Abstract: The present paper discusses the prediction of gas-liquid two-phase frictional pressure drop in a 2.12 mm horizontal circular minichannel using Artificial Neural Network (ANN). The experimental results are obtained with air as gas phase and water as liquid phase. The superficial gas velocity is kept in the range of 0.0236 m/s to 0.4722 m/s while the values of 0.0944 m/s, 0.1416 m/s and 0.1889 m/s are considered for superficial liquid velocity. The experimental results are predicted using different Artificial Neural Network (ANN) models. Networks used for prediction are radial basis, generalised regression, linear layer, cascade forward back propagation, feed forward back propagation, feed forward distributed time delay, layer recurrent, and Elman back propagation. Transfer functions used for networks are Linear (PURELIN), Logistic sigmoid (LOGSIG), tangent sigmoid (TANSIG) and Gaussian RBF. Combination of networks and transfer functions give different possible neural network models. These models are compared for Mean Absolute Relative Deviation (MARD) and Mean Relative Deviation (MRD) to identify the best predictive model of ANN.
Abstract: Two-phase frictional pressure drop data were
obtained for condensation of carbon dioxide in single horizontal
micro tube of inner diameter ranged from 0.6 mm up to 1.6 mm over
mass flow rates from 2.5*10-5 to 17*10-5 kg/s and vapor qualities
from 0.0 to 1.0. The inlet condensing pressure is changed from 33.5
to 45 bars. The saturation temperature ranged from -1.5 oC up to 10
oC. These data have then been compared against three (two-phase)
frictional pressure drop prediction methods. The first method is by
Muller-Steinhagen and Heck (Muller-Steinhagen H, Heck K. A
simple friction pressure drop correlation for two-phase flow in pipes.
Chem. Eng. Process 1986;20:297–308) and that by Gronnerud R.
Investigation of liquid hold-up, flow-resistance and heat transfer in
circulation type evaporators, part IV: two-phase flow resistance in
boiling refrigerants, Annexe 1972. Then the method used by
FriedelL. Improved friction pressures drop in horizontal and vertical
two-phase pipe flow. European Two-Phase Flow Group Meeting,
Paper E2; 1979 June, Ispra, Italy. The methods are used by M.B Ould
Didi et al (2001) “Prediction of two-phase pressure gradients of
refrigerant in horizontal tubes". Int.J.of Refrigeration 25(2002) 935-
947. The best available method for annular flow was that of Muller-
Steinhagen and Heck. It was observed that the peak in the two-phase
frictional pressure gradient is at high vapor qualities.
Abstract: In designing of condensers, the prediction of pressure
drop is as important as the prediction of heat transfer coefficient.
Modeling of two phase flow, particularly liquid – vapor flow under
diabatic conditions inside a horizontal tube using CFD analysis is
difficult with the available two phase models in FLUENT due to
continuously changing flow patterns. In the present analysis, CFD
analysis of two phase flow of refrigerants inside a horizontal tube of
inner diameter, 0.0085 m and 1.2 m length is carried out using
homogeneous model under adiabatic conditions. The refrigerants
considered are R22, R134a and R407C. The analysis is performed at
different saturation temperatures and at different flow rates to
evaluate the local frictional pressure drop. Using Homogeneous
model, average properties are obtained for each of the refrigerants
that is considered as single phase pseudo fluid. The so obtained
pressure drop data is compared with the separated flow models
available in literature.