Abstract: Temperature, relative humidity and overhygroscopic
moisture fields in a sandstone wall provided with interior thermal
insulation were calculated in order to assess the hygric performance
of the retrofitted wall. Computational simulations showed that during
the time period of 10 years which was subject of investigation no
overhygroscopic moisture appeared in the analyzed building
envelope so that it performed in a satisfactory way from the hygric
point of view.
Abstract: Combined experimental and computational analysis of
hygrothermal performance of an interior thermal insulation system
applied on a brick wall is presented in the paper. In the experimental
part, the functionality of the insulation system is tested at simulated
difference climate conditions using a semi-scale device. The
measured temperature and relative humidity profiles are used for the
calibration of computer code HEMOT that is finally applied for a
long-term hygrothermal analysis of the investigated structure.