Abstract: This paper presents a comprehensive survey of recent research studies to segment and classify brain MR (magnetic resonance) images in order to detect significant changes to brain ventricles. The paper also presents a general framework for detecting regions that atrophy, which can help neurologists in detecting and staging Alzheimer. Furthermore, a prototype was implemented to segment brain MR images in order to extract the region of interest (ROI) and then, a classifier was employed to differentiate between normal and abnormal brain tissues. Experimental results show that the proposed scheme can provide a reliable second opinion that neurologists can benefit from.
Abstract: In order to understand the auto-ignition process in a HCCI engine better, the influence of some important parameters on the auto-ignition is investigated. The inlet temperature, the inlet pressure, and the compression ratio were varied and their influence on the ignition delays and emission characteristics were studied. The inlet temperature was changed from 400 K to 460 K (in step of 15 K), the inlet pressure from 0.9 to 3 atm, while the compression ratio varied from 15 to 23. The fuel that was investigated is isooctane. The inlet temperature, the inlet pressure, and the compression ratio appeared to decrease the ignition delays, with the inlet pressure having the least influence and the compression ratio the most. The effect of these parameters on emissions’ characteristics were also investigated. Results indicate that increasing the compression ratio results in increasing the concentration of all the species.
Abstract: In the first decade of the twenty-first century, advanced imaging techniques began to be applied for neuroscience research. The Functional Magnetic Resonance Imaging (fMRI) is one of the most important and most used research techniques for the investigation of emotions, because of its ease to observe the brain areas that oxygenate when performing certain tasks. In this research, we make a review about the main research carried out on the influence of the emotions in the decision-making process that is exposed by using the fMRI.
Abstract: Neurological disorders are the most debilitating of manifestations seen in patients infected with HIV. The clinical profile of neurological manifestations in HIV patients has undergone a shift in recent years with opportunistic infections being controlled with combination anti-retroviral therapy and the advent of drugs which have higher central nervous system penetrability. The aim of this paper is to study the clinical, investigation profile and various neurological disorders in HIV patients on anti‐retroviral therapy. Fifty HIV patients with neurological manifestations were studied. A complete neurological examination including neurocognitive functioning using Montreal Cognitive Assessment and HIV Dementia scale were assessed. Apart from relevant investigations, CD4 count, cerebrovascular fluid analysis, computed tomography (CT) and magnetic resonance imaging (MRI) of brain were done whenever required. Neurocognitive disorders formed the largest group with 42% suffering from HIV associated Neurocognitive Disorders. Among them, asymptomatic neurocognitive impairment was seen in 28%; mild neurocognitive disorder in 12%, and 2% had HIV‐associated dementia. Opportunistic infections of the nervous system accounted for 32%, with meningitis being the most common. Four patients had space occupying lesions of central nervous system; four tuberculomas, and one toxoplasmosis. With the advent of highly active retroviral therapy, HIV patients have longer life spans with suppression of viral load leading to decrease in opportunistic infections of the nervous system. Neurocognitive disorders are now the most common neurological dysfunction seen and thus neurocognitive assessment must be done in all patients with HIV.
Abstract: Medical digital images usually have low resolution because of nature of their acquisition. Therefore, this paper focuses on zooming these images to obtain better level of information, required for the purpose of medical diagnosis. For this purpose, a strategy for selecting pixels in zooming operation is proposed. It is based on the principle of analog clock and utilizes a combination of point and neighborhood image processing. In this approach, the hour hand of clock covers the portion of image to be processed. For alignment, the center of clock points at middle pixel of the selected portion of image. The minute hand is longer in length, and is used to gain information about pixels of the surrounding area. This area is called neighborhood pixels region. This information is used to zoom the selected portion of the image. The proposed algorithm is implemented and its performance is evaluated for many medical images obtained from various sources such as X-ray, Computerized Tomography (CT) scan and Magnetic Resonance Imaging (MRI). However, for illustration and simplicity, the results obtained from a CT scanned image of head is presented. The performance of algorithm is evaluated in comparison to various traditional algorithms in terms of Peak signal-to-noise ratio (PSNR), maximum error, SSIM index, mutual information and processing time. From the results, the proposed algorithm is found to give better performance than traditional algorithms.
Abstract: Effective statistical feature extraction and classification are important in image-based automatic inspection and analysis. An automatic wood species recognition system is designed to perform wood inspection at custom checkpoints to avoid mislabeling of timber which will results to loss of income to the timber industry. The system focuses on analyzing the statistical pores properties of the wood images. This paper proposed a fuzzy-based feature extractor which mimics the experts’ knowledge on wood texture to extract the properties of pores distribution from the wood surface texture. The proposed feature extractor consists of two steps namely pores extraction and fuzzy pores management. The total number of statistical features extracted from each wood image is 38 features. Then, a backpropagation neural network is used to classify the wood species based on the statistical features. A comprehensive set of experiments on a database composed of 5200 macroscopic images from 52 tropical wood species was used to evaluate the performance of the proposed feature extractor. The advantage of the proposed feature extraction technique is that it mimics the experts’ interpretation on wood texture which allows human involvement when analyzing the wood texture. Experimental results show the efficiency of the proposed method.
Abstract: Human skin detection recognized as the primary step in most of the applications such as face detection, illicit image filtering, hand recognition and video surveillance. The performance of any skin detection applications greatly relies on the two components: feature extraction and classification method. Skin color is the most vital information used for skin detection purpose. However, color feature alone sometimes could not handle images with having same color distribution with skin color. A color feature of pixel-based does not eliminate the skin-like color due to the intensity of skin and skin-like color fall under the same distribution. Hence, the statistical color analysis will be exploited such mean and standard deviation as an additional feature to increase the reliability of skin detector. In this paper, we studied the effectiveness of statistical color feature for human skin detection. Furthermore, the paper analyzed the integrated color and texture using eight classifiers with three color spaces of RGB, YCbCr, and HSV. The experimental results show that the integrating statistical feature using Random Forest classifier achieved a significant performance with an F1-score 0.969.
Abstract: The present study explains the somatic marker theory of Antonio Damasio, which indicates that when making a decision, the stored or possible future scenarios (future memory) images allow people to feel for a moment what would happen when they make a choice, and how this is emotionally marked. This process can be conscious or unconscious. The development of new Neuromarketing techniques such as functional magnetic resonance imaging (fMRI), carries a greater understanding of how the brain functions and consumer behavior. In the results observed in different studies using fMRI, the evidence suggests that the somatic marker and future memories influence the decision-making process, adding a positive or negative emotional component to the options. This would mean that all decisions would involve a present emotional component, with a rational cost-benefit analysis that can be performed later.
Abstract: In Ultra high-field MRI scanners (3T and higher),
parallel RF transmission techniques using multiple RF chains with
multiple transmit elements are a promising approach to overcome
the high-field MRI challenges in terms of inhomogeneity in the RF
magnetic field and SAR. However, mutual coupling between the
transmit array elements disturbs the desirable independent control of
the RF waveforms for each element. This contribution demonstrates
a 18 dB improvement of decoupling (isolation) performance due to
the very low output impedance of our 1 kW power amplifier.
Abstract: Magnetic Resonance Imaging Contrast Agents
(MRI-CM) are significant in the clinical and biological imaging as
they have the ability to alter the normal tissue contrast, thereby
affecting the signal intensity to enhance the visibility and detectability
of images. Superparamagnetic Iron Oxide (SPIO) nanoparticles,
coated with dextran or carboxydextran are currently available for
clinical MR imaging of the liver. Most SPIO contrast agents are
T2 shortening agents and Resovist (Ferucarbotran) is one of a
clinically tested, organ-specific, SPIO agent which has a low
molecular carboxydextran coating. The enhancement effect of
Resovist depends on its relaxivity which in turn depends on factors
like magnetic field strength, concentrations, nanoparticle properties,
pH and temperature. Therefore, this study was conducted to
investigate the impact of field strength and different contrast
concentrations on enhancement effects of Resovist. The study
explored the MRI signal intensity of Resovist in the physiological
range of plasma from T2-weighted spin echo sequence at three
magnetic field strengths: 0.47 T (r1=15, r2=101), 1.5 T (r1=7.4,
r2=95), and 3 T (r1=3.3, r2=160) and the range of contrast
concentrations by a mathematical simulation. Relaxivities of r1 and r2
(L mmol-1 Sec-1) were obtained from a previous study and the selected
concentrations were 0.05, 0.06, 0.07, 0.08, 0.09, 0.1, 0.2, 0.3, 0.4, 0.5,
0.6, 0.7, 0.8, 0.9, 1.0, 2.0, and 3.0 mmol/L. T2-weighted images were
simulated using TR/TE ratio as 2000 ms /100 ms. According to the
reference literature, with increasing magnetic field strengths, the
r1 relaxivity tends to decrease while the r2 did not show any
systematic relationship with the selected field strengths. In parallel,
this study results revealed that the signal intensity of Resovist at lower
concentrations tends to increase than the higher concentrations. The
highest reported signal intensity was observed in the low field strength
of 0.47 T. The maximum signal intensities for 0.47 T, 1.5 T and 3 T
were found at the concentration levels of 0.05, 0.06 and 0.05 mmol/L,
respectively. Furthermore, it was revealed that, the concentrations
higher than the above, the signal intensity was decreased
exponentially. An inverse relationship can be found between the field
strength and T2 relaxation time, whereas, the field strength was
increased, T2 relaxation time was decreased accordingly. However,
resulted T2 relaxation time was not significantly different between
0.47 T and 1.5 T in this study. Moreover, a linear correlation of
transverse relaxation rates (1/T2, s–1) with the concentrations of
Resovist can be observed. According to these results, it can conclude
that the concentration of SPIO nanoparticle contrast agents and the
field strengths of MRI are two important parameters which can affect the signal intensity of T2-weighted SE sequence. Therefore, when MR
imaging those two parameters should be considered prudently.
Abstract: This study was aimed to measure effective transverse
relaxation rates (R2*) in the liver and muscle of normal New Zealand
White (NZW) rabbits. R2* relaxation rate has been widely used in
various hepatic diseases for iron overload by quantifying iron contents
in liver. R2* relaxation rate is defined as the reciprocal of T2*
relaxation time and mainly depends on the constituents of tissue.
Different tissues would have different R2* relaxation rates. The signal
intensity decay in Magnetic resonance imaging (MRI) may be
characterized by R2* relaxation rates. In this study, a 1.5T GE Signa
HDxt whole body MR scanner equipped with an 8-channel high
resolution knee coil was used to observe R2* values in NZW rabbit’s
liver and muscle. Eight healthy NZW rabbits weighted 2 ~ 2.5 kg were
recruited. After anesthesia using Zoletil 50 and Rompun 2% mixture,
the abdomen of rabbit was landmarked at the center of knee coil to
perform 3-plane localizer scan using fast spoiled gradient echo
(FSPGR) pulse sequence. Afterwards, multi-planar fast gradient echo
(MFGR) scans were performed with 8 various echo times (TEs) to
acquire images for R2* measurements. Regions of interest (ROIs) at
liver and muscle were measured using Advantage workstation.
Finally, the R2* was obtained by a linear regression of ln(sı) on TE.
The results showed that the longer the echo time, the smaller the signal
intensity. The R2* values of liver and muscle were 44.8 ± 10.9 s-1 and
37.4 ± 9.5 s-1, respectively. It implies that the iron concentration of
liver is higher than that of muscle. In conclusion, the more the iron
contents in tissue, the higher the R2*. The correlations between R2*
and iron content in NZW rabbits might be valuable for further
exploration.
Abstract: Magnetic Resonance Imaging (MRI) is one of the
most important medical imaging modality. Subjective assessment of
the image quality is regarded as the gold standard to evaluate MR
images. In this study, a database of 210 MR images which contains
ten reference images and 200 distorted images is presented. The
reference images were distorted with four types of distortions: Rician
Noise, Gaussian White Noise, Gaussian Blur and DCT compression.
The 210 images were assessed by ten subjects. The subjective scores
were presented in Difference Mean Opinion Score (DMOS). The
DMOS values were compared with four FR-IQA metrics. We have
used Pearson Linear Coefficient (PLCC) and Spearman Rank Order
Correlation Coefficient (SROCC) to validate the DMOS values. The
high correlation values of PLCC and SROCC shows that the DMOS
values are close to the objective FR-IQA metrics.
Abstract: Cancer is still one of the serious diseases threatening
the lives of human beings. How to have an early diagnosis and
effective treatment for tumors is a very important issue. The animal
carcinoma model can provide a simulation tool for the studies of
pathogenesis, biological characteristics, and therapeutic effects.
Recently, drug delivery systems have been rapidly developed to
effectively improve the therapeutic effects. Liposome plays an
increasingly important role in clinical diagnosis and therapy for
delivering a pharmaceutic or contrast agent to the targeted sites.
Liposome can be absorbed and excreted by the human body, and is
well known that no harm to the human body. This study aimed to
compare the therapeutic effects between encapsulated (doxorubicin
liposomal, Lipodox) and un-encapsulated (doxorubicin, Dox)
anti-tumor drugs using magnetic resonance imaging (MRI).
Twenty-four New Zealand rabbits implanted with VX2 carcinoma at
left thighs were classified into three groups: control group (untreated),
Dox-treated group, and LipoDox-treated group, 8 rabbits for each
group. MRI scans were performed three days after tumor implantation.
A 1.5T GE Signa HDxt whole body MRI scanner with a high
resolution knee coil was used in this study. After a 3-plane localizer
scan was performed, three-dimensional (3D) fast spin echo (FSE)
T2-weighted Images (T2WI) was used for tumor volumetric
quantification. Afterwards, two-dimensional (2D) spoiled gradient
recalled echo (SPGR) dynamic contrast-enhanced (DCE) MRI was
used for tumor perfusion evaluation. DCE-MRI was designed to
acquire four baseline images, followed by contrast agent Gd-DOTA
injection through the ear vein of rabbit. A series of 32 images were
acquired to observe the signals change over time in the tumor and
muscle. The MRI scanning was scheduled on a weekly basis for a
period of four weeks to observe the tumor progression longitudinally.
The Dox and LipoDox treatments were prescribed 3 times in the first
week immediately after the first MRI scan; i.e. 3 days after VX2 tumor
implantation. ImageJ was used to quantitate tumor volume and time
course signal enhancement on DCE images. The changes of tumor size
showed that the growth of VX2 tumors was effectively inhibited for
both LipoDox-treated and Dox-treated groups. Furthermore, the tumor
volume of LipoDox-treated group was significantly lower than that of
Dox-treated group, which implies that LipoDox has better therapeutic effect than Dox. The signal intensity of LipoDox-treated group is
significantly lower than that of the other two groups, which implies
that targeted therapeutic drug remained in the tumor tissue. This study
provides a radiation-free and non-invasive MRI method for
therapeutic monitoring of targeted liposome on an animal tumor
model.
Abstract: In this paper, we present an application of Riemannian
geometry for processing non-Euclidean image data. We consider the
image as residing in a Riemannian manifold, for developing a new
method to brain edge detection and brain extraction. Automating this
process is a challenge due to the high diversity in appearance brain
tissue, among different patients and sequences. The main contribution, in this paper, is the use of an edge-based
anisotropic diffusion tensor for the segmentation task by integrating
both image edge geometry and Riemannian manifold (geodesic,
metric tensor) to regularize the convergence contour and extract
complex anatomical structures. We check the accuracy of the
segmentation results on simulated brain MRI scans of single
T1-weighted, T2-weighted and Proton Density sequences. We
validate our approach using two different databases: BrainWeb
database, and MRI Multiple sclerosis Database (MRI MS DB). We
have compared, qualitatively and quantitatively, our approach with
the well-known brain extraction algorithms. We show that using
a Riemannian manifolds to medical image analysis improves the
efficient results to brain extraction, in real time, outperforming the
results of the standard techniques.
Abstract: CuO thin films were deposited by spray ultrasonic
pyrolysis with different precursor solution. Two staring solution slats
were used namely: copper acetate and copper chloride. The influence
of these solutions on CuO thin films proprieties of is instigated. The
X rays diffraction (XDR) analysis indicated that the films deposed
with copper acetate are amorphous however the films elaborated with
copper chloride have monoclinic structure. UV- Visible transmission
spectra showed a strong absorbance of the deposited CuO thin films
in the visible region. Electrical characterization has shown that CuO
thin films prepared with copper acetate have a higher electrical
conductivity.
Abstract: Nowadays, illegal logging has been causing many
effects including flash flood, avalanche, global warming, and etc. The
purpose of this study was to maintain the earth ecosystem by keeping
and regulate Malaysia’s treasurable rainforest by utilizing a new
technology that will assist in real-time alert and give faster response
to the authority to act on these illegal activities. The methodology of
this research consisted of design stages that have been conducted as
well as the system model and system architecture of the prototype in
addition to the proposed hardware and software that have been
mainly used such as microcontroller, sensor with the implementation
of GSM, and GPS integrated system. This prototype was deployed at
Royal Belum forest in December 2014 for phase 1 and April 2015 for
phase 2 at 21 pinpoint locations. The findings of this research were
the capture of data in real-time such as temperature, humidity,
gaseous, fire, and rain detection which indicate the current natural
state and habitat in the forest. Besides, this device location can be
detected via GPS of its current location and then transmitted by SMS
via GSM system. All of its readings were sent in real-time for further
analysis. The data that were compared to meteorological department
showed that the precision of this device was about 95% and these
findings proved that the system is acceptable and suitable to be used
in the field.
Abstract: In this numerical work, mixed convection and entropy
generation of Cu–water nanofluid in a lid-driven square cavity have
been investigated numerically using the Lattice Boltzmann Method.
Horizontal walls of the cavity are adiabatic and vertical walls have
constant temperature but different values. The top wall has been
considered as moving from left to right at a constant speed, U0. The
effects of different parameters such as nanoparticle volume
concentration (0–0.05), Rayleigh number (104–106) and Reynolds
numbers (1, 10 and 100) on the entropy generation, flow and
temperature fields are studied. The results have shown that addition
of nanoparticles to the base fluid affects the entropy generation, flow
pattern and thermal behavior especially at higher Rayleigh and low
Reynolds numbers. For pure fluid as well as nanofluid, the increase
of Reynolds number increases the average Nusselt number and the
total entropy generation, linearly. The maximum entropy generation
occurs in nanofluid at low Rayleigh number and at high Reynolds
number. The minimum entropy generation occurs in pure fluid at low
Rayleigh and Reynolds numbers. Also at higher Reynolds number,
the effect of Cu nanoparticles on enhancement of heat transfer was
decreased because the effect of lid-driven cavity was increased. The
present results are validated by favorable comparisons with
previously published results. The results of the problem are presented
in graphical and tabular forms and discussed.
Abstract: In this paper, we present a new segmentation approach
for liver lesions in regions of interest within MRI (Magnetic
Resonance Imaging). This approach, based on a two-cluster Fuzzy CMeans
methodology, considers the parameter variable compactness
to handle uncertainty. Fine boundaries are detected by a local
recursive merging of ambiguous pixels with a sequential forward
floating selection with Zernike moments. The method has been tested
on both synthetic and real images. When applied on synthetic images,
the proposed approach provides good performance, segmentations
obtained are accurate, their shape is consistent with the ground truth,
and the extracted information is reliable. The results obtained on MR
images confirm such observations. Our approach allows, even for
difficult cases of MR images, to extract a segmentation with good
performance in terms of accuracy and shape, which implies that the
geometry of the tumor is preserved for further clinical activities (such
as automatic extraction of pharmaco-kinetics properties, lesion
characterization, etc.).
Abstract: Neural activity in the human brain starts from the
early stages of prenatal development. This activity or signals
generated by the brain are electrical in nature and represent not only
the brain function but also the status of the whole body. At the
present moment, three methods can record functional and
physiological changes within the brain with high temporal resolution
of neuronal interactions at the network level: the
electroencephalogram (EEG), the magnet oencephalogram (MEG),
and functional magnetic resonance imaging (fMRI); each of these has
advantages and shortcomings. EEG recording with a large number of
electrodes is now feasible in clinical practice. Multichannel EEG
recorded from the scalp surface provides very valuable but indirect
information about the source distribution. However, deep electrode
measurements yield more reliable information about the source
locations intracranial recordings and scalp EEG are used with the
source imaging techniques to determine the locations and strengths of
the epileptic activity. As a source localization method, Low
Resolution Electro-Magnetic Tomography (LORETA) is solved for
the realistic geometry based on both forward methods, the Boundary
Element Method (BEM) and the Finite Difference Method (FDM). In
this paper, we review the findings EEG- LORETA about epilepsy.
Abstract: When neck pain is associated with pain, numbness, or
weakness in the arm, shoulder, or hand, further investigation is
needed as these are symptoms indicating pressure on one or more
nerve roots. Evaluation necessitates a neurologic examination and
imaging using an MRI/CT scan. A degenerating disc loses some
thickness and is less flexible, causing inter-vertebrae space to narrow.
A radiologist diagnoses an Intervertebral Disc Degeneration (IDD) by
localizing every inter-vertebral disc and identifying the pathology in
a disc based on its geometry and appearance. Accurate localizing is
necessary to diagnose IDD pathology. But, the underlying image
signal is ambiguous: a disc’s intensity overlaps the spinal nerve
fibres. Even the structure changes from case to case, with possible
spinal column bending (scoliosis). The inter-vertebral disc
pathology’s quantitative assessment needs accurate localization of the
cervical region discs. In this work, the efficacy of multilevel set
segmentation model, to segment cervical discs is investigated. The
segmented images are annotated using a simple distance matrix.