Abstract: Bleeding in the digestive duct is an important diagnostic parameter for patients. Blood in the endoscopic image can be determined by investigating the color tone of blood due to the degree of oxygenation, under- or over- illumination, food debris and secretions, etc. However, we found that how to pre-process raw images obtained from the capsule detectors was very important. We applied various image process methods suitable for the capsule endoscopic image in order to remove noises and unbalanced sensitivities for the image pixels. The results showed that much improvement was achieved by additional pre-processing techniques on the algorithm of determining bleeding areas.
Abstract: Martingale model diagnostic for assessing the fit of logistic regression model to recurrent events data are studied. One way of assessing the fit is by plotting the empirical standard deviation of the standardized martingale residual processes. Here we used another diagnostic plot based on martingale residual covariance. We investigated the plot performance under several types of model misspecification. Clearly the method has correctly picked up the wrong model. Also we present a test statistic that supplement the inspection of the two diagnostic. The test statistic power agrees with what we have seen in the plots of the estimated martingale covariance.
Abstract: The medical studies often require different methods
for parameters selection, as a second step of processing, after the
database-s designing and filling with information. One common
task is the selection of fields that act as risk factors using wellknown
methods, in order to find the most relevant risk factors and
to establish a possible hierarchy between them. Different methods
are available in this purpose, one of the most known being the
binary logistic regression. We will present the mathematical
principles of this method and a practical example of using it in the
analysis of the influence of 10 different psychiatric diagnostics
over 4 different types of offences (in a database made from 289
psychiatric patients involved in different types of offences).
Finally, we will make some observations about the relation
between the risk factors hierarchy established through binary
logistic regression and the individual risks, as well as the results of
Chi-squared test. We will show that the hierarchy built using the
binary logistic regression doesn-t agree with the direct order of risk
factors, even if it was naturally to assume this hypothesis as being
always true.
Abstract: Semiconductor detector arrays are widely used in
high-temperature plasma diagnostics. They have a fast response,
which allows observation of many processes and instabilities in
tokamaks. In this paper, there are reviewed several diagnostics based
on semiconductor arrays as cameras, AXUV photodiodes (referred
often as fast “bolometers") and detectors of both soft X-rays and
visible light installed on the COMPASS tokamak recently. Fresh
results from both spring and summer campaigns in 2012 are
introduced. Examples of the utilization of the detectors are shown on
the plasma shape determination, fast calculation of the radiation
center, two-dimensional plasma radiation tomography in different
spectral ranges, observation of impurity inflow, and also on
investigation of MHD activity in the COMPASS tokamak discharges.
Abstract: A new concept for long-term reagent storage for Labon- a-Chip (LoC) devices is described. Here we present a polymer multilayer stack with integrated stick packs for long-term storage of several liquid reagents, which are necessary for many diagnostic applications. Stick packs are widely used in packaging industry for storing solids and liquids for long time. The storage concept fulfills two main requirements: First, a long-term storage of reagents in stick packs without significant losses and interaction with surroundings, second, on demand releasing of liquids, which is realized by pushing a membrane against the stick pack through pneumatic pressure. This concept enables long-term on-chip storage of liquid reagents at room temperature and allows an easy implementation in different LoC devices.
Abstract: Rapid progress in process automation and tightening
quality standards result in a growing demand being placed on fault
detection and diagnostics methods to provide both speed and
reliability of motor quality testing. Doubly fed induction generators
are used mainly for wind energy conversion in MW power plants.
This paper presents a detection of an inter turn stator and an open
phase faults, in a doubly fed induction machine whose stator and
rotor are supplied by two pulse width modulation (PWM) inverters.
The method used in this article to detect these faults, is based on
Park-s Vector Approach, using a neural network.
Abstract: Echocardiography imaging is one of the most common diagnostic tests that are widely used for assessing the abnormalities of the regional heart ventricle function. The main goal of the image enhancement task in 2D-echocardiography (2DE) is to solve two major anatomical structure problems; speckle noise and low quality. Therefore, speckle noise reduction is one of the important steps that used as a pre-processing to reduce the distortion effects in 2DE image segmentation. In this paper, we present the common filters that based on some form of low-pass spatial smoothing filters such as Mean, Gaussian, and Median. The Laplacian filter was used as a high-pass sharpening filter. A comparative analysis was presented to test the effectiveness of these filters after being applied to original 2DE images of 4-chamber and 2-chamber views. Three statistical quantity measures: root mean square error (RMSE), peak signal-to-ratio (PSNR) and signal-tonoise ratio (SNR) are used to evaluate the filter performance quantitatively on the output enhanced image.
Abstract: Thyroid cancer-s overall contribution to the
worldwide cancer burden is relatively small, but incidence rates have increased over the last three decades throughout the world. This trend has been hypothesised to reflect a combination of technological advances enabling increased detection, but also changes in
environmental factors, including population exposure to ionising radiation from fallout, diagnostic tests and treatment for benign and
malignant conditions. The Thyroid dose received apparently shielded
by cerrobend blocks was about 8cGy in 100cGy Expose
Abstract: TELMES project aims to develop a securized
multimedia system devoted to medical consultation teleservices. It
will be finalized with a pilot system for a regional telecenters
network that connects local telecenters, having as support
multimedia platforms. This network will enable the implementation
of complex medical teleservices (teleconsulations, telemonitoring,
homecare, urgency medicine, etc.) for a broader range of patients
and medical professionals, mainly for family doctors and those
people living in rural or isolated regions. Thus, a multimedia,
scalable network, based on modern IT&C paradigms, will result. It
will gather two inter-connected regional telecenters, in Iaşi and
Piteşti, Romania, each of them also permitting local connections of
hospitals, diagnostic and treatment centers, as well as local networks
of family doctors, patients, even educational entities. As
communications infrastructure, we aim to develop a combined fixmobile-
internet (broadband) links. Other possible communication
environments will be GSM/GPRS/3G and radio waves. The
electrocardiogram (ECG) acquisition, internet transmission and
local analysis, using embedded technologies, was already
successfully done for patients- telemonitoring.
Abstract: Wavelet transform has been extensively used in
machine fault diagnosis and prognosis owing to its strength to deal
with non-stationary signals. The existing Wavelet transform based
schemes for fault diagnosis employ wavelet decomposition of the
entire vibration frequency which not only involve huge
computational overhead in extracting the features but also increases
the dimensionality of the feature vector. This increase in the
dimensionality has the tendency to 'over-fit' the training data and
could mislead the fault diagnostic model. In this paper a novel
technique, envelope wavelet packet transform (EWPT) is proposed in
which features are extracted based on wavelet packet transform of the
filtered envelope signal rather than the overall vibration signal. It not
only reduces the computational overhead in terms of reduced number
of wavelet decomposition levels and features but also improves the
fault detection accuracy. Analytical expressions are provided for the
optimal frequency resolution and decomposition level selection in
EWPT. Experimental results with both actual and simulated machine
fault data demonstrate significant gain in fault detection ability by
EWPT at reduced complexity compared to existing techniques.
Abstract: Current spectrums of a high power induction machine was calculated for the cases of full symmetry, static and dynamic eccentricity. The calculations involve integration of 93 electrical plus four mechanical ordinary differential equations. Electrical equations account for variable inductances affected by slotting and eccentricities. The calculations were followed by Fourier analysis of the stator currents in steady state operation. The paper presents the stator current spectrums in full symmetry, static and dynamic eccentricity cases, and demonstrates the harmonics present in each case. The effect of dynamic eccentricity is demonstrating via comparing the current spectrums related to dynamic eccentricity cases with the full symmetry one. The paper includes one case study, refers to dynamic eccentricity, to present the spectrum of the measured current and demonstrate the existence of the harmonics related to dynamic eccentricity. The zooms of current spectrums around the main slot harmonic zone are included to simplify the comparison and prove the existence of the dynamic eccentricity harmonics in both calculated and measured current spectrums.
Abstract: This paper presents a low cost design of heart beat monitoring device using reflectance mode PhotoPlethysmography (PPG). PPG is known for its simple construction, ease of use and cost effectiveness and can provide information about the changes in cardiac activity as well as aid in earlier non-invasive diagnostics. The proposed device is divided into three phases. First is the detection of pulses through the fingertip. The signal is then passed to the signal processing unit for the purpose of amplification, filtering and digitizing. Finally the heart rate is calculated and displayed on the computer using parallel port interface. The paper is concluded with prototyping of the device followed by verification procedure of the heartbeat signal obtained in laboratory setting.
Abstract: The structure of retinal vessels is a prominent feature,
that reveals information on the state of disease that are reflected in
the form of measurable abnormalities in thickness and colour.
Vascular structures of retina, for implementation of clinical diabetic
retinopathy decision making system is presented in this paper.
Retinal Vascular structure is with thin blood vessel, whose accuracy
is highly dependent upon the vessel segmentation. In this paper the
blood vessel thickness is automatically detected using preprocessing
techniques and vessel segmentation algorithm. First the capture
image is binarized to get the blood vessel structure clearly, then it is
skeletonised to get the overall structure of all the terminal and
branching nodes of the blood vessels. By identifying the terminal
node and the branching points automatically, the main and branching
blood vessel thickness is estimated. Results are presented and
compared with those provided by clinical classification on 50 vessels
collected from Bejan Singh Eye hospital..
Abstract: The Siemens Healthcare Sector is one of the world's
largest suppliers to the healthcare industry and a trendsetter in
medical imaging and therapy, laboratory diagnostics, medical
information technology, and hearing aids.
Siemens offers its customers products and solutions for the entire
range of patient care from a single source – from prevention and
early detection to diagnosis, and on to treatment and aftercare. By
optimizing clinical workflows for the most common diseases,
Siemens also makes healthcare faster, better, and more cost effective.
The optimization of clinical workflows requires a
multidisciplinary focus and a collaborative approach of e.g. medical
advisors, researchers and scientists as well as healthcare economists.
This new form of collaboration brings together experts with deep
technical experience, physicians with specialized medical knowledge
as well as people with comprehensive knowledge about health
economics.
As Charles Darwin is often quoted as saying, “It is neither the
strongest of the species that survive, nor the most intelligent, but the
one most responsive to change," We believe that those who can
successfully manage this change will emerge as winners, with
valuable competitive advantage.
Current medical information and knowledge are some of the core
assets in the healthcare industry. The main issue is to connect
knowledge holders and knowledge recipients from various
disciplines efficiently in order to spread and distribute knowledge.
Abstract: Today, biogenic magnetite nanoparticles among
magnetic nanoparticles have unique attracted attention because of
their magnetic characteristics and potential applications in various
fields such as therapeutic and diagnostic. A well known example of
these biogenic nanoparticles is magnetosomes of magnetotactic
bacteria. In this research, we used two different types of technique for
the isolation and purification of magnetosome nanoparticles from the
isolated magnetotactic bacterial cells, heat-alkaline treatment and
sonication. Also we evaluated pyrogen content and sterility of
synthesized the isolated individual magnetosome by the Limulus
Amoebocyte Lysate test and direct impedimetric method
respectively.
Abstract: Recent advancements in sensor technologies and
Wireless Body Area Networks (WBANs) have led to the
development of cost-effective healthcare devices which can be used
to monitor and analyse a person-s physiological parameters from
remote locations. These advancements provides a unique opportunity
to overcome current healthcare challenges of low quality service
provisioning, lack of easy accessibility to service varieties, high costs
of services and increasing population of the elderly experienced
globally. This paper reports on a prototype implementation of an
architecture that seamlessly integrates Wireless Body Area Network
(WBAN) with Web services (WS) to proactively collect
physiological data of remote patients to recommend diagnostic
services. Technologies based upon WBAN and WS can provide
ubiquitous accessibility to a variety of services by allowing
distributed healthcare resources to be massively reused to provide
cost-effective services without individuals physically moving to the
locations of those resources. In addition, these technologies can
reduce costs of healthcare services by allowing individuals to access
services to support their healthcare. The prototype uses WBAN body
sensors implemented on arduino fio platforms to be worn by the
patient and an android smart phone as a personal server. The
physiological data are collected and uploaded through GPRS/internet
to the Medical Health Server (MHS) to be analysed. The prototype
monitors the activities, location and physiological parameters such as
SpO2 and Heart Rate of the elderly and patients in rehabilitation.
Medical practitioners would have real time access to the uploaded
information through a web application.
Abstract: Magnetic Nanoparticles (MNPs) have great potential
to overcome many of the shortcomings of the present diagnostic and
therapeutic approaches used in cancer diagnosis and treatment. This
Literature review discusses the use of Magnetic Nanoparticles
focusing mainly on Iron oxide based MNPs in cancer imaging using
MRI.
Abstract: This paper describes a methodology for remote
performance monitoring of retail refrigeration systems. The proposed
framework starts with monitoring of the whole refrigeration circuit
which allows detecting deviations from expected behavior caused by
various faults and degradations. The subsequent diagnostics methods
drill down deeper in the equipment hierarchy to more specifically
determine root causes. An important feature of the proposed concept
is that it does not require any additional sensors, and thus, the
performance monitoring solution can be deployed at a low
installation cost. Moreover only a minimum of contextual
information is required, which also substantially reduces time and
cost of the deployment process.
Abstract: Pattern recognition is the research area of Artificial Intelligence that studies the operation and design of systems that recognize patterns in the data. Important application areas are image analysis, character recognition, fingerprint classification, speech analysis, DNA sequence identification, man and machine diagnostics, person identification and industrial inspection. The interest in improving the classification systems of data analysis is independent from the context of applications. In fact, in many studies it is often the case to have to recognize and to distinguish groups of various objects, which requires the need for valid instruments capable to perform this task. The objective of this article is to show several methodologies of Artificial Intelligence for data classification applied to biomedical patterns. In particular, this work deals with the realization of a Computer-Aided Detection system (CADe) that is able to assist the radiologist in identifying types of mammary tumor lesions. As an additional biomedical application of the classification systems, we present a study conducted on blood samples which shows how these methods may help to distinguish between carriers of Thalassemia (or Mediterranean Anaemia) and healthy subjects.
Abstract: CT assessment of postoperative spine is challenging in the presence of metal streak artifacts that could deteriorate the
quality of CT images. In this paper, we studied the influence of different acquisition parameters on the magnitude of metal streaking.
A water-bath phantom was constructed with metal insertion similar with postoperative spine assessment. The phantom was scanned with
different acquisition settings and acquired data were reconstructed
using various reconstruction settings. Standardized ROIs were defined within streaking region for image analysis. The result shows
increased kVp and mAs enhanced SNR values by reducing image
noise. Sharper kernel enhanced image quality compared to smooth
kernel, but produced more noise in the images with higher CT fluctuation. The noise between both kernels were significantly
different (P