Abstract: In this paper, a spatial multiple-kernel fuzzy C-means (SMKFCM) algorithm is introduced for segmentation problem. A linear combination of multiples kernels with spatial information is used in the kernel FCM (KFCM) and the updating rules for the linear coefficients of the composite kernels are derived as well. Fuzzy cmeans (FCM) based techniques have been widely used in medical image segmentation problem due to their simplicity and fast convergence. The proposed SMKFCM algorithm provides us a new flexible vehicle to fuse different pixel information in medical image segmentation and detection of MR images. To evaluate the robustness of the proposed segmentation algorithm in noisy environment, we add noise in medical brain tumor MR images and calculated the success rate and segmentation accuracy. From the experimental results it is clear that the proposed algorithm has better performance than those of other FCM based techniques for noisy medical MR images.
Abstract: One of the most important challenging factors in
medical images is nominated as noise. Image denoising refers to the
improvement of a digital medical image that has been infected by
Additive White Gaussian Noise (AWGN). The digital medical image
or video can be affected by different types of noises. They are
impulse noise, Poisson noise and AWGN. Computed tomography
(CT) images are subjects to low quality due to the noise. Quality of
CT images is dependent on absorbed dose to patients directly in such
a way that increase in absorbed radiation, consequently absorbed
dose to patients (ADP), enhances the CT images quality. In this
manner, noise reduction techniques on purpose of images quality
enhancement exposing no excess radiation to patients is one the
challenging problems for CT images processing. In this work, noise
reduction in CT images was performed using two different
directional 2 dimensional (2D) transformations; i.e., Curvelet and
Contourlet and Discrete Wavelet Transform (DWT) thresholding
methods of BayesShrink and AdaptShrink, compared to each other
and we proposed a new threshold in wavelet domain for not only
noise reduction but also edge retaining, consequently the proposed
method retains the modified coefficients significantly that result good
visual quality. Data evaluations were accomplished by using two
criterions; namely, peak signal to noise ratio (PSNR) and Structure
similarity (Ssim).
Abstract: Image segmentation plays an important role in
medical imaging applications. Therefore, accurate methods are
needed for the successful segmentation of medical images for
diagnosis and detection of various diseases. In this paper, we have
used maximum entropy to achieve image segmentation. Maximum
entropy has been calculated using Shannon, Renyi and Tsallis
entropies. This work has novelty based on the detection of skin lesion
caused by the bite of a parasite called Sand Fly causing the disease is
called Cutaneous Leishmaniasis.
Abstract: Content Based Image Retrieval (CBIR) coupled with
Case Based Reasoning (CBR) is a paradigm that is becoming
increasingly popular in the diagnosis and therapy planning of medical
ailments utilizing the digital content of medical images. This paper
presents a survey of some of the promising approaches used in the
detection of abnormalities in retina images as well in
mammographic screening and detection of regions of interest
in MRI scans of the brain. We also describe our proposed
algorithm to detect hard exudates in fundus images of the
retina of Diabetic Retinopathy patients.
Abstract: The fuzzy composition of objects depicted in images
acquired through MR imaging or the use of bio-scanners has often
been a point of controversy for field experts attempting to effectively
delineate between the visualized objects. Modern approaches in
medical image segmentation tend to consider fuzziness as a
characteristic and inherent feature of the depicted object, instead of
an undesirable trait. In this paper, a novel technique for efficient
image retrieval in the context of images in which segmented objects
are either crisp or fuzzily bounded is presented. Moreover, the
proposed method is applied in the case of multiple, even conflicting,
segmentations from field experts. Experimental results demonstrate
the efficiency of the suggested method in retrieving similar objects
from the aforementioned categories while taking into account the
fuzzy nature of the depicted data.
Abstract: The process in which the complementary information from multiple images is integrated to provide composite image that contains more information than the original input images is called image fusion. Medical image fusion provides useful information from multimodality medical images that provides additional information to the doctor for diagnosis of diseases in a better way. This paper represents the wavelet based medical image fusion algorithm on different multimodality medical images. In order to fuse the medical images, images are decomposed using Redundant Wavelet Transform (RWT). The high frequency coefficients are convolved with morphological operator followed by the maximum-selection (MS) rule. The low frequency coefficients are processed by MS rule. The reconstructed image is obtained by inverse RWT. The quantitative measures which includes Mean, Standard Deviation, Average Gradient, Spatial frequency, Edge based Similarity Measures are considered for evaluating the fused images. The performance of this proposed method is compared with Pixel averaging, PCA, and DWT fusion methods. When compared with conventional methods, the proposed framework provides better performance for analysis of multimodality medical images.
Abstract: Medical Image fusion plays a vital role in medical
field to diagnose the brain tumors which can be classified as benign
or malignant. It is the process of integrating multiple images of the
same scene into a single fused image to reduce uncertainty and
minimizing redundancy while extracting all the useful information
from the source images. Fuzzy logic is used to fuse two brain MRI
images with different vision. The fused image will be more
informative than the source images. The texture and wavelet features
are extracted from the fused image. The multilevel Adaptive Neuro
Fuzzy Classifier classifies the brain tumors based on trained and
tested features. The proposed method achieved 80.48% sensitivity,
99.9% specificity and 99.69% accuracy. Experimental results
obtained from fusion process prove that the use of the proposed
image fusion approach shows better performance while compared
with conventional fusion methodologies.
Abstract: Medical image analysis is one of the great effects of computer image processing. There are several processes to analysis the medical images which the segmentation process is one of the challenging and most important step. In this paper the segmentation method proposed in order to segment the dental radiograph images. Thresholding method has been applied to simplify the images and to morphologically open binary image technique performed to eliminate the unnecessary regions on images. Furthermore, horizontal and vertical integral projection techniques used to extract the each individual tooth from radiograph images. Segmentation process has been done by applying the level set method on each extracted images. Nevertheless, the experiments results by 90% accuracy demonstrate that proposed method achieves high accuracy and promising result.
Abstract: Medical image is an integral part of e-health care and e-diagnosis system. Medical image watermarking is widely used to protect patients’ information from malicious alteration and manipulation. The watermarked medical images are transmitted over the internet among patients, primary and referred physicians. The images are highly prone to corruption in the wireless transmission medium due to various noises, deflection, and refractions. Distortion in the received images leads to faulty watermark detection and inappropriate disease diagnosis. To address the issue, this paper utilizes error correction code (ECC) with (8, 4) Hamming code in an existing watermarking system. In addition, we implement the high complex ECC on a graphics processing units (GPU) to accelerate and support real-time requirement. Experimental results show that GPU achieves considerable speedup over the sequential CPU implementation, while maintaining 100% ECC efficiency.
Abstract: Reversible watermarking is a special branch of image watermarking, that is able to recover the original image after extracting the watermark from the image. In this paper, an adaptive prediction-based reversible watermarking scheme is presented, in order to increase the payload capacity of MRI medical images. The scheme divides the image into two parts, Region of Interest (ROI) and Region of Non-Interest (RONI). Two bits are embedded in each embeddable pixel of RONI and one bit is embedded in each embeddable pixel of ROI. The experimental results demonstrate that the proposed scheme is able to achieve high embedding capacity. This is mainly caused by two reasons. First, the pixels that were excluded from data embedding due to overflow/underflow are used for data embedding. Second, large location map that need to be added to watermark data as overhead is eliminated and thus lower data embedding capacity is prevented. Moreover, the scheme provides good visual quality to the watermarked image.
Abstract: There is a growing interest in the use of ultrasonic speckle tracking for biomedical image formation of tissue deformation. Speckle tracking is angle independent and has an ability to differentiate soft tissue into benign and malignant regions. In this paper a simulation model for dynamic ultrasound scatterer is presented. The model composes Field-II ultrasonic scatterers and FEM (ANSYS-11) nodes as a regional tissue deformation. A performance evaluation is presented on axial displacement and strain fields estimation of a uniformly elastic model, using speckle tracking based 1D cross-correlation of optimally segmented pre and post-deformation frames. Optimum correlation window length is investigated in terms of highest signal-to-noise ratio (SNR) for a selected region of interest of a smoothed displacement field. Finally, gradient based strain field of both smoothed and non-smoothed displacement fields are compared. Simulation results from the model are shown to compare favorably with FEM results.
Abstract: In this paper problem of edge detection in digital images is considered. Edge detection based on morphological operators was applied on two sets (brain & chest) ct images. Three methods of edge detection by applying line morphological filters with multi structures in different directions have been used. 3x3 filter for first method, 5x5 filter for second method, and 7x7 filter for third method. We had applied this algorithm on (13 images) under MATLAB program environment. In order to evaluate the performance of the above mentioned edge detection algorithms, standard deviation (SD) and peak signal to noise ratio (PSNR) were used for justification for all different ct images. The objective method and the comparison of different methods of edge detection, shows that high values of both standard deviation and PSNR values of edge detection images were obtained.
Abstract: The exponential increase in the volume of medical image database has imposed new challenges to clinical routine in maintaining patient history, diagnosis, treatment and monitoring. With the advent of data mining and machine learning techniques it is possible to automate and/or assist physicians in clinical diagnosis. In this research a medical image classification framework using data mining techniques is proposed. It involves feature extraction, feature selection, feature discretization and classification. In the classification phase, the performance of the traditional kNN k nearest neighbor classifier is improved using a feature weighting scheme and a distance weighted voting instead of simple majority voting. Feature weights are calculated using the interestingness measures used in association rule mining. Experiments on the retinal fundus images show that the proposed framework improves the classification accuracy of traditional kNN from 78.57 % to 92.85 %.
Abstract: This paper presents a customized deformable model
for the segmentation of abdominal and thoracic aortic aneurysms in
CTA datasets. An important challenge in reliably detecting aortic
aneurysm is the need to overcome problems associated with intensity
inhomogeneities and image noise. Level sets are part of an important
class of methods that utilize partial differential equations (PDEs) and
have been extensively applied in image segmentation. A Gaussian
kernel function in the level set formulation, which extracts the local
intensity information, aids the suppression of noise in the extracted
regions of interest and then guides the motion of the evolving contour
for the detection of weak boundaries. The speed of curve evolution
has been significantly improved with a resulting decrease in
segmentation time compared with previous implementations of level
sets. The results indicate the method is more effective than other
approaches in coping with intensity inhomogeneities.
Abstract: This paper used a fuzzy kohonen neural network for medical image segmentation. Image segmentation plays a important role in the many of medical imaging applications by automating or facilitating the diagnostic. The paper analyses the tumor by extraction of the features of (area, entropy, means and standard deviation).These measurements gives a description for a tumor.
Abstract: An early and accurate detection of Alzheimer's disease (AD) is an important stage in the treatment of individuals suffering from AD. We present an approach based on the use of structural magnetic resonance imaging (sMRI) phase images to distinguish between normal controls (NC), mild cognitive impairment (MCI) and AD patients with clinical dementia rating (CDR) of 1. Independent component analysis (ICA) technique is used for extracting useful features which form the inputs to the support vector machines (SVM), K nearest neighbour (kNN) and multilayer artificial neural network (ANN) classifiers to discriminate between the three classes. The obtained results are encouraging in terms of classification accuracy and effectively ascertain the usefulness of phase images for the classification of different stages of Alzheimer-s disease.
Abstract: Medical image segmentation based on image smoothing followed by edge detection assumes a great degree of importance in the field of Image Processing. In this regard, this paper proposes a novel algorithm for medical image segmentation based on vigorous smoothening by identifying the type of noise and edge diction ideology which seems to be a boom in medical image diagnosis. The main objective of this algorithm is to consider a particular medical image as input and make the preprocessing to remove the noise content by employing suitable filter after identifying the type of noise and finally carrying out edge detection for image segmentation. The algorithm consists of three parts. First, identifying the type of noise present in the medical image as additive, multiplicative or impulsive by analysis of local histograms and denoising it by employing Median, Gaussian or Frost filter. Second, edge detection of the filtered medical image is carried out using Canny edge detection technique. And third part is about the segmentation of edge detected medical image by the method of Normalized Cut Eigen Vectors. The method is validated through experiments on real images. The proposed algorithm has been simulated on MATLAB platform. The results obtained by the simulation shows that the proposed algorithm is very effective which can deal with low quality or marginal vague images which has high spatial redundancy, low contrast and biggish noise, and has a potential of certain practical use of medical image diagnosis.
Abstract: With the advance of multimedia and diagnostic
images technologies, the number of radiographic images is increasing
constantly. The medical field demands sophisticated systems for
search and retrieval of the produced multimedia document. This
paper presents an ongoing research that focuses on the semantic
content of radiographic image documents to facilitate semantic-based
radiographic image indexing and a retrieval system. The proposed
model would divide a radiographic image document, based on its
semantic content, and would be converted into a logical structure or
a semantic structure. The logical structure represents the overall
organization of information. The semantic structure, which is bound
to logical structure, is composed of semantic objects with
interrelationships in the various spaces in the radiographic image.
Abstract: The purpose of this work is to present a method for
rigid registration of medical images using 1D binary projections
when a part of one of the two images is missing. We use 1D binary
projections and we adjust the projection limits according to the
reduced image in order to perform accurate registration. We use the
variance of the weighted ratio as a registration function which we
have shown is able to register 2D and 3D images more accurately and
robustly than mutual information methods. The function is computed
explicitly for n=5 Chebyshev points in a [-9,+9] interval and it is
approximated using Chebyshev polynomials for all other points. The
images used are MR scans of the head. We find that the method is
able to register the two images with average accuracy 0.3degrees for
rotations and 0.2 pixels for translations for a y dimension of 156 with
initial dimension 256. For y dimension 128/256 the accuracy
decreases to 0.7 degrees for rotations and 0.6 pixels for translations.
Abstract: Medical image registration is the key technology in image guided radiation therapy (IGRT) systems. On the basis of the previous work on our IGRT prototype with a biorthogonal x-ray imaging system, we described a method focused on the 2D/2D rigid-body registration using multiresolution pyramid based mutual information in this paper. Three key steps were involved in the method : firstly, four 2D images were obtained including two x-ray projection images and two digital reconstructed radiographies(DRRs ) as the input for the registration ; Secondly, each pair of the corresponding x-ray image and DRR image were matched using multiresolution pyramid based mutual information under the ITK registration framework ; Thirdly, we got the final couch offset through a coordinate transformation by calculating the translations acquired from the two pairs of the images. A simulation example of a parotid gland tumor case and a clinical example of an anthropomorphic head phantom were employed in the verification tests. In addition, the influence of different CT slice thickness were tested. The simulation results showed that the positioning errors were 0.068±0.070, 0.072±0.098, 0.154±0.176mm along three axes which were lateral, longitudinal and vertical. The clinical test indicated that the positioning errors of the planned isocenter were 0.066, 0.07, 2.06mm on average with a CT slice thickness of 2.5mm. It can be concluded that our method with its verified accuracy and robustness can be effectively used in IGRT systems for patient setup.