Abstract: The existing two-dimensional micro-Doppler features extraction ignores the correlation information between the spatial and temporal dimension features. For the range-Doppler map, the time dimension is introduced, and a frequency modulation continuous wave (FMCW) radar human fall detection algorithm based on time-varying range-Doppler features is proposed. Firstly, the range-Doppler sequence maps are generated from the echo signals of the continuous motion of the human body collected by the radar. Then the three-dimensional data cube composed of multiple frames of range-Doppler maps is input into the three-dimensional Convolutional Neural Network (3D CNN). The spatial and temporal features of time-varying range-Doppler are extracted by the convolution layer and pool layer at the same time. Finally, the extracted spatial and temporal features are input into the fully connected layer for classification. The experimental results show that the proposed fall detection algorithm has a detection accuracy of 95.66%.
Abstract: In this paper, an embedded frequency modulation
(FM) transmission control software (SW) for a low power battery
system is designed and implemented. The simultaneous translation
systems for various languages are needed as so many international
conferences and festivals are held in world wide. Especially in
portable transmitting and receiving systems, the ability of long
operation life is used for a measure of value. This paper proposes
an embedded FM transmission control SW for low power battery
system and shows the results of the SW implemented on a portable
FM transmission system.
Abstract: These days, the industrial trend is moving away from heavy and bulky passive components to power converter systems that use more and more semiconductor elements. Also, it is difficult to connect the traditional converters to the high and medium voltage. For these reasons, a new family of multilevel inverters has appeared as a solution for working with higher voltage levels. Different modulation topologies like Sinusoidal Pulse Width Modulation (SPWM), Selective Harmonic Elimination Pulse Width Modulation (SHE-PWM) are available for multilevel inverters. In this work, different hybrid modulation techniques which are combination of fundamental frequency modulation and multilevel sinusoidal-modulation are compared. The main characteristic of these modulations are reduction of switching losses with good harmonic performance and balanced power loss dissipation among the device. The proposed hybrid modulation schemes are developed and simulated in Matlab/Simulink for cascaded H-bridge inverter. The results validate the applicability of the proposed schemes for cascaded multilevel inverter.
Abstract: Radio propagation from point-to-point is affected by
the physical channel in many ways. A signal arriving at a destination
travels through a number of different paths which are referred to as
multi-paths. Research in this area of wireless communications has
progressed well over the years with the research taking different
angles of focus. By this is meant that some researchers focus on
ways of reducing or eluding Multipath effects whilst others focus on
ways of mitigating the effects of Multipath through compensation
schemes. Baseband processing is seen as one field of signal
processing that is cardinal to the advancement of software defined
radio technology. This has led to wide research into the carrying out
certain algorithms at baseband. This paper considers compensating
for Multipath for Frequency Modulated signals. The compensation
process is carried out at Radio frequency (RF) and at Quadrature
baseband (QBB) and the results are compared. Simulations are
carried out using MatLab so as to show the benefits of working at
lower QBB frequencies than at RF.
Abstract: The experimental and theoretical results of a ZVS
(Zero Voltage Switching) isolated flyback DC-DC converter using
multilayered coreless PCB step down 2:1 transformer are presented.
The performance characteristics of the transformer are shown which
are useful for the parameters extraction. The measured energy
efficiency of the transformer is found to be more than 94% with the
sinusoidal input voltage excitation. The designed flyback converter
has been tested successfully upto the output power level of 10W,
with a switching frequency in the range of 2.7MHz-4.3MHz. The
input voltage of the converter is varied from 25V-40V DC.
Frequency modulation technique is employed by maintaining
constant off time to regulate the output voltage of the converter. The
energy efficiency of the isolated flyback converter circuit under ZVS
condition in the MHz frequency region is found to be approximately
in the range of 72-84%. This paper gives the comparative results in
terms of the energy efficiency of the hard switched and soft switched
flyback converter in the MHz frequency region.
Abstract: This research paper presents some methods to assess the performance of Wigner Ville Distribution for Time-Frequency representation of non-stationary signals, in comparison with the other representations like STFT, Spectrogram etc. The simultaneous timefrequency resolution of WVD is one of the important properties which makes it preferable for analysis and detection of linear FM and transient signals. There are two algorithms proposed here to assess the resolution and to compare the performance of signal detection. First method is based on the measurement of area under timefrequency plot; in case of a linear FM signal analysis. A second method is based on the instantaneous power calculation and is used in case of transient, non-stationary signals. The implementation is explained briefly for both methods with suitable diagrams. The accuracy of the measurements is validated to show the better performance of WVD representation in comparison with STFT and Spectrograms.
Abstract: Electromagnetic interference (EMI) is one of the
serious problems in most electrical and electronic appliances
including fluorescent lamps. The electronic ballast used to regulate
the power flow through the lamp is the major cause for EMI. The
interference is because of the high frequency switching operation of
the ballast. Formerly, some EMI mitigation techniques were in
practice, but they were not satisfactory because of the hardware
complexity in the circuit design, increased parasitic components and
power consumption and so on. The majority of the researchers have
their spotlight only on EMI mitigation without considering the other
constraints such as cost, effective operation of the equipment etc. In
this paper, we propose a technique for EMI mitigation in fluorescent
lamps by integrating Frequency Modulation and Evolutionary
Programming. By the Frequency Modulation technique, the
switching at a single central frequency is extended to a range of
frequencies, and so, the power is distributed throughout the range of
frequencies leading to EMI mitigation. But in order to meet the
operating frequency of the ballast and the operating power of the
fluorescent lamps, an optimal modulation index is necessary for
Frequency Modulation. The optimal modulation index is determined
using Evolutionary Programming. Thereby, the proposed technique
mitigates the EMI to a satisfactory level without disturbing the
operation of the fluorescent lamp.