Abstract: We study dynamic instability in high-rise steel moment
resisting frames (SMRFs) subjected to synthetic long-period ground
motions caused by hypothetical huge subduction earthquakes. Since
long duration as well as long dominant periods is a characteristic of
long-period ground motions, interstory drifts may enter the negative
postyield stiffness range many times when high-rise buildings are
subjected to long-period ground motions. Through the case studies of
9 high-rise SMRFs designed in accordance with the Japanese design
practice in 1980s, we demonstrate that drifting, or accumulation of
interstory drifts in one direction, occurs at the lower stories of the
SMRFs, if their natural periods are close to the dominant periods of the
long-period ground motions. The drifting led to residual interstory
drift ratio over 0.01, or to collapse if the design base shear was small.
Abstract: Analytical seismic response of multi-story building
supported on base isolation system is investigated under real
earthquake motion. The superstructure is idealized as a shear type
flexible building with lateral degree-of-freedom at each floor. The
force-deformation behaviour of the isolation system is modelled by
the bi-linear behaviour which can be effectively used to model all
isolation systems in practice. The governing equations of motion of
the isolated structural system are derived. The response of the system
is obtained numerically by step-by-method under three real recorded
earthquake motions and pulse motions associated in the near-fault
earthquake motion. The variation of the top floor acceleration, interstory
drift, base shear and bearing displacement of the isolated
building is studied under different initial stiffness of the bi-linear
isolation system. It was observed that the high initial stiffness of the
isolation system excites higher modes in base-isolated structure and
generate floor accelerations and story drift. Such behaviour of the
base-isolated building especially supported on sliding type of
isolation systems can be detrimental to sensitive equipment installed
in the building. On the other hand, the bearing displacement and base
shear found to reduce marginally with the increase of the initial
stiffness of the initial stiffness of the isolation system. Further, the
above behaviour of the base-isolated building was observed for
different parameters of the bearing (i.e. post-yield stiffness and
characteristic strength) and earthquake motions (i.e. real time history
as well as pulse type motion).