Abstract: Improving the energy performance of existing buildings can be challenging, particularly when facades cannot be modified, and the only available option is internal insulation. In such cases, the choice of the most suitable material becomes increasingly complex, as in addition to thermal transmittance and capital cost, the designer needs to account for the impact of the intervention on the internal spaces, and in particular the loss of usable space due to the additional layers of materials installed. This paper explores this issue by analyzing a case study of an average office building needing to go through a refurbishment in order to reach the limits imposed by current regulations to achieve energy efficiency in buildings. The building is simulated through dynamic performance simulation under three different climate conditions in order to evaluate its energy needs. The use of Vacuum Insulated Panels as an option for energy refurbishment is compared to traditional insulation materials (XPS, Mineral Wool). For each scenario, energy consumptions are calculated and, in combination with their expected capital costs, used to perform a financial feasibility analysis. A holistic approach is proposed, taking into account the impact of the intervention on internal space by quantifying the value of the lost usable space and used in the financial feasibility analysis. The proposed approach highlights how taking into account different drivers will lead to the choice of different insulation materials, showing how accounting for the economic value of space can make VIPs an attractive solution for energy retrofitting under various climate conditions.
Abstract: In the fight against climate change, the energy consuming building sector must also be taken into account to solve this problem. In this case thermal insulation of buildings using bio-based materials is an interesting solution. Therefore, the thermal performance of some materials of this type has been studied. The advantages of these natural materials of plant origin are multiple, biodegradable, low economic cost, renewable and readily available. The use of biobased materials is widespread in the building sector in order to replace conventional insulation materials with natural materials. Vegetable fibers are very important because they have good thermal behaviour and good insulating properties. The aim of using bio-sourced materials is in line with the logic of energy control and environmental protection, the approach is to make the inhabitants of the houses comfortable and reduce their energy consumption (energy efficiency). In this research we will present the results of studies carried out on the thermal conductivity of banana leaves, latan leaves, vetivers fibers, palm kernel fibers, sargassum, coconut leaves, sawdust and bulk sugarcane leaves. The study on thermal conductivity was carried out in two ways, on the one hand using the flash method, and on the other hand a so-called hot box experiment was carried out. We will discuss and highlight a number of influential factors such as moisture and air pockets present in the samples on the thermophysical properties of these materials, in particular thermal conductivity. Finally, the result of a thermal performance test of banana leaves on a roof in Haiti will also be presented in this work.
Abstract: Insulators are one of the most significant equipment in power system. The insulators’ operation may affect the power flow, line loss and reliability. The electrical parameters that influence the performance of insulator are surface leakage current, corona and dry band arcing. Electric field stresses on the insulator surface will degrade the insulating properties and lead to puncture. Electric filed stresses can be analyzed by numerical methods and experimental evaluation. As per economic aspects, evaluation by numerical methods are best. In outdoor insulation, a hydrophobic surface can facilitate to prevent water film formation on the insulation surface, which is decisive for diminishing leakage currents and partial discharge (PD) under heavy polluted environments and harsh weather conditions. Polymer materials like silicone rubber have an outstanding hydrophobic property among general insulation materials. In this paper, electrical field intensity of 220 kV porcelain and polymer double tension insulator strings at critical regions are analyzed and compared by using Finite Element Method. Hydrophobic conditions of polymer insulator with equal and unequal water molecule conditions are verified by using finite element method.
Abstract: The thermal conductivity of thermal insulation materials are measured by Heat Flow Meter (HFM) apparatus. The components of uncertainty are complex and difficult on routine measurement by modelling approach. In this study, uncertainty of thermal conductivity measurement was estimated by single laboratory validation approach. The within-laboratory reproducibility was 1.1%. The standard uncertainty of method and laboratory bias by using SRM1453 expanded polystyrene board was dominant at 1.4%. However, it was assessed that there was no significant bias. For sample measurement, the sources of uncertainty were repeatability, density of sample and thermal conductivity resolution of HFM. From this approach to sample measurements, the combined uncertainty was calculated. In summary, the thermal conductivity of sample, polystyrene foam, was reported as 0.03367 W/m·K ± 3.5% (k = 2) at mean temperature 23.5 °C. The single laboratory validation approach is simple key of routine testing laboratory for estimation uncertainty of thermal conductivity measurement by using HFM, according to ISO/IEC 17025-2017 requirements. These are meaningful for laboratory competent improvement, quality control on products, and conformity assessment.
Abstract: There is a great problem in testing and investigations the reliability of different type of transformers insulation materials. It summarized in how to create and simulate the real conditions of working transformer and testing its insulation materials for Partial Discharge PD, typically as in the working mode. A lot of tests may give untrue results as the physical behavior of the insulation material differs under tests from its working condition. In this work, the real working conditions were simulated, and a large number of specimens have been tested. The investigations first stage, begin with choosing samples of different types of insulation materials (papers, pressboards, etc.). The second stage, the samples were dried in ovens at 105 C0and 0.01bar for 48 hours, and then impregnated with dried and gasless oil (the water content less than 6 ppm.) at 105 C0and 0.01bar for 48 hours, after so specimen cooling at room pressure and temperature for 24 hours. The third stage is investigating PD for the samples using ICM PD measuring device. After that, a continuous test on oil-impregnated insulation materials (paper, pressboards) was developed, and the phase resolved partial discharge pattern of PD signals was measured. The important of this work in providing the industrial sector with trusted high accurate measuring results based on real simulated working conditions. All the PD patterns (results) associated with a discharge produced in well-controlled laboratory condition. They compared with other previous and other laboratory results. In addition, the influence of different temperatures condition on the partial discharge activities was studied.
Abstract: Accurate prediction of the cooling/heating load and consequently, the sizing of the heating, ventilating, and air-conditioning equipment require precise calculation of the heat transfer mainly by conduction through envelope components of a building. The thermal resistance of most thermal insulation materials depends on the operating temperature. The temperature to which the insulation materials are exposed varies, depending on the thermal resistance of the materials, the location of the insulation layer within the assembly system, and the effective temperature which depends on the amount of solar radiation received on the surface of the assembly. The main objective of this paper is to investigate the change of the thermal conductivity of polystyrene insulation material in terms of the temperature at the mid-thickness of the material and its effect on the cooling load required by the building.
Abstract: The performance of box-type solar cookers has been
reported by several researchers but little attention was paid to the
effect of the type of insulation material on the energy and exergy
efficiency of these cookers. This research aimed at evaluating the
energy and exergy efficiencies of the box-type cookers containing
different insulation materials. Energy and exergy efficiencies of five
box-type solar cookers insulated with maize cob, air (control), maize
husk, coconut coir and polyurethane foam respectively were obtained
over a period of three years. The cookers were evaluated using water
heating test procedures in determining the energy and exergy
analysis. The results were subjected to statistical analysis using
ANOVA. The result shows that the average energy input for the five
solar cookers were: 245.5, 252.2, 248.7, 241.5 and 245.5J
respectively while their respective average energy losses were: 201.2,
212.7, 208.4, 189.1 and 199.8J. The average exergy input for five
cookers were: 228.2, 234.4, 231.1, 224.4 and 228.2J respectively
while their respective average exergy losses were: 223.4, 230.6,
226.9, 218.9 and 223.0J. The energy and exergy efficiency was
highest in the cooker with coconut coir (37.35 and 3.90%
respectively) in the first year but was lowest for air (11 and 1.07%
respectively) in the third year. Statistical analysis showed significant
difference between the energy and exergy efficiencies over the years.
These results reiterate the importance of a good insulating material
for a box-type solar cooker.
Abstract: The majority of contemporary insulation materials
commonly used in the building industry is made from non-renewable
raw materials; furthermore, their production often brings high energy
costs. A long-term trend as far as sustainable development is
concerned has been the reduction of energy and material demands of
building material production. One of the solutions is the possibility of
using easily renewable natural raw material sources which are
considerably more ecological and their production is mostly less
energy-consuming compared to the production of normal insulations
(mineral wool, polystyrene). The paper describes the results of
research focused on the development of thermal and acoustic
insulation materials based on natural fibres intended for floor
constructions. Given the characteristic open porosity of natural fibre
materials, the hygrothermal behaviour of the developed materials was
studied. Especially the influence of relative humidity and temperature
on thermal insulation properties was observed.
Abstract: Thermal insulation materials based on natural fibers
represent a very promising area of materials based on natural easy
renewable row sources. These materials may be in terms of the
properties of most competing synthetic insulations, but show
somewhat higher moisture sensitivity and thermal insulation
properties are strongly influenced by the density and orientation of
fibers. The paper described the problem of hygrothermal behavior of
thermal insulation materials based on natural plant and animal fibers.
This is especially the dependence of the thermal properties of these
materials on the type of fiber, bulk density, temperature, moisture and
the fiber orientation.
Abstract: When insulation and rehabilitation of structures is important to use quality building materials with high utility value. One potentially interesting and promising groups of construction materials in this area are advanced, thermally insulating plaster silicate based. With the present trend reduction of energy consumption of building structures and reducing CO2 emissions to be developed capillary-active materials that are characterized by their low density, low thermal conductivity while maintaining good mechanical properties.
The paper describes the results of research activities aimed at the development of thermal insulating and rehabilitation material ongoing at the Technical University in Brno, Faculty of Civil Engineering. The achieved results of this development will be the basis for subsequent experimental analysis of the influence of thermal and moisture loads developed on these materials.
Abstract: The 'wind-rain' house has a courtyard with glazed
roof, which allows more direct sunlight to come into indoor spaces
during the winter. The glazed roof can be partially opened or closed
and automatically controlled to provide natural ventilation in order to
adjust for indoor thermal conditions and the roof area can be shaded
by reflective insulation materials during the summer. Two field
studies for evaluating indoor thermal conditions of the two 'windrain'
houses have been carried out by author in 2009 and 2010.
Indoor and outdoor air temperature and relative humidity adjacent to
floor and ceiling of the two sample houses were continuously tested
at 15-minute intervals, 24 hours a day during the winter months.
Based on field study data, this study investigates relationships
between building design and indoor thermal condition of the 'windrain'
house to improve the future house design for building thermal
comfort and energy efficiency
Abstract: The heat storage capacity of concrete in building shells is a major reason for excessively large electricity consumption induced by indoor air conditioning. In this research, the previously developed Smart Temperature Information Material (STIM) is embedded in two groups of exterior wall specimens (the control group contains reinforced concrete exterior walls and the experimental group consists of tiled exterior walls). Long term temperature measurements within the concrete are taken by the embedded STIM. Temperature differences between the control group and the experimental group in walls facing the four cardinal directions (east, west, south, and north) are evaluated. This study aims to provide a basic reference for the design of exterior walls and the selection of heat insulation materials.
Abstract: Axial Flux Permanent Magnet (AFPM) Machines require effective cooling due to their high power density. The detrimental effects of overheating such as degradation of the insulation materials, magnets demagnetization, and increase of Joule losses are well known. This paper describes the CFD simulations performed on a test rig model of an air cooled Axial Flux Permanent Magnet (AFPM) generator built at Durham University to identify the temperatures and heat transfer coefficient on the stator. The Reynolds Averaged Navier-Stokes and the Energy equations are solved and the flow pattern and heat transfer developing inside the machine are described. The Nusselt number on the stator surfaces has been found. The dependency of the heat transfer on the flow field is described temperature field obtained. Tests on an experimental are undergoing in order to validate the CFD results.
Abstract: The major objective of this study is to understand the
potential of a newly fabricated equipment to study the thermal
properties of nonwoven textile fabrics treated with aerogel at subzero
temperatures. Thermal conductivity was calculated by using the
empirical relation Fourier’s law, The relationship between the
thermal conductivity and thermal resistance of the samples were
studied at various environmental temperatures (which was set in the
clima temperature system between +25oC to -25oC). The newly
fabricated equipment was found to be a suitable for measuring at
subzero temperatures. This field of measurements is being developed
and will be the subject of further research which will be more suitable
for measurement of the various thermal characteristics.
Abstract: A macroscopic constitutive equation is developed for a high-density cellulose insulation material with emphasis on the outof- plane stress relaxation behavior. A hypothesis is proposed where the total stress is additively composed by an out-of-plane visco-elastic isotropic contribution and an in-plane elastic orthotropic response. The theory is validated against out-of-plane stress relaxation, compressive experiments and in-plane tensile hysteresis, respectively. For large scale finite element simulations, the presented model provides a balance between simplicity and capturing the materials constitutive behaviour.