band. Accordingly, the throughput increases compared to that of devices using omni-directional antenna in proportional to the number of concurrent transmissions. Also, the number of concurrent transmissions depends on the beamwidth of antenna, the number of devices operating in the network , transmission power, interference and so on. In particular, the less transmission power is used, the more concurrent transmissions occur due to small transmission range. In this paper, we considered sub-optimal scheduling scheme for throughput maximization and power consumption minimization. In the scheme, each device is equipped with a directional antenna. Various beamwidths, path loss components, and antenna radiation efficiencies are considered. Numerical results show that the proposed schemes outperform the scheduling scheme using directional antennas without power control.
Abstract: Monitoring lightning electromagnetic pulses (sferics)
and other terrestrial as well as extraterrestrial transient radiation signals
is of considerable interest for practical and theoretical purposes
in astro- and geophysics as well as meteorology. Managing a continuous
flow of data, automisation of the detection and classification
process is important. Features based on a combination of wavelet and
statistical methods proved efficient for analysis and characterisation
of transients and as input into a radial basis function network that is
trained to discriminate transients from pulse like to wave like.
Abstract: We derive simple sets of equations to describe the microwave response of a thin film of magnetized hydrogen plasma in the presence of carbon nanotubes, which were grown by ironcatalyzed high-pressure disproportionation (HiPco). By considering the interference effects due to multiple reflections between thin plasma film interfaces, we present the effects of the continuously changing external magnetic field and plasma parameters on the reflected power, absorbed power, and transmitted power in the system. The simulation results show that the interference effects play an important role in the reflectance, transmittance and absorptance of microwave radiation at the magnetized plasma slab. As a consequence, the interference effects lead to a sinusoidal variation of the reflected intensity and can greatly reduce the amount of reflection power, but the absorption power increases.
Abstract: Speckle phenomena results from when coherent
radiation is reflected from a rough surface. Characterizing the speckle
strongly depends on the measurement condition and experimental
setup. In this paper we report the experimental results produced with
different parameters in the setup. We investigated the factors which
affects the speckle contrast, such as, F-number, gamma value and
exposure time of the camera, rather than geometric factors like the
distance between the projector lens to the screen, the viewing distance,
etc. The measurement results show that the speckle contrast decreases
by decreasing F-number, by increasing gamma value, and slightly
affects by exposure time of the camera and the gain value of the
camera.
Abstract: Soils are normally dried in either a convection oven or stove. Laboratory moisture content testing indicated that the typical drying durations for a convection oven were, 24 hours. The purpose of this study was to determine the accuracy and soil drying duration of both, moisture content and liquid limit using microwave radiation. The soils were tested with both, convection and microwave ovens. The convection oven was considered to produce the true values for both, natural moisture content and liquid limit of soils; it was, therefore, used as a basis for comparison for the results of the microwave ovens. The samples used in this study were obtained from different projects of Consulting Engineering Bureau of College of Engineering of Sulaimani University. These samples were collected from different locations and at the different depths and consist mostly of brown and light brown clay and silty clay. A total of 102 samples were prepared. 26 of them were tested for natural moisture determination, while the other 76 were used for liquid limits determination
Abstract: This paper investigates the application of large scale (LS-PV) two-axis tracking photovoltaic power plant in Al-Jagbob, Libya. A 50MW PV-grid connected (two-axis tracking) power plant design in Al-Jagbob, Libya has been carried out presently. A hetero-junction with intrinsic thin layer (HIT) type PV module has been selected and modeled. A Microsoft Excel-VBA program has been constructed to compute slope radiation, dew-point, sky temperature, and then cell temperature, maximum power output and module efficiency for this system, for tracking system. The results for energy production show that the total energy output is 128.5 GWh/year. The average module efficiency is 16.6%. The electricity generation capacity factor (CF) and solar capacity factor (SCF) were found to be 29.3% and 70.4% respectively. A 50MW two axis tracking power plant with a total energy output of 128.5 GWh/year would reduce CO2 pollution by 85,581 tonnes of each year. The payback time for the proposed LS-PV photovoltaic power plant was found to be 4 years.
Abstract: A novel PDE solver using the multidimensional wave
digital filtering (MDWDF) technique to achieve the solution of a 2D
seismic wave system is presented. In essence, the continuous physical
system served by a linear Kirchhoff circuit is transformed to an
equivalent discrete dynamic system implemented by a MD wave
digital filtering (MDWDF) circuit. This amounts to numerically
approximating the differential equations used to describe elements of a
MD passive electronic circuit by a grid-based difference equations
implemented by the so-called state quantities within the passive
MDWDF circuit. So the digital model can track the wave field on a
dense 3D grid of points. Details about how to transform the continuous
system into a desired discrete passive system are addressed. In
addition, initial and boundary conditions are properly embedded into
the MDWDF circuit in terms of state quantities. Graphic results have
clearly demonstrated some physical effects of seismic wave (P-wave
and S–wave) propagation including radiation, reflection, and
refraction from and across the hard boundaries. Comparison between
the MDWDF technique and the finite difference time domain (FDTD)
approach is also made in terms of the computational efficiency.
Abstract: We investigated oxidative DNA damage caused by
radio frequency radiation using 8-oxo-7, 8-dihydro-2'-
deoxyguanosine (8-oxodG) generated in mice tissues after exposure
to 900 MHz mobile phone radio frequency in three independent
experiments. The RF was generated by a Global System for Mobile
Communication (GSM) signal generator. The radio frequency field
was adjusted to 25 V/m. The whole body specific absorption rate
(SAR) was 1.0 W/kg. Animals were exposed to this field for 30 min
daily for 30 days. 24 h post-exposure, blood serum, brain and spleen
were removed and DNA was isolated. Enzyme-linked
immunosorbent assay (ELISA) was used to measure 8-oxodG
concentration. All animals survived the whole experimental period.
The body weight of animals did not change significantly at the end of
the experiment. No statistically significant differences observed in
the levels of oxidative stress. Our results are not in favor of the
hypothesis that 900 MHz RF induces oxidative damage.
Abstract: Thermal behavior of fuel channel under loss of coolant accident (LOCA) is a major concern for nuclear reactor safety. LOCA along with failure of emergency cooling water system (ECC) may leads to mechanical deformations like sagging and ballooning. In order to understand the phenomenon an experiment has been carried out using 19 pin fuel element simulator. Main purpose of the experiment was to trace temperature profiles over the pressure tube, calandria tube and clad tubes of Indian Pressurized Heavy Water Reactor (IPHWR) under symmetrical and asymmetrical heat-up conditions. For simulating the fully voided scenario, symmetrical heating of pressure was carried out by injecting 13.2 KW (2 % of nominal power) to all the 19 pins and the temperatures of pressure tube, calandria tube and clad tubes were measured. During symmetrical heating the sagging of fuel channel was initiated at 460 °C and the highest temperature attained by PT was 650 °C . The decay heat from clad tubes was dissipated to moderator mainly by radiation and natural convection. The highest temperature of 680 °C was observed over the outer ring of clad tubes of fuel simulator. Again, to simulate partially voided condition, asymmetrical heating of pressure was carried out by supplying 8.0 kW power to upper 8 pins of fuel simulator and temperature profiles were measured. Along the circumference of pressure tube (PT) the highest temperature difference of 320 °C was observed, which highlights the magnitude of thermal stresses under partially voided conditions.