Abstract: Concrete Damaged Plasticity Model (CDPM) is capable of modeling the stress-strain behavior of confined concrete. Nevertheless, the accuracy of the model largely depends on its parameters. To date, most research works mainly focus on the identification and modification of the parameters for fiber reinforced polymer (FRP) confined concrete prior to damage. And, it has been established that the FRP-strengthened concrete behaves differently to FRP-repaired concrete. This paper presents a modified plastic damage model within the context of the CDPM in ABAQUS for modelling of a uniformly FRP-confined repaired concrete under monotonic loading. The proposed model includes infliction damage, elastic stiffness, yield criterion and strain hardening rule. The distinct feature of damaged concrete is elastic stiffness reduction; this is included in the model. Meanwhile, the test results were obtained from a physical testing of repaired concrete. The dilation model is expressed as a function of the lateral stiffness of the FRP-jacket. The finite element predictions are shown to be in close agreement with the obtained test results of the repaired concrete. It was observed from the study that with necessary modifications, finite element method is capable of modeling FRP-repaired concrete structures.
Abstract: Since columns are the most important elements of the
structures, failure of one column in a critical location can cause a
progressive collapse. In this respect, the repair and strengthening of
columns is a very important subject to reduce the building failure and
to keep the columns capacity. Twenty columns with different
parameters is tested and analysis. Eleven typical confined reinforced
concrete (RC) columns with different types of techniques are
assessment. And also, four confined concrete columns with plastic
tube (PVC) are tested with and with four paralleling tested of
unconfined plain concrete. The techniques of confined RC columns
are mortar strengthening, Steel rings strengthening, FRP
strengthening. Moreover, the technique of confined plain concrete
(PC) column is used PVC tubes. The columns are tested under
uniaxial compressive loads studied the effect of confinement on the
structural behavior of circular RC columns. Test results for each
column are presented in the form of crack patterns, stress-strain
curves. Test results show that confining of the RC columns using
different techniques of strengthening results significant improvement
of the general behavior of the columns and can used in construction.
And also, tested confined PC columns with PVC tubes results shown
that the confined PC with PVC tubes can be used in economical
building. The theoretical model for predicted column capacity is
founded with experimental factor depends on the confined techniques
used and the strain reduction.
Abstract: Lateral expansion is a factor defining the level of
confinement in reinforced concrete columns. Therefore, predicting
the lateral strain relationship with axial strain becomes an important
issue. Measuring lateral strains in experiments is difficult and only
few report experimental lateral strains. Among the existing analytical
formulations, two recent models are compared with available test
results in this paper with shortcomings highlighted. A new analytical
model is proposed here for lateral strain axial strain relationship and
is based on the supposition that the concrete behaves linear elastic in
the early stages of loading and then nonlinear hardening up to the
peak stress and then volumetric expansion. The proposal for the
lateral strain axial strain relationship after the peak stress is mainly
based on the hypothesis that the plastic lateral strain varies linearly
with the plastic axial strain and it is shown that this is related to the
lateral confinement level.