Abstract: Robotic surgery is used to enhance minimally invasive
surgical procedure. It provides greater degree of freedom for surgical
tools but lacks of haptic feedback system to provide sense of touch to
the surgeon. Surgical robots work on master-slave operation, where
user is a master and robotic arms are the slaves. Current, surgical
robots provide precise control of the surgical tools, but heavily rely
on visual feedback, which sometimes cause damage to the inner
organs. The goal of this research was to design and develop a realtime
Simulink based robotic system to study force feedback
mechanism during instrument-object interaction. Setup includes three
VelmexXSlide assembly (XYZ Stage) for three dimensional
movement, an end effector assembly for forceps, electronic circuit for
four strain gages, two Novint Falcon 3D gaming controllers,
microcontroller board with linear actuators, MATLAB and Simulink
toolboxes. Strain gages were calibrated using Imada Digital Force
Gauge device and tested with a hard-core wire to measure
instrument-object interaction in the range of 0-35N. Designed
Simulink model successfully acquires 3D coordinates from two
Novint Falcon controllers and transfer coordinates to the XYZ stage
and forceps. Simulink model also reads strain gages signal through
10-bit analog to digital converter resolution of a microcontroller
assembly in real time, converts voltage into force and feedback the
output signals to the Novint Falcon controller for force feedback
mechanism. Experimental setup allows user to change forward
kinematics algorithms to achieve the best-desired movement of the
XYZ stage and forceps. This project combines haptic technology
with surgical robot to provide sense of touch to the user controlling
forceps through machine-computer interface.
Abstract: In this paper, the feasibility of using machine vision to assess task completion in a surgical intervention is investigated, with the aim of incorporating vision based inspection in robotic surgery systems. The visually rich operative field presents a good environment for the development of automated visual inspection techniques in these systems, for a more comprehensive approach when performing a surgical task. As a proof of concept, machine vision techniques were used to distinguish the two possible outcomes i.e. satisfactory or unsatisfactory, of three primary surgical tasks involved in creating a burr hole in the skull, namely incision, retraction, and drilling. Encouraging results were obtained for the three tasks under consideration, which has been demonstrated by experiments on cadaveric pig heads. These findings are suggestive for the potential use of machine vision to validate successful task completion in robotic surgery systems. Finally, the potential of using machine vision in the operating theatre, and the challenges that must be addressed, are identified and discussed.
Abstract: One of the major disadvantages of the minimally
invasive surgery (MIS) is the lack of tactile feedback to the surgeon.
In order to identify and avoid any damage to the grasped complex
tissue by endoscopic graspers, it is important to measure the local
softness of tissue during MIS. One way to display the measured
softness to the surgeon is a graphical method. In this paper, a new
tactile sensor has been reported. The tactile sensor consists of an
array of four softness sensors, which are integrated into the jaws of a
modified commercial endoscopic grasper. Each individual softness
sensor consists of two piezoelectric polymer Polyvinylidene Fluoride
(PVDF) films, which are positioned below a rigid and a compliant
cylinder. The compliant cylinder is fabricated using a micro molding
technique. The combination of output voltages from PVDF films is
used to determine the softness of the grasped object. The theoretical
analysis of the sensor is also presented.
A method has been developed with the aim of reproducing the
tactile softness to the surgeon by using a graphical method. In this
approach, the proposed system, including the interfacing and the data
acquisition card, receives signals from the array of softness sensors.
After the signals are processed, the tactile information is displayed
by means of a color coding method. It is shown that the degrees of
softness of the grasped objects/tissues can be visually differentiated
and displayed on a monitor.
Abstract: The use of machine vision to inspect the outcome of
surgical tasks is investigated, with the aim of incorporating this
approach in robotic surgery systems. Machine vision is a non-contact
form of inspection i.e. no part of the vision system is in direct contact
with the patient, and is therefore well suited for surgery where
sterility is an important consideration,. As a proof-of-concept, three
primary surgical tasks for a common neurosurgical procedure were
inspected using machine vision. Experiments were performed on
cadaveric pig heads to simulate the two possible outcomes i.e.
satisfactory or unsatisfactory, for tasks involved in making a burr
hole, namely incision, retraction, and drilling. We identify low level
image features to distinguish the two outcomes, as well as report on
results that validate our proposed approach. The potential of using
machine vision in a surgical environment, and the challenges that
must be addressed, are identified and discussed.
Abstract: Sensorized instruments that accurately measure the interaction forces (between biological tissue and instrument endeffector) during surgical procedures offer surgeons a greater sense of immersion during minimally invasive robotic surgery. Although there is ongoing research into force measurement involving surgical graspers little corresponding effort has been carried out on the measurement of forces between scissor blades and tissue. This paper presents the design and development of a force measurement test apparatus, which will serve as a sensor characterization and evaluation platform. The primary aim of the experiments is to ascertain whether the system can differentiate between tissue samples with differing mechanical properties in a reliable, repeatable manner. Force-angular displacement curves highlight trends in the cutting process as well the forces generated along the blade during a cutting procedure. Future applications of the test equipment will involve the assessment of new direct force sensing technologies for telerobotic surgery.