Abstract: Coronary artery bypass grafts (CABG) are widely
studied with respect to hemodynamic conditions which play
important role in presence of a restenosis. However, papers which
concern with constitutive modeling of CABG are lacking in the
literature. The purpose of this study is to find a constitutive model for
CABG tissue. A sample of the CABG obtained within an autopsy
underwent an inflation–extension test. Displacements were
recoredered by CCD cameras and subsequently evaluated by digital
image correlation. Pressure – radius and axial force – elongation
data were used to fit material model. The tissue was modeled as onelayered
composite reinforced by two families of helical fibers. The
material is assumed to be locally orthotropic, nonlinear,
incompressible and hyperelastic. Material parameters are estimated
for two strain energy functions (SEF). The first is classical
exponential. The second SEF is logarithmic which allows
interpretation by means of limiting (finite) strain extensibility.
Presented material parameters are estimated by optimization based
on radial and axial equilibrium equation in a thick-walled tube. Both
material models fit experimental data successfully. The exponential
model fits significantly better relationship between axial force and
axial strain than logarithmic one.
Abstract: We present a new method for the fully automatic 3D
reconstruction of the coronary artery centerlines, using two X-ray
angiogram projection images from a single rotating monoplane
acquisition system. During the first stage, the input images are
smoothed using curve evolution techniques. Next, a simple yet
efficient multiscale method, based on the information of the Hessian
matrix, for the enhancement of the vascular structure is introduced.
Hysteresis thresholding using different image quantiles, is used to
threshold the arteries. This stage is followed by a thinning procedure
to extract the centerlines. The resulting skeleton image is then pruned
using morphological and pattern recognition techniques to remove
non-vessel like structures. Finally, edge-based stereo correspondence
is solved using a parallel evolutionary optimization method based on
f symbiosis. The detected 2D centerlines combined with disparity
map information allow the reconstruction of the 3D vessel
centerlines. The proposed method has been evaluated on patient data
sets for evaluation purposes.
Abstract: It is believed that DNA damaging toxic metabolites contributes to the development of different pathological conditions. To prevent harmful influence of toxic agents, cells developed number of protecting mechanisms, such as enzymatic reaction of detoxification of reactive metabolites and repair of DNA damage. The aim of the study was to examine the association between polymorphism of GSTT1/GSTM1 and XRCC1/3 genes and coronary artery disease (CAD) incidence. To examine a polymorphism of these genes in CAD susceptibility in patients and controls, PCR based genotyping assay was performed. For GST genes, frequency of GSTM1 null genotype among CAD affected group was significantly increased than in control group (P0.1). We found that neither XRCC1 Arg399Gln nor XRCC3 Thr241Met were associated with CAD risk. Obtained data suggests that GSTM1 null genotype carriers are more susceptible to CAD development.
Abstract: Segmentation and quantification of stenosis is an
important task in assessing coronary artery disease. One of the main
challenges is measuring the real diameter of curved vessels.
Moreover, uncertainty in segmentation of different tissues in the
narrow vessel is an important issue that affects accuracy. This paper
proposes an algorithm to extract coronary arteries and measure the
degree of stenosis. Markovian fuzzy clustering method is applied to
model uncertainty arises from partial volume effect problem. The
algorithm employs: segmentation, centreline extraction, estimation of
orthogonal plane to centreline, measurement of the degree of
stenosis. To evaluate the accuracy and reproducibility, the approach
has been applied to a vascular phantom and the results are compared
with real diameter. The results of 10 patient datasets have been
visually judged by a qualified radiologist. The results reveal the
superiority of the proposed method compared to the Conventional
thresholding Method (CTM) on both datasets.