Abstract: This paper presents the development of a wavelet
based algorithm, for distinguishing between magnetizing inrush
currents and power system fault currents, which is quite adequate,
reliable, fast and computationally efficient tool. The proposed
technique consists of a preprocessing unit based on discrete wavelet
transform (DWT) in combination with an artificial neural network
(ANN) for detecting and classifying fault currents. The DWT acts as
an extractor of distinctive features in the input signals at the relay
location. This information is then fed into an ANN for classifying
fault and magnetizing inrush conditions. A 220/55/55 V, 50Hz
laboratory transformer connected to a 380 V power system were
simulated using ATP-EMTP. The DWT was implemented by using
Matlab and Coiflet mother wavelet was used to analyze primary
currents and generate training data. The simulated results presented
clearly show that the proposed technique can accurately discriminate
between magnetizing inrush and fault currents in transformer
protection.
Abstract: Cooperative diversity (CD) has been adopted in many communication systems because it helps in improving performance of the wireless communication systems with the help of the relays that emulate the multiple antenna terminals. This work aims to provide the derivation of the performance analysis expressions of the multiuser diversity (MUD) in the two-hop cooperative multi-relay wireless networks (TCMRNs). Considering the work analysis, we provide analytically the derivation of a closed form expression of the two most commonly used performance metrics namely, the outage probability and the symbol error probability (SEP) for the fixed decode-and-forward (FDF) protocol with MUD.
Abstract: This paper describes the smart energy monitoring system with a wireless sensor network for monitoring of electrical usage in smart house. Proposed system is composed of wireless plugs and energy control wallpad server. The wireless plug integrates an AC power socket, a relay to switch the socket ON/OFF, a Hall effect sensor to sense current of load appliance and a Kmote. The Kmote is a wireless communication interface based on TinyOS. We evaluated wireless plug in a laboratory, analyzed and presented energy consumption data from electrical appliances for 3 months in home.
Abstract: Personnel protection devices are cardinal in safety hazard applications. They are widely used in home, office and in industry environments to reduce the risk of lethal shock to human being and equipment safety. This paper briefly reviews various personnel protection devices also describes the basic working principle of conventional ground fault circuit interrupter (GFCI) or ground fault isolator (GFI), its disadvantages and ways to overcome the disadvantages with solid-state relay (SSR) based GFI with ultrafast response up on fault implemented in printed circuit board. This solid state GFI comprises discrete MOSFET based alternating current (AC) switches, linear optical amplifier, photovoltaic isolator and sense resistor. In conventional GFI, current transformer is employed as a sensing element to detect the difference in current flow between live and neutral conductor. If there is no fault in equipment powered through GFI, due to insulation failure of internal wires and windings of motors, both live and neutral currents will be equal in magnitude and opposite in phase.
Abstract: In order to achieve better road utilization and traffic
efficiency, there is an urgent need for a travel information delivery
mechanism to assist the drivers in making better decisions in the
emerging intelligent transportation system applications. In this paper,
we propose a relayed multicast scheme under heterogeneous networks
for this purpose. In the proposed system, travel information consisting
of summarized traffic conditions, important events, real-time traffic
videos, and local information service contents is formed into layers
and multicasted through an integration of WiMAX infrastructure and
Vehicular Ad hoc Networks (VANET). By the support of adaptive
modulation and coding in WiMAX, the radio resources can be
optimally allocated when performing multicast so as to dynamically
adjust the number of data layers received by the users. In addition to
multicast supported by WiMAX, a knowledge propagation and
information relay scheme by VANET is designed. The experimental
results validate the feasibility and effectiveness of the proposed
scheme.
Abstract: Over Current Relays (OCRs) and Directional Over Current Relays (DOCRs) are widely used for the radial protection and ring sub transmission protection systems and for distribution systems. All previous work formulates the DOCR coordination problem either as a Non-Linear Programming (NLP) for TDS and Ip or as a Linear Programming (LP) for TDS using recently a social behavior (Particle Swarm Optimization techniques) introduced to the work. In this paper, a Modified Particle Swarm Optimization (MPSO) technique is discussed for the optimal settings of DOCRs in power systems as a Non-Linear Programming problem for finding Ip values of the relays and for finding the TDS setting as a linear programming problem. The calculation of the Time Dial Setting (TDS) and the pickup current (Ip) setting of the relays is the core of the coordination study. PSO technique is considered as realistic and powerful solution schemes to obtain the global or quasi global optimum in optimization problem.
Abstract: Internet Protocol version 4 (IPv4) address is decreasing and a rapid transition method to the next generation IP address (IPv6) should be established. This study aims to evaluate and select the best performance of the IPv6 address network transitionmechanisms, such as IPv4/IPv6 dual stack, transport Relay Translation (TRT) and Reverse Proxy with additional features. It is also aim to prove that faster access can be done while ensuring optimal usage of available resources used during the test and actual implementation. This study used two test methods such asInternet Control Message Protocol (ICMP)ping and ApacheBenchmark (AB) methodsto evaluate the performance.Performance metrics for this study include aspects ofaverageaccessin one second,time takenfor singleaccess,thedata transfer speed and the costof additional requirements.Reverse Proxy with Caching featureis the most efficientmechanism because of it simpler configurationandthe best performerfrom the test conducted.
Abstract: In this paper, we propose an effective relay
communication for layered video transmission as an alternative to
make the most of limited resources in a wireless communication
network where loss often occurs. Relaying brings stable multimedia
services to end clients, compared to multiple description coding
(MDC). Also, retransmission of only parity data about one or more
video layer using channel coder to the end client of the relay device is
paramount to the robustness of the loss situation. Using these
methods in resource-constrained environments, such as real-time user
created content (UCC) with layered video transmission, can provide
high-quality services even in a poor communication environment.
Minimal services are also possible. The mathematical analysis shows
that the proposed method reduced the probability of GOP loss rate
compared to MDC and raptor code without relay. The GOP loss rate
is about zero, while MDC and raptor code without relay have a GOP
loss rate of 36% and 70% in case of 10% frame loss rate.
Abstract: Development of levels of service in municipal context
is a flexible vehicle to assist in performing quality-cost trade-off
analysis for municipal services. This trade-off depends on the
willingness of a community to pay as well as on the condition of the
assets. Community perspective of the performance of an asset from
service point of view may be quite different from the municipality
perspective of the performance of the same asset from condition
point of view. This paper presents a three phased level of service
based methodology for water mains that consists of :1)development
of an Analytical Hierarchy model of level of service 2) development
of Fuzzy Weighted Sum model of water main condition index and 3)
deriving a Fuzzy logic based function that maps level of service to
asset condition index. This mapping will assist asset managers in
quantifying condition improvement requirement to meet service
goals and to make more informed decisions on interventions and
relayed priorities.
Abstract: Nodes in mobile Ad Hoc Network (MANET) do not
rely on a central infrastructure but relay packets originated by other
nodes. Mobile ad hoc networks can work properly only if the
participating nodes collaborate in routing and forwarding. For
individual nodes it might be advantageous not to collaborate, though.
In this conceptual paper we propose a new approach based on
relationship among the nodes which makes them to cooperate in an
Adhoc environment. The trust unit is used to calculate the trust
values of each node in the network. The calculated trust values are
being used by the relationship estimator to determine the relationship
status of nodes. The proposed enhanced protocol was compared with
the standard DSR protocol and the results are analyzed using the
network simulator-2.
Abstract: The important issue considered in the widespread deployment of Wireless Sensor Networks (WSNs) is an efficiency of the energy consumption. In this paper, we present a study of the optimal relay station planning problems using Binary Integer Linear Programming (BILP) model to minimize the energy consumption in WSNs. Our key contribution is that the proposed model not only ensures the required network lifetime but also guarantees the radio connectivity at high level of communication quality. Specially, we take into account effects of noise, signal quality limitation and bit error rate characteristics. Numerical experiments were conducted in various network scenarios. We analyzed the effects of different sensor node densities and distribution on the energy consumption.
Abstract: The issue of real-time and reliable report delivery is extremely important for taking effective decision in a real world mission critical Wireless Sensor Network (WSN) based application. The sensor data behaves differently in many ways from the data in traditional databases. WSNs need a mechanism to register, process queries, and disseminate data. In this paper we propose an architectural framework for data placement and management. We propose a reliable and real time approach for data placement and achieving data integrity using self organized sensor clusters. Instead of storing information in individual cluster heads as suggested in some protocols, in our architecture we suggest storing of information of all clusters within a cell in the corresponding base station. For data dissemination and action in the wireless sensor network we propose to use Action and Relay Stations (ARS). To reduce average energy dissipation of sensor nodes, the data is sent to the nearest ARS rather than base station. We have designed our architecture in such a way so as to achieve greater energy savings, enhanced availability and reliability.
Abstract: The asymmetric trafc between uplink and downlink
over recent mobile communication systems has been conspicuous because
of providing new communication services. This paper proposes
an asymmetric trafc accommodation scheme adopting a multihop
cooperative transmission technique for CDMA/FDD cellular networks.
The proposed scheme employs the cooperative transmission
technique in the already proposed downlink multihop transmissions
for the accommodation of the asymmetric trafc, which utilizes
the vacant uplink band for the downlink relay transmissions. The
proposed scheme reduces the transmission power at the downlink
relay transmissions and then suppresses the interference to the uplink
communications, and thus, improves the uplink performance. The
proposed scheme is evaluated by computer simulation and the results
show that it can achieve better throughput performance.
Abstract: The most common cause of power transformer failures
is mechanical defect brought about by excessive vibration, which is
formed by the combination of multiples of a frequency of 120 Hz. In
this paper, the types of mechanical exciting forces applied to the
power transformer were classified, and the mechanical damage
mechanism of the power transformer was identified using the
vibration transfer route to the machine or structure. The general
effects of 120 Hz-vibration on the enclosure, bushing, Buchholz
relay, pressure release valve and tap changer of the transformer were
also examined.
Abstract: The distance protection mainly the impedance relay which is considered as the main protection for transmission lines can be subjected to impedance measurement error which is, mainly, due to the fault resistance and to the power fluctuation. Thus, the impedance relay may not operate for a short circuit at the far end of the protected line (case of the under reach) or operates for a fault beyond its protected zone (case of overreach). In this paper, an approach to fault detection by a distance protection, which distinguishes between the faulty conditions and the effect of overload operation mode, has been developed. This approach is based on the symmetrical components; mainly the negative sequence, and it is taking into account both the effect of fault resistance and the overload situation which both have an effect upon the reliability of the protection in terms of dependability for the former and security for the latter.
Abstract: This paper deals with wireless relay communication
systems in which multiple sources transmit information to the
destination node by the help of multiple relays. We consider a
signal forwarding technique based on the minimum mean-square
error (MMSE) approach with multiple antennas for each relay. A
source-relay-destination joint design strategy is proposed with power
constraints at the destination and the source nodes. Simulation results
confirm that the proposed joint design method improves the average
MSE performance compared with that of conventional MMSE relaying
schemes.
Abstract: Relay based communication has gained considerable importance in the recent years. In this paper we find the end-toend statistics of a two hop non-regenerative relay branch, each hop being Nakagami-m faded. Closed form expressions for the probability density functions of the signal envelope at the output of a selection combiner and a maximal ratio combiner at the destination node are also derived and analytical formulations are verified through computer simulation. These density functions are useful in evaluating the system performance in terms of bit error rate and outage probability.
Abstract: A new and cost effective robotic device was designed
for remote tele surgery using dual tone multi frequency technology
(DTMF). Tele system with Dual Tone Multiple Frequency has a large
capability in sending and receiving of data in hardware and software.
The robot consists of DC motors for arm movements and it is
controlled manually through a mobile phone through DTMF
Technology. The system enables the surgeon from base station to
send commands through mobile phone to the patient’s robotic system
which includes two robotic arms that translate the input into actual
instrument manipulation. A mobile phone attached to the
microcontroller 8051 which can activate robot through relays. The
Remote robot-assisted tele surgery eliminates geographic constraints
for getting surgical expertise where it is needed and allows an expert
surgeon to teach or proctor the performance of surgical technique by
real-time intervention.
Abstract: To determine the presence and location of faults in a transmission by the adaptation of protective distance relay based on the measurement of fixed settings as line impedance is achieved by several different techniques. Moreover, a fast, accurate and robust technique for real-time purposes is required for the modern power systems. The appliance of radial basis function neural network in transmission line protection is demonstrated in this paper. The method applies the power system via voltage and current signals to learn the hidden relationship presented in the input patterns. It is experiential that the proposed technique is competent to identify the particular fault direction more speedily. System simulations studied show that the proposed approach is able to distinguish the direction of a fault on a transmission line swiftly and correctly, therefore suitable for the real-time purposes.
Abstract: In power systems, protective relays must filter their
inputs to remove undesirable quantities and retain signal quantities of
interest. This job must be performed accurate and fast. A new
method for filtering the undesirable components such as DC and
harmonic components associated with the fundamental system
signals. The method is s based on a dynamic filtering algorithm. The
filtering algorithm has many advantages over some other classical
methods. It can be used as dynamic on-line filter without the need of
parameters readjusting as in the case of classic filters. The proposed
filter is tested using different signals. Effects of number of samples
and sampling window size are discussed. Results obtained are
presented and discussed to show the algorithm capabilities.