Abstract: A fluidized catalytic cracking unit (FCCU) is one of the effective units in many refineries. Modeling and optimization of FCCU were done by many researchers in past decades, but in this research, comparison between post- and oxy-combustion was studied in the regenerator-FCCU. Therefore, a simplified mathematical model was derived by doing mass/heat balances around both reactor and regenerator. A state space analysis was employed to show effects of the flow rates variables such as air, feed, spent catalyst, regenerated catalyst and flue gas on the output variables. The main aim of studying dynamic responses is to figure out the most influencing variables that affect both reactor/regenerator temperatures; also, finding the upper/lower limits of the influencing variables to ensure that temperatures of the reactors and regenerator work within normal operating conditions. Therefore, those values will be used as side constraints in the optimization technique to find appropriate operating regimes. The objective functions were modeled to be maximizing the energy in the reactor while minimizing the energy consumption in the regenerator. In conclusion, an oxy-combustion process can be used instead of a post-combustion one.
Abstract: Fault diagnosis of Linear Parameter-Varying (LPV)
system using an adaptive Kalman filter is proposed. The LPV model
is comprised of scheduling parameters, and the emulator parameters.
The scheduling parameters are chosen such that they are capable of
tracking variations in the system model as a result of changes in the
operating regimes. The emulator parameters, on the other hand,
simulate variations in the subsystems during the identification phase
and have negligible effect during the operational phase. The nominal
model and the influence vectors, which are the gradient of the feature
vector respect to the emulator parameters, are identified off-line from
a number of emulator parameter perturbed experiments. A Kalman
filter is designed using the identified nominal model. As the system
varies, the Kalman filter model is adapted using the scheduling
variables. The residual is employed for fault diagnosis. The
proposed scheme is successfully evaluated on simulated system as
well as on a physical process control system.
Abstract: The paper analyzes the large power transformer unit regimes, indicating the criteria for the management of the voltage operating conditions, as well as the change in the operating conditions with the load connected to the secondary winding of the transformer unit. Further, the paper presents the software application for the evaluation of the transformer unit operation under different conditions. The software application was developed by means of virtual instrumentation.